IND690-Fill
6.2.3 Above-level application
OUT1 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 IN4
Fine feed Coarse
feed
Poor Accept-
able
End of
dispensi
ng
Start/
output 7
Ready Acknow-
ledge
Target value entered
Pulse output started, coarse feed switched on
Limit 1 reached: coarse feed switched off, fine
feed switched on
Limit 2 reached: fine feed switched off, wait for
stabilization of weighing platform
Stabilization of weighing platform, dispensing
result evaluated and printed out
Movement > 30 digit or acknowledgement
Ready for next dispensing