Operating instructions
Application blocks
32 Operating instructions 22012836B 09/08
IND690-Fill
3 Application blocks
In the following description, the application blocks are shown in the syntax for the
MMR command set. When used with the SICS command set, please observe the
SICS conventions, see Operating instructions for IND690-Base weighing terminal.
No. Content Format
301 Pac version Response: {A[B|_|IND690-Fill_Vx.xx_}
302 Program number Response: {A[B|_|IP64-0-0xxx_}
305 Keypad entry or read-
in barcode
Response: {A[B|_|Entry}
Write: {A[W|3[0[5|_|$|$|Entry}
Comment: Entry = Text_20, number or weight value
306 Electronic finger Response: {A[B|_|K[e[y[s[_[_[_[_[1[-[1[2[,[2[3[-[4[7}
Write: Trigger keys for the electronic finger
{A[W|3[0[6|_|$|$|Number (1 … 12; integral)}
Each number is assigned a key:
1: N key
2: SUM key
3: CODE A key
4: MAN key
5: LIMIT key
6: CODE B key
7: STOP key
8: CODE C key
9: START key
10: CODE D key
11: CLEAR key
12: ENTER key
Correct triggering of the key is confirmed with a beep tone.
Recall target memory
{A[W|3[0[6|_|$|$|Number (1 … 47; integral)}
Number: 22: Display current dispensing parameters
23_001 ... 23_999 or 23 … 47:
Call up target memory 1 … 999 or 1 ... 25
310 Item counter Response: {A[B|_|Number_4}
311 Start value
item counter
Response: {A[B|_|Number_4}
Write: {A[W|3[1[1|_|Number_4}
312 Stop value
item counter
Response: {A[B|_|Number_4}
Write: {A[W|3[1[2|_|Number_4}
313 Sum net weight Response: {A[B|_|Weight value|_|Unit}
314 Sum gross weight Response: {A[B|_|Weight value|_|Unit}