Operating instructions

Dispensing functions
10 Operating instructions 22012836B 09/08
IND690-Fill
1.6.3 Dispensing with a supply vessel on the weighing platform
During dispensing the filling container is dispensed from a supply vessel on the
weighing platform.
1. Enter dispensing parameters, see section 1.5.
The display shows READY FOR DISPENSING.
2. Place filled supply vessel on the weighing platform.
3. Press START key.
The display shows the following: weight value with negative sign, dispensing
status and DeltaTrac.
When the dispensing process is completed, the display indicates whether the
weight value lies within the tolerance limits (DISPENSING OKAY) or outside
(OVERFILLED, UNDERFILLED).
The dispensing result is printed.
4. Acknowledge dispensing process.
If ACKNOWLEDGEMENT ON is set in master mode, READY FOR DISPENSING is
shown in the display. With ACKNOWLEDGEMENT OFF, the next dispensing
process is started automatically.
1.7 Interrupting dispensing process
Same container 1. Press STOP key.
The dispensing process is interrupted.
2. To continue the dispensing process, press START key.
New container 1. Press STOP key twice.
The dispensing process is cancelled.
2. Place a new container on the weighing platform.
3. If TOTALIZING ON is set in the master mode, the sum can be displayed with the
SUM key.
4. To continue the dispensing process, press START key.
1.8 Cancelling or ending the dispensing process
By pressing key on
weighing terminal
Press STOP key twice.
The dispensing process is cancelled or ended when the dispensing process is
completed.
By external signal Cancel dispensing process with a pulse at input IN 7 of first 8-690 relay box. The
IND690-Fill is then in the READY FOR DISPENSING (010) state.
Note
If TOTALIZING ON, CORRECT DISPENSINGS is set in the master mode, cancelled
dispensing processes can be added to the sum by pressing the SUM key when
CONTINUE WITH START is displayed.