Weighing Terminal
Resolution (approvable)
Dimensions (H×W×D)
Display
Keypad
Housing
Protection
Interfaces
Applications
Special features and
functions
Accessories
Attachable platforms
Hazardous area
approval
100 000d / (approvable): Analog – 10 000e OIML,
10 000d NTEP; IDNet – 100 000d OIML, NTEP
Panel-Mount: 265×160×91.8mm;
Desk/Wall/Column-Mount (Harsh): 265×160×170.3mm
Vacuum florescent, 21mm weight display,
graphical 128×64 dot, SmartTrac™ display modes
25-key tactile-feel keyboard with numeric keypad
Harsh – Stainless steel; Panel – Stainless steel faceplate,
Aluminum chassis
Harsh: IP69k
Panel:Type 4x/12 (IP65)
Com 1: RS-232/RS-422/RS-485, Optional Ethernet
10/100-baseT, plus 2 additional serial ports
Filling, Vehicle, Dynamic/In-Motion,
Freely programmable via TaskExpert™
Basic Functionality incl. Step Calibration, CalFREE™
Calibration methodology; SmartTrac™ Display Modes;
MinWeigh
®
; TraxDSP™ Digital Filtering, TraxEMT™
Maintenance Diagnostics, InSite
®
Configuration Tool
Optional communications interfaces: PLC (one option only):
Allen Bradley
®
Remote I/O, EtherNet/IP™, Profibus
®
DP;
DeviceNet™, Analog Output and Modbus
®
/TCP;
Optional I/O Interfaces: Local: (1) 4 inputs/6 outputs,
Max. 12 inputs/18 outputs. Use remote ARM100 modules,
4 inputs/6 outputs each.
1: analog, IDNet
Harsh:
ATEX: II 3 G EEx [nL] IIB T4 (Gas)
FM: Class I, Div 2; Groups A–D, Class 1 Zone 2, Group IIC, T4
Panel:
ATEX: II 3 G EEx nL [nL] IIB T4
II 3 D T85°C IP6x
FM: Class I Groups A–D , Div 2; Class II Groups F, G, Div 2;
Class III ; Div 2; Class 1 Zone 2 Group IIC, T4
Solutions for the
harshest Environments
To withstand the environments of
the pharmaceutical and chemical
industries, the IND560 is assured
Type 4/12 (Panel) and IP69k
(harsh) protection categories.
The needs of the food and beverage
industries are also met. The unit’s
304 stainless steel construction
and polished, sanitary finish resist
aggressive cleaning agents, high
pressure and temperature cleaning
requirements dictated by EHEDG
and NSF guidelines.
Maintain Uptime and
ensure System Quality
• TraxEMT™, the Embedded
Maintenance Technician,
sets the IND560 apart. Monitor
and analyse system perfor-
mance, enabling action before
a failure occurs
• Advanced calibration options
allow for the most cost effective
operation. Use the automated
5-Point or Step Calibration rou-
tines for the highest accuracy.
The exclusive CalFREE tecnology
is available to get up and
running without test weights
• The InSite
®
Configuration
Tool provides connected or
offline access to the IND560
terminal for efficient and re-
peatable setup. Quickly and
accurately upload or download
system parameters via a serial
or Ethernet connection
• MinWeigh
®
functionality helps
insure the weighing of your
critical ingredients are always
within acceptable limits by
displaying a warning when the
weight is below the minimum
weight threshold.