Operating instructions
The “Dynamic Weighing” application
134
At the factory, data output is set to a standard format:
Example (21.45 g):
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
d w N 2 1 . 4 5 g C
R
L
F
The identifier “dw” indicates that the data record relates to the calculated weight value
of a dynamic weighing, “N” stands for a net weight value. The weight value is followed by
the end-of-line character that was defined for the host (section 3.7).
If you want to change the output format, activate “Customise” and then touch the “De-
fine” key.
This menu contains settings for the following data fields:
– DW identifier
– Net weight symbol
– Weight value
– Weight unit
In the output unit, these fields are always separated by a space character. The complete
data record is terminated with the end-of-line characters that were defined for the host
(section 3.7).
The settings for the individual fields are explained below.
DW identifier
In the standard output format, the weight values are always preceded by the identifier
“dw” (“dynamic weighing”), which indicates that the weighing result is calculated from
several individual measurements. In this menu, you can activate and deactivate (“Off”)
this function, select the symbol to be used (“*” or “dw”), and also specify the field length
(1 – 10 characters). The identifier is aligned right-justified in the field.
Factory setting: Identifier deactivated (“Off”).
Field length 2 characters.