User`s guide

174
CipherLab BASIC Compiler
User's Guide
RSS14 Expanded
Transmit Code ID
If this parameter is enabled, the default Code ID will be included in the
data being transmitted.
Scanner Parameters
The user can define the scanner parameters for reader ports 1 and 2.
Note: The settings for reader port 2 on the 7xx series data terminals will be ignored
because they support only one reader port.
Scan Mode
Auto Off Mode
This is the default scan mode.
The reader will start scanning once the scan trigger is pressed. The
scanning goes on until one of the following events happens.
a barcode is read
time out (preset scanning period expires)
Auto Power Off Mode
The reader will start scanning once the scan trigger is pressed. The
scanning goes on until one of the following events happens.
time out (preset scanning period expires)
Unlike the Auto Off mode, the reader will continue scanning and the
scanning time-out period is re-counted whenever there is a successful
read.
Continuous Mode
The reader is always scanning but will decode the same barcode just
once. To read the same barcode multiple times, the barcode must be taken
away from the scanning line and then replaced.
Repeat Mode
The reader is always scanning just like in the Continuous Mode. But in
this mode the scan trigger acts like a “re-transmit button”.
This scan mode is most useful when the same barcode is to be read many
times. If it is triggered within 1 second after a good read, the same data
will be re-transmitted without actually reading the barcode.
Such re-transmission can be triggered as many times as the user desires,
as long as the time interval between each triggering does not exceed 1
second.