MetroSelect™ Configuration Guide MLPN 2407/February 2000
i MetroSelect™ Locations USA Corporate Headquarters Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012-4683 Tel: 856-228-8100 Fax: 856-228-6673 Email: info@metrologic.com www.metrologic.com Brazil Metrologic do Brasil Ltda. Rua Flórida, 1821-5˚Andar São Paulo, SP, Brasil CEP: 04571-090 Tel: 5511-5505-2396 Fax: 5511-5507-2301 Email: info@br.metrologic.com Europe Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b.
MetroSelect™ Table of Contents Introduction iii Section A: Code Types & Decode Rules A Section B: Supplements B Section C: Communications C Section D: Scanner Operation D Section E: Prefixes/Suffixes E Section F: Code Formatting F Section G: RS-232 G Section H: Keyboard H Section I: OCIA I Section J: Light Pen Parameters J Section K: IBM 46xx K Section L: MS9500 Voyager™ L Section M:Code Bytes M Section N: Miscellaneous Features N ii
iii MetroSelect™ Introduction Your new scanner has been configured at the factory with default settings. Many host systems have unique formats and protocol requirements. Therefore, Metrologic provides a wide range of configurable features that may be selected using this bar code based configuration tool. Once the configuration is completed, the scanner stores the settings in nonvolatile memory (NOVRAM). NOVRAM saves the settings when the power is turned off.
MetroSelect™ Bar Code Configuration Methods Single Code Method 1. Power up scanner 2. Scan the bar code for the desired feature 3. Observe a “good scan” beep, quickly followed by a multi-toned, “save setting” beep. Multi-Code Method 1. Power up scanner 2. Scan Enter/Exit Configuration Mode bar code (3 beeps) 3. Scan bar code for the desired feature (1 beep) 4. Scan Enter/Exit Configuration Mode bar code (3 beeps) and save new configuration.
v MetroSelect™ Need to start over? Use the Recall Default bar code. This will erase all previous settings and return to the scanner’s default communications protocol. -Keyboard Wedge interface scanners will load keyboard wedge defaults. -All other scanners load RS-232 defaults. Note: Metrologic manufactures custom OEM scanners which load the OEM’s defaults. Section N will explain how this affects “Metrologic Defaults.
MetroSelect™ Section A Code Types and Decode Rules UPC-EAN A-1 Code 128 A-3 Code 39 A-4 Interleaved 2 of 5 A-6 Standard 2 of 5 A-8 Other 2 of 5 Codes A-9 Codabar A-10 Code 93 A-11 Code 11 A-11 Telepen A-12 Plessey Codes A-13 Other Decode Features A-15 Configurable Code Lengths A-16 A
A-1 MetroSelect™ UPC/EAN *Enable UPC/EAN 100116 Disable UPC/EAN 100106 *Enable UPC-A 100216 Disable UPC-A 100206 *Enable UPC-E 100210 Disable UPC-E 100200
MetroSelect™ *Enable EAN-13 100211 Disable EAN-13 100201 *Enable EAN-8 100214 Disable EAN-8 100204 A-2
A-3 MetroSelect™ Code 128 *Enable Code 128 100113 Enable UCC/EAN - 128 ‘]C1’ Code formatting 100314 For Coupon Code 128, see Section B.
MetroSelect™ Code 39 Disable Code 39 *Enable Code 39 100111 100101 Enable MOD 43 Check on Code 39 100213 *Disable MOD 43 Check on Code 39 100203 When enabled, the scanner will only scan Code 39 bar codes that have a valid Modulo 43 check digit. Enable Full ASCII Code 39 100217 The scanner will not test Code 39 bar codes for a Modulo 43 check digit.
A-5 MetroSelect™ Enable PARAF (Italian Pharmaceutical Codes) Support 100215 When enabled, the scanner will convert Code 39 bar codes to PARAF format. Enable TRI-OPTIC Code 100312 *Disable PARAF Support 100205 When disabled, the scanner will not convert Code 39 bar codes to PARAF format.
MetroSelect™ Interleaved 2 of 5 *Enable Interleaved 2 of 5 (ITF) Disable Interleaved 2 of 5 (ITF) 100105 100115 Enable MOD 10 Check on ITF *Disable MOD 10 Check on ITF 100310 100300 When option enabled, the scanner will only scan Interleaved 2 of 5 (ITF) bar codes that have a Modulo 10 check digit. When option disabled, the scanner will not test Interleaved 2 of 5 (ITF) bar codes for a Modulo 10 check digit.
A-7 MetroSelect™ ~ITF Symbol Length Lock 1 ~ITF Symbol Length Lock 2 901600 901700 To specify a First ITF symbol length lock, scan the above bar code and the appropriate code bytes located in Section M. Refer to Multi Code Method on page iii. To specify a second ITF symbol length lock, scan the above bar code and the appropriate code bytes located in Section M. Refer to Multi Code Method on page iii.
MetroSelect™ Standard 2 of 5 Enable Standard 2 of 5 100110 *Disable Standard 2 of 5 100100 ~Standard 2 of 5 Symbol Length 901500 To specify a minimum number of ITF characters to be decoded, scan the above bar code and the appropriate code bytes located in Section M. Refer to Multi Code Method on page iii.
A-9 MetroSelect™ Other 2 of 5 Codes Enable Matrix 2 of 5 *Disable Matrix 2 of 5 100005 100015 Enable 15 Digit Airline 2 of 5 *Disable 15 Digit Airline 2 of 5 100004 100014 *Disable 13 Digit Airline 2 of 5 Enable 13 Digit Airline 2 of 5 100313 100303
MetroSelect™ Enable Hong Kong 2 of 5 *Disable Hong Kong 2 of 5 100306 100316 Codabar *Enable Codabar Disable Codabar 100104 100114 Enable Dual Field Codabar *Disable Dual Field Codabar 100002 100012 A-10
A-11 MetroSelect™ Code 93 *Enable Code 93 Disable Code 93 100102 100112 Code 11 Enable Code 11 100013 *Disable Code 11 100003
MetroSelect™ Telepen Enable Telepen *Disable Telepen 100007 100017 Enable ALPHA Telepen *Disable ALPHA Telepen 100006 100016 A-12
A-13 MetroSelect™ Plessey Codes Enable MSI Plessey *Disable MSI Plessey 100202 100212 *No MSI Plessey Check Digit 200704 This option will not test MSI Plessey bar codes for a check digit. Enable MSI Plessey MOD 10/10 Check Digit *Enable MSI Plessey Mod 10 Check digit 200734 200724 Test MSI Plessey bar codes for a double Modulo 10 check digit. Test MSI Plessey bar codes for a single Modulo 10 check digit.
MetroSelect™ Enable UK Plessey *Disable UK Plessey 100107 100117 UK Plessey A to X Conversion Enabled *UK Plessey A to X Conversion Disabled 100716 100706 Enables UK Plessey A to X Conversion. Disables UK Plessey A to X Conversion.
A-15 MetroSelect™ Other Decode Features Enable Double Border Required/Large Intercharacter Space 100011 *Disable Double Border Required/Large Intercharacter Space 100001 ~Minimum Symbol Length ~Symbol Length Lock 901800 901900 Omnidirectional default is 4. Single-line default is 3. Combine this code with the proper Code Bytes, to specify the minimum number of characters in all non-UPC/EAN bar codes. Refer to Multi-Code Method on page iii.
MetroSelect™ Configurable Code Lengths There are seven bar code lock lengths available. Specific code types can be assigned to a lock length. While in programming mode, start with lock length 1, then scan three Code Byte bar codes from Section M that represent the bar code length. (A table with the code type values can be found in Section M) Refer to Multi-Code Method on page iii. This process can be repeated for lock lengths 2 through 7.
A-17 MetroSelect™ ~Code Lock #3: Length 902400 ~Code Lock #3: Code Type 902500 ~Code Lock #4: Length 902600 ~Code Lock #4: Code Type 902700 ~Code Lock #5: Length 902800 ~Code Lock #5: Code Type 902900
MetroSelect™ ~Code Lock #6: Length 903000 ~Code Lock #6: Code Type 903100 ~Code Lock #7: Length 903200 ~Code Lock #7: Code Type 903300 A-18
MetroSelect™ Section B Supplements Two Digit Supplements B-1 Two Digit Redundancy B-1 Five Digit Supplements B-1 Five Digit Redundancy B-2 Supplements Required/Not Required B-2 Remote Supplemental Requirement B-2 Bookland (978) Supplement Requirement B-3 977 (2 digit) Supplement Requirement B-3 378/379 French Supplement Requirement B-3 434/439 German Supplement Requirement B-4 #System 2 Requires Supplements B-4 #System 5 Requires Supplements B-4 Coupon Code 128 B-5 Code 128 ‘]C1’ E
B-1 MetroSelect™ Supplements Enable Two Digit Supplements 101217 *Enable Two Digit Redundancy *Disable Two Digit Supplements 101207 Disable Two Digit Redundancy 101212 101202 Twice before accepting data, the scanner will scan the bar code plus the 2 digit add on. When Scanned, will not implement the two digit redundancy feature.
MetroSelect™ *Disable Five Digit Redundancy Enable Five Digit Redundancy 101211 101201 Twice before accepting data, the scanner will scan the bar code plus the five digit add on. When Scanned, will not implement the five digit redundancy feature. Supplements are Required *Supplements are not Required 101213 101203 When chosen, all UPC/EAN labels that are scanned must have a supplement. When chosen, all UPC/EAN labels do not require a supplement to be scanned.
B-3 MetroSelect™ Enable Bookland (978) Supplement Requirement 101417 Enable 977 (2 digit) Supplemental Requirement *Disable Bookland (978) Supplement Requirement 101407 *Disable 977 (2 digit) Supplemental Requirement 101314 101304 When enabled, the scanner will require a 2 digit supplement be scanned whenever an EAN-13 code begins with 977. When enabled, the scanner will not require a 2 digit supplement be scanned whenever an EAN-13 code begins with 977.
MetroSelect™ Enable 434/439 German Supplemental Requirement *Disable 434/439 German Supplemental Requirement 101415 101405 Enable #System 2 Requires Supplements *Disable #System 2 Requires Supplements 101412 101402 Enable #System 5 Requires Supplements *Disable #System 5 Requires Supplements 101215 101205 B-4
B-5 MetroSelect™ Enable Coupon Code 128 100315 Enable Code 128 ‘]C1’ Extended Code Format *Disable Coupon Code 128 100305 *Disable Code 128 ‘]C1’ Extended Code Format 101411 101401 When enabled, scanner transmits an ‘]C1’ at the beginning of the Code 128 portion of the coupon code. When disabled, scanner will not transmit on ‘]C1’ at the beginning of the Code 128 portion of the coupon code.
MetroSelect™ 400 msec to Find Supplemental 200 msec to Find Supplemental 301340 301320 With this option, the scanner will allot 400 milliseconds to “find” an add on after a main UPC/EAN bar code has been scanned. With this option, the scanner will allot 200 milliseconds to “find” an add on after a main UPC/EAN bar code has been scanned. *100 msec to Find Supplemental 301310 With this option, the scanner will allot 100 milliseconds to “find” an add on after a main UPC/EAN bar code has been scanned.
B-7 MetroSelect™ Enable Code ID’s with Supplements 101214 *Beep Once on Supplements 118406 *Disable Code ID’s with Supplements 101204 Beep Twice on Supplements 118416
MetroSelect™ Enable ISBN Check Digit Transmission Disable ISBN Check Digit Transmission 101315 101305 Not available with all models. *Disable Bookland to ISBN Conversion Enable Bookland to ISBN Conversion 101317 101307 Not available with all models. *Disable ISBN Re-Formatting Enable ISBN Re-Formatting 101316 101306 Not available with all models.
B-9
MetroSelect™ Section C Communications Enable Light Pen/Wand Communication C-1 Enable RS-232 C-1 Load Keyboard Wedge Defaults C-1 Enable Stand-Alone Keyboard Scanner C-1 Enable Keyboard Wedge Emulation C-1 Enable OCIAOutput C-2 Load OCIA Defaults C-2 Enable IBM 46xx Communication C-2 Load IBM 46xx IBM Defaults C-2 Enable No Communication Mode C-3 Reserved C-3 Reserved C-3 C
C-1 MetroSelect™ Communications Enable Light Pen/Wand Communication 415524 Use this option if scanner should be used in place of a light pen. *Enable RS-232 415554 When this option is enabled, the scanner will work with RS-232 +/-12V serial output. Load Keyboard Wedge Defaults 999994 Scan this before selecting Normal or Stand Alone Mode. Enable Stand-Alone Keyboard Scanner Enable Keyboard Wedge Emulation 5155143 5155153 Allows scanner to be used without an external keyboard.
MetroSelect™ Enable OCIA Output Load OCIA Defaults 415544 999993 Select this option if the communications requirement is an Optically Coupled Interface Adapter (OCIA). This a clocked (by the host) serial interface. Scan this before selecting Enable OCIA output Enable IBM 46xx Communication Load IBM 46xx Defaults 415504 999995 Select this option for IBM 46XX SIOC/RS485 communications. Not all scanners support this interface. The correct interface board is required.
C-3 MetroSelect™ Enable No Communication Mode 415534 Select this option if the scanner does not interface with the host device.
MetroSelect™ Section D Scanner Operation Configuration Mode Options D-1 Scan Buffers D-2 Redundant Scans D-4 Miscellaneous Decode Features D-6 Depth of Field Adjustments D-7 Same Symbol Time Outs D-8 LED Options D-10 Beeper Options D-11 Data Transmission Delays D-14 Inter-Character D-14 Inter-Record D-15 Communication Timeout Options D-16 Host Scanner Commands D-18 Power Save Modes D-22 Miscellaneous Features D-24 Test Modes D-25 D
D-1 MetroSelect™ Configuration Mode Allow Configuration Mode on Power-Up *Allow Configuration Mode Anytime 118117 118107 Scanner can only enter MetroSet™ mode before any bar codes are scanned. Allow MetroSet™ configuration at any time. Allow Configuration Labels on Power-up *Allow Configuration Labels Anytime 118116 118106 Once a product bar code is scanned after power-up, the scanner will not accept configuation bar codes. Allows scanning of configuration bar codes any time.
MetroSelect™ Scan Buffers 2 Scan Buffers *1 Scan Buffer 318000 318010 When enabled, the scanner will scan one bar code in the scan field and not scan again until the bar code is removed from the scan field for the duration of the same symbol time out. When enabled, the scanner will scan 2 bar codes in the scan field one time each. These 2 bar codes will not be scanned again until they are removed from the scan field for the duration of the same symbol time out.
D-3 MetroSelect™ 7 Scan Buffers 8 Scan Buffers 318060 318070 Same function as 2 Scan Buffers, but 7 bar codes are in the scan field. Same function as 2 Scan Buffers, but 8 bar codes are in the scan field.
MetroSelect™ Redundant Scans *0 Redundant Scans 1 Redundant Scans 301100 301110 Requires 1 good decode for a “good scan.” Requires 2 consecutive decodes of the same bar code data for a “good scan” . 2 Redundant Scans 3 Redundant Scans 301120 301130 Requires 3 consecutive... Requires 4... 4 Redundant Scans 5 Redundant Scans 301140 301150 Requires 5... Requires 6...
D-5 MetroSelect™ 6 Redundant Scans 7 Redundant Scans 301160 301170 Requires 7... Requires 8...
MetroSelect™ Miscellaneous Decode Features *Enable MAJIC Disable MAJIC 101113 101103 The Metrologic Algorithm for Joining Incomplete Codes (MAJIC) aids in deciphering damaged or incomplete bar codes. Enable for more aggressive decoding. Disable this feature when bar codes are in good reading condition. This will speed up decoding and improve over all accuracy.
D-7 MetroSelect™ Depth of Field Adjustments Do not change these settings unless instructed by a Metrologic representative. *Optimize for Low Density Codes Optimize for High Density Codes 418790 4187130 For use with omnidirectional scanners only. For use with omnidirectional scanners only. Fixed for High Density Codes Fixed for Medium Density 418700 418710 For use with omnidirectional scanners only. For use with omnidirectional scanners only.
MetroSelect™ Same Symbol Time outs These numbers determine the length of time before a bar code can be rescanned after it is removed from the scan field. Single code fixed settings in msecs of No, 50, 100, 200, 500,1200 (1.2 sec), 2000 (2.0 sec) and infinite are available. Also, user-configurable value can be set in user-configurable increments of 50 for a range of 50 msecs to 6350 (6.35 sec). If using the MS9500 series, please go to Section L.
D-9 MetroSelect™ Infinite Same Symbol Time Out ~Variable Same Symbol Timeout 118917 918900 When selected, the scanner will not repetitively scan the same bar code. This option overrides the symbol rescan time-outs. In configuration mode, scan this bar code and a code byte sequence from Section M to set the same symbol time out duration. Values range from 001 to 127 (50 to 6350 msecs). Refer to MultiCode Method on page iii.
MetroSelect™ LED Options Flash Green LED if Rescan Allowed *Do Not Flash Green LED if Rescan Allowed 118313 118303 This indicates same symbol timeout has elapsed.
D-11 MetroSelect™ Beeper Options *Normal Tone 318575 Optional Tone 1 318565 Optional Tone 2 318555 Optional Tone 3 318545 Optional Tone 4 318535 Optional Tone 5 318525
MetroSelect™ Optional Tone 6 No Beep 318515 318505 Beep Twice on Supplements *Beep Once on Supplements 118406 118416 Enable Fast Beep *Disable Fast Beep 118414 118404 D-12
D-13 MetroSelect™ *Ignore BEL Command Beep on BEL Command 118417 118407 The scanner beeps when it receives a BEL character from the host. If a number is sent within 200 msecs before the BEL character, the scanner will beep that number of times. Enable Light Pen Toggle During Beep 116913 When enabled, the scanner beeps and toggles the light pen data line on a successful decode. This drives a good read indicator.
MetroSelect™ Data Transmission Delays Use these codes to select the amount of delay between sending data characters and “Bar code” Records from the scanner to the host. This helps prevent the scanner from overflowing host input buffers.
D-15 MetroSelect™ No Intercharacter Delay 818800 Inter-Record Delay ~Variable Inter-Record Delay 919300 Turn Off Laser During InterRecord Delay 119317 *Leave Laser On During Inter-Record Delay 119307
MetroSelect™ Communication Timeout Options Enable Communications Time Outs *Disable Communications 118412 118402 Beep After Transmit *Beep Before Transmit 118413 118403 Scanner will beep after each label is transmitted. Scanner will beep after each label is transmitted.
D-17 MetroSelect™ Short Communications Time Out (1 secs) 8191200 Long Communications Time Out (4 secs) 8191800 Three Beeps on Time Out 118410 Razzberry Tone on Time Out 118411 *No Beeps on Time Out 118400 *No Razzberry Tone on Time Out 118401
MetroSelect™ Host Scanner Commands Enable “D/E” Disable Command *Disable “D/E” Disable 118115 118105 When this option is chosen, the scanner will disable scanning after it receives an ASCII “D” from the host device. It will enable scanning when it receives an ASCII “E.” Do not monitor D/E commands. Enable Z/R Type D/E Simulation *No “Z/R” Type “D/E” Simulation 118211 118201 When this option is chosen, the scanner will disable scanning after it receives an ASCII “Z” from the host device.
D-19 MetroSelect™ Enable “F/L” Laser Command *Disable “F/L” Laser Command 118014 118004 When enabled, the scanner will turn off the laser after the scanner receives an ASCII “F” character. The laser will turn on after it receives an ASCII “L” character. Do not monitor “F/L” commands. Motor On/Off Using M/O Commands *Disable M/O Commands 118213 118203 When enabled, the motor will turn on after the scanner receives an ASCII “M” character.
MetroSelect™ Use DTRScan Disable *Do not use DTRScan Disable 118115 118105 When enabled, the scanner will monitor the DTR input to determine if scanning should be allowed. A +12V “active” level enables decoding. A -12V “inactive” level disables decoding. Do not monitor the DTR input.
D-21 MetroSelect™ Activate on DC2 Character 118110 Transmit “NO READ” if DC2 Activated 118111 No Green LED During “NO READ” Xmit 118311 *Do Not Activate on DC2 Character 118100 Do Not Transmit “NO READ” if DC2 Activated 118101 *Green LED During “NOREAD” Xmit 118301
MetroSelect™ Power Save Modes Always Power Save Mode No Power Save Mode 118617 818600 Enters power save mode immediately after power-up and after each bar code scanned. For use with Omnidirectional scanners only. The scanner will never enter power save mode. For use with Omnidirectional scanners only. Power Save Mode in 1 Minute Power Save in 2 Minutes 118610 818620 Enters power save mode when the scanner remains idle for 1 minute. For use with Omnidirectional scanners only.
D-23 MetroSelect™ Power Save in 5 Minutes Power Save in 10 Minutes 8186100 818650 Enters power save mode if the scanner remains idle for 5 minutes. For use with Omnidirectional scanners only. Enters power save mode if the scanner remains idle for 10 minutes. For use with Omnidirectional scanners only. Power Save in 30 Minutes Power Save in 20 Minutes 8186200 8186300 Enters power save mode if the scanner remains idle for 20 minutes. For use with Omnidirectional scanners only.
MetroSelect™ Miscellaneous Features Enable Japan Mode *Disable Japan Mode 118112 118102 D-24
D-25 MetroSelect™ Test Modes 118017Scanability ON *Scanability OFF 118007 118017 118007 This option enters scanability test mode. Do not enable unless instructed by a Metrologic representative. Scan Count Mode ON 118016 When enabled, the scanner will enter scan count test mode and the scanner’s firmware number will transmit to the host. Do not enable unless instructed by a Metrologic representative.
MetroSelect™ Section E Prefixes/Suffixes User Configurable Prefixes, All Data E-1 User Configurable ID Characters, Code Specific E-3 Standard Prefix Characters E-8 Standard Suffix Characters E-13 Longitudinal Redundancy Check (LRC) E-15 User Configurable Suffixes, All Data E-16 Special Formats E-19 E
E-1 MetroSelect™ User Configurable Prefixes, All Data Note: Scan “Enter configuration mode” code before trying to set this feature. Please refer to MultiCode Method pn page iii. ~Configurable Prefix Character #1 ~Configurable Prefix Character #2 903500 903600 When this option is chosen, a prefix ID can be added and assigned for data transmission. Use this code with a 3 code byte sequence from Section M that represents the desired character. Assigns a second configurable prefix character.
MetroSelect™ ~Configurable Prefix Character #7 ~Configurable Prefix Character #8 904100 904200 Assigns a seventh configurable prefix character. Assigns an eighth configurable prefix character. ~Configurable Prefix Character #10 ~Configurable Prefix Character #9 904300 904400 Assigns a ninth configurable prefix character. Assigns a tenth configurable prefix character.
E-3 MetroSelect™ User Configurable ID Characters, Code Specific *Use Configurable Code ID Bytes as Prefixes Use Configurable Code ID Bytes as Suffixes 105507 105517 User configured, code specific ID bytes are transmitted before the data. If using prefixes, user configured suffixes can not be used. User configured, code specific ID bytes are transmitted after the data. If using suffixes, user configured prefixes can not be used.
MetroSelect™ Configurable EAN-8 ID Configurable EAN-13 ID 905800 905900 While in using the MultiCode Method, scan this bar code followed by the 3 code byte bar codes in Section M that represent a unique ID character to be associated with this bar code type. Please refer to MultiCode Method on page iii. While in using the MultiCode Method, scan this bar code followed by the 3 code byte bar codes in Section M that represent a unique ID character to be associated with this bar code type.
E-5 MetroSelect™ Configurable Code 93 ID Configurable Code 11 ID 906300 906400 While in using the MultiCode Method, scan this bar code followed by the 3 code byte bar codes in Section M that represent a unique ID character to be associated with this bar code type. Please refer to MultiCode Method on page iii. While in using the MultiCode Method, scan this bar code followed by the 3 code byte bar codes in Section M that represent a unique ID character to be associated with this bar code type.
MetroSelect™ Configurable Interleaved 2 of 5 ID Configurable Standard 2 of 5 ID 907100 906700 While in using the MultiCode Method, scan this bar code followed by the 3 code byte bar codes in Section M that represent a unique ID character to be associated with this bar code type. Please refer to MultiCode Method on page iii.
E-7 MetroSelect™ Configurable UK Plessey ID Configurable MSI Plessey ID 906500 907000 While in using the MultiCode Method, scan this bar code followed by the 3 code byte bar codes in Section M that represent a unique ID character to be associated with this bar code type. Please refer to MultiCode Method on page iii. While in using the MultiCode Method, scan this bar code followed by the 3 code byte bar codes in Section M that represent a unique ID character to be associated with this bar code type.
MetroSelect™ Standard Prefix Characters Enable STX Prefix *Disable STX Prefix 116615 116605 When enabled, the scanner will transmit a Start of TeXt (ASCII 02H) before each bar code. Will not transmit a Start of TeXt (ASCII 02H) before each bar code. Enable Rochford-Thomson Mode *Disable Rochford-Thomson Mode 105513 105503 *Disable AIM ID Characters Enable AIM ID Characters 107915 107905 The scanner will transmit AIM symbology identifiers.
E-9 MetroSelect™ Enable UPC Prefix ID *Disable UPCPrefix ID 116617 116607 When enabled, the scanner will transmit a prefix before any UPC/EAN bar code. The prefixes are A (UPC-A), E0 (UPC-E), F (EAN-13), and FF (EAN-8). Do not send prefix ID Characters with UPC/EAN codes. Enable NCR Prefix ID 107911 When enabled, the scanner will transmit a prefix before the following code types.
MetroSelect™ Enable Nixdorf ID Characters *Disable Nixdorf ID Characters 107917 107907 When enabled, this option transmits code identifiers before each bar code for many Siemens/Nixdorf registers. This bar code will not transmit Siemens/Nixdorf code identifiers. Enable SANYO ID Characters *Disable SANYO ID Characters 107916 107906 Transmit Sanyo ID Characters. Do not transmit Sanyo ID Characters.
E-11 MetroSelect™ Enable Manufacturer ID Prefix *Disable Manufacturer ID Prefix 105512 105502 Transmits “METROLOGIC” before all bar code data to identify the scanner as a Metrologic scanner. Will not transmit the identification string.
MetroSelect™ Enable Tab Prefix *Disable Tab Prefix 116611 116601 The Scanner will transmit a TAB (ASCII 09H) before each bar code. Will not transmit a TAB.
E-13 MetroSelect™ Standard Suffix Characters Disable CR Suffix *Enable CR Suffix 116613 116603 When enabled, the scanner transmits a Carriage Return after each bar code. The scanner will not transmit a Carriage Return after each bar code. *Enable LF Suffix Disable LF Suffix 116612 116602 When enabled, the scanner transmits a Line Feed after each bar code. Note: Disabled when keyboard wedge defaults are loaded. The scanner will not transmit a Line Feed after each bar code.
MetroSelect™ Enable ETX Suffix *Disable ETX Suffix 116614 116604 When enabled, the scanner will transmit End of TeXt (ASCII 03H) after the bar code data. When disabled, the scanner will not transmit End of TeXt (ASCII 03H). Enable UPC Suffix ID *Disable UPC Suffix ID 116616 116606 When enabled, the scanner will transmit a suffix after any UPC/EAN bar code. The suffixes are A (UPCA), E (UPC-E), F (EAN-13) and F (EAN-8). Will not transmit a suffix after UPC/EAN bar codes.
E-15 MetroSelect™ Longitudinal Redundancy Check (LRC) Enable Transmit of LRC Calculation *Disable Transmit of LRC Calculation 107811 107801 With this option, the scanner outputs an LRC check character after the bar code. Will not output an LRC (check character) after the bar code. Start LRC on Second Byte *Start LRC on First Byte 107810 107800 The scanner will calculate the LRC check digit starting with the second character.
MetroSelect™ User Configurable Suffixes, All Data Note: Scan “Enter configuration mode” code before trying to set this feature. Refer to MultiCode Method on page iii. ~Configurable Suffix Character #1 ~Configurable Suffix Character #2 904500 904600 When chosen, a suffix ID can be added and assigned for data transmission. Use this code with a 3 code byte sequence from Section M that represents the desired character. Assigns a second configurable suffix character.
E-17 MetroSelect™ ~Configurable Suffix Character #5 ~Configurable Suffix Character #6 904900 905000 Assigns a fifth configurable suffix character. Assigns a sixth configurable suffix character. ~Configurable Suffix Character #7 ~Configurable Suffix Character #8 905100 905200 Assigns a seventh configurable suffix character. Assigns an eighth configurable suffix character.
MetroSelect™ *Clear All User Configurable Suffixes 999984 E-18
E-19 MetroSelect™ Special Formats Enable SINEKO Mode 107914 Enable Newcode Formatting Mode A 116711 Enable Newcode Formatting Mode B 116710 *Disable SINEKO Mode 107904 *Disable Newcode Formatting Mode A 116701 *Disable Newcode Formatting Mode B 116700
MetroSelect™ Section F Code Formatting UPC-EAN Formatting Codabar Formatting Code 39 Formatting Code 11 Telepen Plessey 2 of 5 Code Formatting F-1 F-5 F-6 F-7 F-7 F-8 F-9 F
F-1 MetroSelect™ UPC/EAN Formatting *Transmit UPC-A Check Digit 116617 Do Not Transmit UPC-A Check Digit 116607 Transmit UPC-E Check Digit 107516 *Do Not Transmit UPC-E Check Digit 107506 Expand UPC-E to 12 Digits *Do Not Expand UPC-E to 12 Digits 107515 107505 Expand UPC-E bar codes to the 12 digit equivalent, UPC-A bar codes. Do not expand UPC-E to the 12 digit equivalent, UPC-A bar code.
MetroSelect™ Convert UPC-A to EAN-13 *Do Not Convert UPC-A to EAN-13 107514 107504 With this option, the scanner converts UPC-A to EAN-13 by transmitting a leading zero before the bar code. With this option, the scanner will not convert UPC-A to EAN-13. Transmit Lead Zero on UPC-E Do Not Transmit Lead Zero on UPC-E 107513 107503 When chosen, this option will transmit a zero before each UPC-E bar code This option will not transmit a zero before each UPC-E bar code.
F-3 MetroSelect™ *Transmit UPC-A Number System 107511 Do Not Transmit UPC-A Number System 107501 Metrologic strongly discourages using this feature. Duplicate numbers may result in the database.
MetroSelect™ *Transmit EAN-8 Check Digit 107910 Do Not Transmit EAN-8 Check Digit 107900 Do Not Transmit EAN-13 Check Digit *Transmit EAN-13 Check Digit 107912 107902 Scanner will transmit EAN-13 Check Digit. Scanner will not transmit EAN-13 Check Digit.
F-5 MetroSelect™ Codabar Formatting Transmit Codabar Start/Stop Characters 107717 *Do Not Transmit Codabar Start/Stop 107707 Transmits Codabar’s start/stop characters before and after each bar code. Will not transmit Codabar’s start/stop characters before and after each bar code. Enable CLSI Editing 107716 Works only with 14 digit Codabar type lengths. This option will perform CLSI type editing before the information is transmitted to the host.
MetroSelect™ Code 39 Formatting Transmit Mod 43 Check Digit On Code 39 *Do Not Transmit Mod 43 Check Digit On Code 39 107715 107705 This feature works in conjunction with Mod 43 Check on Code 39 option in section A. Both must be enabled for this feature to work. This option will not transmit Code 39’s Mod 43 check character.
F-7 MetroSelect™ Code 11 Transmit Code 11 Check Digit *Do Not Transmit Code 11 Check Digit 107713 107703 This bar code will transmit Code 11 check characters when used with Enabled Code 11 in section A. This bar code will not transmit Code 11 check characters.
MetroSelect™ Plessey Transmit UK Plessey Check Digit *Do Not Transmit UK Plessey Check Digit 107816 107806 The scanner will transmit UK Plessey Check Digit characters and must be used with the UK Plessey option. Will not transmit UK Plessey Check Digit characters.
F-9 MetroSelect™ 2 of 5 Code Formatting Transmit Mod 10 Check Digit on ITF *Do not Transmit Mod 10 Check Digit on ITF 107714 107704 With this option, the scanner transmits Interleaved 2 of 5 (ITF) Mod 10 check character. The scanner will not transmit Interleaved 2 of 5 (ITF) Mod 10 check character. Works in conjunction with Mod 10 check on ITF. Both must be enable for this feature to work.
MetroSelect™ Section G RS-232 Enable RS-232 G-1 Parity Features G-2 BAUD Rate Features G-3 Data/Stop Bit Features G-5 Hardware Handshaking G-6 Software Handshaking G-9 Miscellaneous G-11 G
G-1 MetroSelect™ *Enable RS-232 Mode 415554 When enabled the scanner will work with RS-232 +/-12V serial output.
MetroSelect™ Parity Features A parity bit is an extra data bit used to help catch data transmission errors. The scanner’s parity must match the host’s parity. No Parity 316045 Odd Parity *Space Parity 316005 316015 Select Odd Parity to set the parity bit to either a 1 or a 0 to ensure an odd number of bits are 1’s. Select Space Parity to set the parity bit always 0.
G-3 MetroSelect™ BAUD Rate A “BAUD” or “BAUD Rate” is the speed at which data is transmitted. Select a BAUD for the scanner that matches the host device. 57600 BAUD Rate 115200 BAUD Rate 4158100 415890 Not supported on the MS9500 Voyager.™ Not supported on the MS9500 Voyager.
MetroSelect™ 4800 BAUD Rate 415840 2400 BAUD Rate 415830 600 BAUD Rate 1200 BAUD Rate 415820 415810 300 BAUD Rate 415800 G-4
G-5 MetroSelect™ Data/Stop Bits *7 Data Bits 8 Data Bits 116013 116003 Number of data bits transmitted for each character.
MetroSelect™ Hardware Handshaking Enable RTS/CTS Handshaking *Disable RTS/CTS Handshaking 115816 115806 Output a Request To Send (RTS) signal and wait for a Clear To Send (CTS) signal before transmitting data. Do not use RTS/CTS handshaking. Message RTS/CTS *Character RTS/CTS 115815 115805 Activate/Deactivate RTS signal for each character. Activate RTS before sending the first character and leave it active until after the last character has been transmitted.
G-7 MetroSelect™ Invert CTS Polarity (RSV2) *Standard CTS Polarity 124511 124501 +12v = Inactive, do not send -12v = Active, OK to send -12v = Inactive, do not send +12v = Active, OK to send Activate RTS, Do Not wait for CTS (RSV3) *Activate RTS, Wait for CTS 124512 124502 Activate RTS for transmission but, do not wait for CTS to send. Wait for CTS after activating RTS.
MetroSelect™ Enable DTR Support 115817 *Disable DTR Support 115807 When enabled the scanner will stop scanning when the Data Terminal Ready (DTR) signal goes inactive. Enable RTS Counter Toggle 115915 *Disable RTS Counter Toggle 115905 The scanner will toggle the RTS line on a good decode.
G-9 MetroSelect™ Software Handshaking Enable XON/XOFF Handshaking *Disable XON/XOFF Handshaking 115914 115904 When enabled, the scanner will stop transmission whenever an XOFF (ASCII 13H) is received. Transmission will resume after an XON (ASCII 11H) is received. The scanner will not test for XON/XOFF. *Disable ACK/NAK Enable ACK/NAK 115913 115903 After transmitting data, wait for an ACK (06H) or a NAK (15H) response from the host.
MetroSelect™ Support BEL/CAN in ACK/NAK *Ignore BEL/CAN in ACK/NAK 115911 115901 When BEL (07H) is received, the scanner beeps 3 times and exits the communications loop. If a CAN (18H) is received, then the scanner will exit the communications loop, silently. Ignore BEL/CAN characters in communication loop. Enable 5 Retries on ACK/NAK Time Out *Disable 5 Retries on ACK/NAK Time Out 118013 118003 Allow up to 5 NAK retransmissions of the data before dropping out of the communications loop.
G-11 MetroSelect™ Miscellaneous Enable French PC Term 116110 When enabled, the scanner transmits PC type make/break scan codes instead of ASCII data characters. The scan codes match a WYSE French PC Term Terminal Emulation. *Disable French PC Term 116100 Do not transmit in French PC Term mode.
MetroSelect™ Section H Keyboard Enable Keyboard Emulations H-1 Country/Scan Code Table Selects H-2 Keyboard/System Type H-4 Special Keyboard Features H-5 InterScan Code Delays H-8 Control Sets H-9 H
H-1 MetroSelect™ Enable Keyboard Emulation Load Keyboard Wedge Defaults 999994 Loads default settings for keyboard wedge mode. Enable Stand-Alone Keyboard Emulation *Enable Keyboard Wedge Emulation 5155153 415574 Use this with special stand-alone models that are not cabled for an external keyboard. Scan this bar code to enable the Stand-Alone Mode. The scanner will send keyboard “power on” information and configure hardware to simulate a constant keyboard connection.
MetroSelect™ Country/Scan Code Table Selects *USA Keyboard Switzerland Keyboard 416240 416280 Enable USA Keyboard. Enable Swiss Keyboard. Spain Keyboard Italy Keyboard 416250 416240 Enable Spanish Keyboard. Enable Italian Keyboard. Germany Keyboard 416230 Enable German Keyboard. H-2 France Keyboard 416220 Enable French Keyboard.
H-3 MetroSelect™ UK Keyboard Belgium Keyboard 416210 416200 Enable UK Keyboard. Enable Belgium Keyboard. Japanese Keyboard IBM 4700 Financial Keyboard 4162100 416270 Enable Japanese Keyboard. Enable IBM 4700 Financial Keyboard.
MetroSelect™ Keyboard/System Type *AT Keyboard 216215 If using an AT computer, scan the above. (Includes IBM PS/2 and compatible models 50, 55, 60, 80) PS/2 Keyboard XT Keyboard 216205 216225 If using an XT computer, scan the above. Scan the above for PS/2 computer.
H-5 MetroSelect™ Special Keyboard Features Transmit Make Code Only *Transmit Make/Break Code 116311 116301 Do not scan unless instructed by a Metrologic representative. Do not scan unless instructed by a Metrologic representative. Do Not Transmit F0H Break Code *Transmit F0H Break Code 116300 116310 The scanner will not transmit the F0H in the break-code sequence. The scanner will transmit the F0H in the break-code sequence. Transmit Cleanup Bit 116315 Use for certain NEC computers.
MetroSelect™ Enable Alt Mode *Disable Alt Mode 116217 116207 When enabled, the scanner will duplicate this keyboard sequence: Caution: If host software application uses the right Alt key as a “Hot” key. Alt mode must be disabled. Hold down ALT key: Type decimal number that corresponds to the appropriate character. Enable Auto Detect Mode (AT/PS2) *Disable Auto Detect Mode (AT/PS2) 116214 116204 Automatically detects caps lock status. When disabled, the Caps Lock feature is not supported.
H-7 MetroSelect™ Send Numbers as Keypad Data 116316 *Send Numbers as Normal Data 116306 When enabled, all data is sent as if it has been entered on a keypad. Enable Reserved Feature 116410 *Use Extended ASCII To Send Extended Key Codes *Disable Reserved Feature 116400 Use Extended ASCII Characters As Extended ASCII 116303 116313 Use extended ASCII characters to send PC keyboard keys such as F1, F2, etc...See section M for details. Transmit extended ASCII codes via ALT Mode.
MetroSelect™ *Character KBInhibit Message KB Inhibit 116304 116314 InterScan Code Delays *InterScan Code Delay 800 Microseconds 816580 The time specified represents the amount of time between individual 9 bit-scan codes. This parameter may need to be adjusted for operation with certain PC keyboard BIOS. InterScan Code Delay 15 msec 81651500 The time specified represents the amount of time between individual 9 bit-scan codes.
H-9 MetroSelect™ Control Sets In general, standard bar code symbologies will only encode the ASCII character set. Function keys, arrow keys and many other “extended” keys on an IBMcompatible keyboard do not translate to ASCII characters. One method of “bar coding” the extended keys is to substitute the extended key codes when a specific ASCIIcontrol character is found in the bar code stream. The Control Sets are specific translations of the ASCII (HEX) set.
MetroSelect™ Control Set #1 Continued ASCII (HEX) 0AH 0BH 0CH 0DH 0EH 0FH 10H 11H 12H 13H 14H 15H 16H 17H 18H 19H 1AH 1BH 1CH 1DH 1EH 1FH H-10 ASCII Control LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US Extended Key Caps Lock Shift Tab Alt Enter Control Up Arrow F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Home Esc Page UP Page Down Print Screen End
H-11
MetroSelect™ Section I OCIA OCIA I-1 Load OCIA Defaults I-1 DTS/Nixdorf I-1 DTS/Siemens I-1 NCR-S I-1 NCR-F I-1 I
I-1 MetroSelect™ Enable OCIA Mode Load OCIA Defaults 999993 415544 Select this option if communications requires OCIA (Optically Coupled Interface Adapter). This serial interface is clocked by the host.
MetroSelect™ Section J Light Pen Parameters Enable Light Pen Mode J-1 Spaces/Bar High J-1 Transmit as Scanned/Code 39 J-1 Poll Light Pen Source J-2 Light Pen Extra Toggle J-2 10x Narrow Element Border J-2 50x Narrow Element Border J-2 Set Narrow Element Width J-3 J
J-1 MetroSelect™ Enable Light Pen Mode 415524 Select this option if the scanner will be used in place of a light pen. It provides light pen emulation of each bar code scanned. Spaces High *Bars High 116917 116907 Transmit Code 39 *Transmit as Scanned 116916 116906 All bar codes will be decoded then transmitted as code 39 bar codes. All bar codes will be decoded and transmitted in that symbology.
MetroSelect™ Poll Light Pen 116915 Source *Do Not Poll Light 116905 Pen Source 116915 116905 When chosen, the scanner waits for an active source voltage before transmitting data. When chosen, the scanner will not wait for an active source voltage before transmitting data. Enable Light Pen Extra Toggle *Disable Light Pen Extra Toggle 116911 116901 When enabled, the scanner beeps and toggles the light pen data line with an extra data pulse to condition the decoder.
J-3 MetroSelect™ Set Narrow Element Width *1 ms Narrow Element Width 81681630 60 µs Narrow Element Width 8168100 This option allows the transmission of Light/Pen Wand emulation at 1ms Narrow Element width. 100 µs Narrow Element Width 8168160 This transmits at 100 µs Narrow element width. ~Variable Narrow Element Width 916800 Sets the minimum x-dimension in 6 µs increments. Scan this code followed by a 3 digit code byte sequence found in Section M. Refer to MultiCode Method on page iii.
MetroSelect™ Section K IBM 46xx Configuration IBM Port K-1 IBM Reserved Codes K-2 K
K-1 MetroSelect™ Load 46xx IBM Defaults Enable IBM 46xx Communication 415504 999995 Select this option for IBM 46XX SIOC/RS485 communications. Not all scanners support this interface. The correct interface board is required. Load default format settings for the IBM 46xx systems .
MetroSelect™ IBM Reserved Codes IBM Reserved #2 IBM Reserved #1 317200 317210 IBM Reserved #4 IBM Reserved #3 317220 317230 IBM Reserved #5 317240 K-2
K-3
MetroSelect™ Section L MS9500 Voyager™ Activation Range L-1 CodeGate Status L-2 Laser/Scan Modes L-3 Same Symbol Time Outs L-4 ™ L
L-1 MetroSelect™ Activation Range Use these bar codes to select infrared (IR) sensor activation range for sensing when objects are placed in the scan field.
MetroSelect™ CodeGate™ Status Use the following to control button functions.
L-3 MetroSelect™ Laser/Scan Modes *Normal Scan 418304 Laser turns on after the IR senses a bar code. The laser remains on for approximately 3 to 10 seconds. Blinky Scan Continuous Blinky Scan 418324 418334 Laser turns on after the IR senses a bar code. The laser will blink on/off for approximately 60 seconds. The laser blinks continuously. The IR is inactive. Custom (One Shot) Scan 418344 Laser turns on after the IR senses a bar code. The laser will turn off after a good decode.
MetroSelect™ Same Symbol Time Outs No Same Symbol Time Out 1000 msec Same Symbol Time Out 318910 818900 750 msec Same Symbol Time Out *875 msec Same Symbol Time Out 318930 318920 625 msec Same Symbol Time Out 500 msec Same Symbol Time Out 318950 318940 L-4
L-5 MetroSelect™ 375 msec Same Symbol Time Out 318960 Infinite Same Symbol Time Out 118917 250 msec Same Symbol Time Out 318970
MetroSelect™ Section M Code Bytes Code Byte Usage M-1 Code Bytes 0-5 M-2 Code Bytes 6-9 M-3 Reserved Codes M-4 Code Byte/Code Type Table M-5 ASCII Reference Table M-6 Extended Key Code Reference Table M-11 M
M-1 MetroSelect™ Code Byte Usage NOTE! User Configurable Prefixes, Symbol Length and other features that use these Code Bytes for configuration, require that the scanner be in Configuration Mode. Scan the Enter/Exit Configuration Mode bar code before starting the configuration cycle. Single Code Configuration Mode does not work for these multi-code sequences.
MetroSelect™ Code Bytes 0-5 Code Byte 0 Code Byte 1 0 1 Code Byte 2 Code Byte 3 2 3 Code Byte 4 Code Byte 5 4 5 M-2
M-3 MetroSelect™ Code Bytes 6-9 Code Byte 7 Code Byte 6 6 7 Code Byte 8 8 Code Byte 9 9
MetroSelect™ Reserved Codes ~Enable Reserved Code ~Disable Reserved Code 999988 999987 Contact Metrologic for information about this feature.
M-5 MetroSelect™ Code Byte/Code Type Table Code Byte 004 002 003 005 080 081 082 083 084 091 092 093 094 095 096 099 098 097 Code Types UPC-A UPC-E EAN-8 EAN-13 Code 39 Codabar Interleaved 2 of 5 Code 128 Code 93 MSI Plessey Code 11 Airline 2 of 5 (15 digits) Matrix 2 of 5 Telepen UK Plessey TRI-OPTIC Standard 2 of 5 Airline (13 digits)
MetroSelect™ ASCII Reference Table HEX Value 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 Decimal Value/ Code Byte Value 000 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 Control Keyboard EQV Character NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM @ A B C D E F G H I J K L M N O P Q R S T U V W X Y M-6
M-7 MetroSelect™ ASCII Reference Table HEX Value 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 Decimal/ Code Byte Value 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 Character SUB ESC FS GS RS US SP ! “ # $ % & ‘ ( ) * + , .
MetroSelect™ ASCII Reference Table HEX Value 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D Decimal/ Code Byte Value 052 053 054 055 056 057 058 059 060 061 062 063 064 065 066 067 068 069 070 071 072 073 074 075 076 077 Character 4 5 6 7 8 9 : ; < = > ? @ A B C D E F G H I J K L M Control Keyboard EQV less than greater than shift P letter I M-8
M-9 MetroSelect™ ASCII Reference Table HEX Value 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 Decimal/ Code Byte Value 078 079 080 081 082 083 084 085 086 087 088 089 090 091 092 093 094 095 096 097 098 099 100 101 102 103 Character N O P Q R S T U V W X Y Z [ \ ] ^ _ ‘ a b c d e f g Control Keyboard EQV letter O shift K shift L shift M à, shift N ❧, shift O, underscore accent grave
MetroSelect™ ASCII Reference Table HEX Value 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F Decimal/ Code Byte Value Character 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 h i j k l m n o p q r s t u v w x y z { I } ~ DEL Control Keyboard EQV vertical slash alt mode (alt mode) delete, rubout M-10
M-11 MetroSelect™ Extended Key Code Reference Table Key ➝ Insert Delete Home End Page Up Page Down Right Alt Right Ctrl Reserved Reserved Numeric Keypad Enter Numeric Keypad / F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 At Scan Code 75H 72H 74H 6BH 70H 71H 6CH 69H 7DH 7AH 11H 14H 00H 00H 5AH 4AH 05H 06H 04H 0CH 03H 0BH 83H 0AH 01H 09H XT/PS2 Scan Code 48H 50H 4DH 4BH 52H 53H 47H 4FH 49H 51H 38H 1DH 00H 00H 1CH 35H 3BH 3CH 3DH 3EH 3FH 40H 41H 42H 43H 44H Prefix/Suffix Value Hex = Decimal 80H = 128 81H = 129 82H =
MetroSelect™ Extended Key Code Reference Table Key F11 F12 Numeric + Numeric Numeric * Caps Lock Num Lock Left Alt Left Ctrl Left Shift Right Shift Print Screen Tab Shift Tab Enter ESC Left ALT Make Left ALT Break Left CTRL Make Left CTRL Break * Left ALT + 1 character * Left CRTL + 1 character At Scan Code XT/PS2 Scan Code Prefix/Suffix Value Hex = Decimal 78H 07H 79H 7BH 7CH 58H 77H 11H 14H 12H 59H 57H 58H 4EH 4AH 37H 3AH 45H 38H 1DH 2AH 36H 9AH = 154 9BH = 155 9CH = 156 9DH = 157 9EH = 158 9FH = 15
M-13
MetroSelect™ Section N Miscellaneous Features Custom Defaults N-1 Serial Program Mode N-3 N
N-1 MetroSelect™ Custom Defaults Metrologic manufatures several scanners for OEM applications. These scanners may use a different set of defaults than Metrologic factory defaults. Scanning the bar code will reset the default table to Metrologic defaults. Enable Factory Defaults 846600 Scan this code followed by “Recall Defaults” code to enable and load Metrologic Factory Defaults.
MetroSelect™ Ruby Verifone Defaults RCH 84661280 84660010 Scan this code followed by “Recall Defaults” code to enable and load Ruby Verifone Defaults. Scan this code followed by “Recall Defaults” code to enable and load RCH Defaults. Sanyo Gilbarco 84660020 84660030 Scan this code followed by “Recall Defaults” code to enable and load Sanyo Defaults. Scan this code followed by “Recall Defaults” code to enable and load Gilbarco Defaults.
N-3 MetroSelect™ Serial Program Mode For Serial Program Mode, all commands must be framed by an STX (02 Hex) and ETX (03 Hex). To recall defaults: 1) Transmit 999999 through the Serial Port. This will put the scanner in serial program mode. Scanning will be suspended and the scanner will respond with an ACK (06 Hex). 2) Transmit 999998 through the Serial Port. This is the Recall Defaults bar code in the MetroSelect guide. The scanner will respond with an ACK (06 Hex).