Copyright © 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.
TABLE OF CONTENTS Introduction How does the MX009 USB Cable Operate?......................................................1 What is the difference between USB Keyboard Emulation and USB Serial Emulation? ......................................................................................1 How is the MX009 Configured for USB Keyboard Emulation?..........................2 How is the MX009 Configured for USB Serial Emulation? ................................3 MX009 USB Cable Options .........................
INTRODUCTION Metrologic’s MX009 USB Cable is a device that converts serial RS232 formatted data to either USB Keyboard or USB Serial communication protocol. The MX009 can be used with all Metrologic products equipped with an RS232 interface, as well as all versions of Metrologic PowerLink compatible scanners. All versions of Metrologic’s PowerLink compatible scanners are equipped with RS232 transmit and receive communication lines.
INTRODUCTION • HOW IS THE MX009 CONFIGURED FOR USB KEYBOARD EMULATION? This guide contains the configuration bar codes necessary to ensure that the scanner communicates properly with the MX009. The scanner communicates using RS232 protocol.
INTRODUCTION (CONT.) • HOW IS THE MX009 CONFIGURED FOR USB SERIAL EMULATION? This guide contains the configuration bar codes necessary to ensure that the scanner communicates properly with the MX009. The scanner communicates using RS232 protocol.
MX009 USB CABLE OPTIONS MX009 USB KEYBOARD E MULATION C ABLES PART NUMBER STRAIGHT COILED 10-pin RJ45 Male All versions of the: MS6220, MS6520, IS6520, MS7100, MS7220, MS9500, MS3580 and IS3580 Type A 10-pin RJ45 Female MS6720-14, IS4225-14, IS4225-81 MS951-14, MS961-14, IS4220-14, IS4220-81 Type A 25-pin D-Sub Female MS860-1, MS860-2, MS860-11, MS860-17 MS700-1, MS700-2, MS700-11, MS700-17 Locking Type A 10-pin RJ45 Male All versions of the: MS6220, MS6520, IS6520, MS7100, MS7220, MS9500, MS
MX009 PART NUMBER DESIGNATION AND ACCESSORIES PARTS AND ACCESSORIES Part No. Description MX009 USB Converter Cable MX009-2xx7x USB Keyboard Emulation Cable MX009-2xx8x USB Serial Emulation Cable PART NUMBER DESIGNATION † Application Dependent AC to DC Power Transformer (Optional) 00-02574X MX009 USB Converter Cable Configuration Guide † Available for download on Metrologic's website, www.metrologic.com.
CABLE INSTALLATION Make sure the AC input requirements of the power supply match the AC outlet. The outlet should be near the equipment and easily accessible.
LABELS Each MX009 has CE, UL and caution information embedded in the back of the case. The following is an example of embedded information. Figure 1. Each MX009 will also have a flag tag attached to the cable with the date of manufacture, model number, and serial number. Figure 2. ** Illustrations shown are not actual size.
CONFIGURING FOR USB KEYBOARD EMULATION (MX009-2XX7X) PowerLink Compatible Scanners These Metrologic Scanners, used with the MX009 Cable must be reconfigured using the following bar codes before the MX009 can communicate properly with a host system.
CONFIGURING FOR USB KEYBOARD EMULATION (MX009-2XX7X) 4. Scan the appropriate bar code below to set USB Keyboard Emulation to the country keyboard required (defaults to USA). USA ³ 4 1 6 2 6 0 SWITZERLAND ³ 4 1 6 2 8 0 SPAIN ³ 4 1 6 2 5 0 ITALY ³ 4 1 6 2 4 0 GERMANY ³ 4 1 6 2 3 0 FRANCE ³ 4 1 6 2 2 0 Continued on next page.
CONFIGURING FOR USB KEYBOARD EMULATION (MX009-2XX7X) UNITED KINGDOM ³ 4 1 6 2 1 0 BELGIUM ³ 4 1 6 2 0 0 JAPANESE ³ 4 1 6 2 1 0 0 IBM 4700 FINANCIAL KEYBOARD ³ 4 1 6 2 7 0 SWEDEN/FINLAND ³ 4 1 6 2 9 0 5.
CONFIGURING FOR USB KEYBOARD EMULATION (MX009-2XX7X) MS6720, MS860, AND TECH SERIES These Metrologic Scanners, used with the MX009 Cable must be reconfigured using the following bar codes before the MX009 can communicate properly with a host system. • • MS6720 Note: • MS860 Tech Series Configuration for USB Keyboard Emulation must be completed before enabling/disabling any additional features documented in the configuration guide provided with the scanner.
CONFIGURING FOR USB KEYBOARD EMULATION (MX009-2XX7X) 4. ENABLE XON/OFF HANDSHAKING 0 12345 11714 5 5. ENABLE ACK/NAK 0 12345 11713 8 6. CONFIGURABLE PREFIX #1 0 12345 92000 4 7. CONTROL V PREFIX 0 12345 00022 5 8. CONFIGURABLE PREFIX #2 0 Continued on next page.
CONFIGURING FOR USB KEYBOARD EMULATION (MX009-2XX7X) 9. Scan one of the following bar codes to set Keyboard Emulation. BELGIUM 0 12345 00065 2 UNITED KINGDOM 0 12345 00066 9 FRENCH 0 12345 00067 6 GERMAN 0 12345 00068 3 ITALIAN 0 12345 00069 0 Continued on next page.
CONFIGURING FOR USB KEYBOARD EMULATION (MX009-2XX7X) SPANISH 0 12345 00070 6 UNITED STATES 0 12345 00071 3 SWISS 0 12345 00073 7 SWEDISH/FINNISH 0 12345 00074 4 JAPANESE 0 Continued on next page.
CONFIGURING FOR USB KEYBOARD EMULATION (MX009-2XX7X) RESERVED 0 12345 00076 8 10.
CONFIGURING FOR USB SERIAL EMULATION (MX009-2XX8X) PowerLink Compatible Scanners These Metrologic scanners must be reconfigured using the following bar codes before the MX009 can communicate properly with the host system.
CONFIGURING FOR USB SERIAL EMULATION (MX009-2XX8X) MS6720, MS860, AND TECH SERIES These Metrologic scanners must be reconfigured using the following bar codes before the MX009 can communicate properly with a host system. • MS6720 Note: • • MS860 Tech Series Configuration for USB Serial Emulation must be completed before enabling/disabling any additional features documented in the configuration guide provided with the scanner.
CONFIGURING FOR USB SERIAL EMULATION (MX009-2XX8X) 4. ENABLE XON/XOFF HANDSHAKING 0 12345 11714 5 5. ENABLE ACK/NAK 0 6.
TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 22. Test Bar Code Scanning the following bar code will transmit the encoded characters followed by the software number of the MX009. M t SYMPTOMS L g - m x 0 0 9 POSSIBLE CAUSE(S) SOLUTION No Power is being supplied to the scanner Make sure the cable is plugged into the scanner.
SPECIFICATIONS MX009 USB CONVERTER CABLE SPECIFICATIONS MECHANICAL Dimensions: Weight: 80.4 mm (3.2”) L x 32.4 mm (1.3”) W x 18.7 mm (0.7”) H 160 g (0.35 lb) 10-pin modular RJ45 Male to USB Termination: 10-pin modular RJ45 Female to USB. 25-pin Female D-Sub to USB Cable: Straight or Coiled ELECTRICAL Input Voltage: EMC: 5.0 VDC ± 0.
CABLE INFORMATION Scanner Connector End 1 USB Connector End 4 4 1 10 Type A 10-Pin RJ45 Male Pin 1 2 3 4 5 6 7 8 9 10 Function Ground TXD RXD RTS CTS DTR/LP Reserved LP Data +5 VDC From Transformer SHD/GND MX009-2MA7x and MX009-2MA8x 10 Pin 1 2 3 4 MX009-2MB7x and MX009-2MB8x USB Connector End 4 4 10-Pin RJ45 Female Type A Function Ground TXD RXD RTS CTS DTR/LP SRC Reserved LP Data +5 VDC From Transformer SHD/GND MX009-2FA7x and MX009-2FA8x or 1 Locking Type A MX009-2FB7x and MX009-2FB8
LIMITED WARRANTY The MX009 USB converter cables are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility and at its Suzhou, China facility. The MX009 USB converter cables have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MX009 USB converter cables are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S.
NOTICES TESTED TO COMPLY WITH FCC STANDARDS FOR HOME OR OFFICE USE Notice This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.
NOTICES DECLARATION OF CONFORMITY According to 47 CFR, Part 2 and 15 for Class B Personal Computers and Peripherals; and/or CPU Boards and Power Supplies used with Class B Personal Computers: We: Metrologic Instruments, Inc. Located at: 90 Coles Road Blackwood, NJ 08012 Telephone: 856-228-8100 Declare under sole responsibility that the product identified herein, complies with 47 CFR Part 2 and 15 of the FCC rules as a Class B digital device.
ADDITIONAL BAR CODES Some Metrologic scanners require alternate configuration steps than the steps found on pages 8 - 18. If your scanner was manufactured before May 2002 or does not accept the standard configuration sequences, you may need to use one of the alternate configuration methods listed on the following pages. Contact a Metrologic customer service representative to help determine if your scanner requires one of these methods.
ADDITIONAL BAR CODES 7. *Enable LF Suffix ³ 1 1 6 6 1 2 8. Scan the appropriate bar code below to set USB Keyboard Emulation to the country keyboard required.
ADDITIONAL BAR CODES UNITED STATES ³ 8 0 3 6 0 7 1 0 RESERVED ³ 8 0 3 6 0 7 2 0 SWISS ³ 8 0 3 6 0 7 3 0 SWEDISH/FINNISH ³ 8 0 3 6 0 7 4 0 JAPANESE ³ 8 0 3 6 0 7 5 0 RESERVED ³ 8 0 3 6 0 7 6 0 9.
ADDITIONAL BAR CODES Alternate Configuration for USB Serial Emulation (MX009-2xx8x) PowerLink Compatible Scanners 1. ENTER/EXIT CONFIGURATION MODE ³ 9 9 9 9 9 9 2. RECALL DEFAULTS ³ 9 9 9 9 9 8 3. ENABLE RS-232 MODE ³ 4 1 5 5 5 4 4. ENABLE XON/XOFF HANDSHAKING ³ 1 1 5 9 1 4 5. ENABLE ACK/NAK ³ 1 1 5 9 1 3 Continued on next page.
ADDITIONAL BAR CODES 6. *ENABLE LF SUFFIX ³ 1 1 6 6 1 2 7.
CONTACT INFORMATION AND OFFICE LOCATIONS CORPORATE HEADQUARTERS NORTH AMERICA USA, New Jersey Metrologic Instruments, Inc. Tel: 1-800-ID-METRO Fax: 856-228-6673 Email: info@metrologic.com SOUTH AMERICA AND CENTRAL AMERICA Brazil São Paulo Metrologic do Brasil Ltda. Tel: 55-11-5182-8226 Fax: 55-11-5182-8315 Email: info@br.metrologic.com EUROPEAN, MIDDLE EAST & AFRICAN HEADQUARTERS Germany, Munich Metrologic Instruments GmbH Tel: 49-89-89019-0 Fax: 49-89-89019-200 Email: info@europe.metrologic.
June 2005 Printed in the USA 00 - 02574D