Operating instructions

Dispensing functions
Operating instructions 22012836B 09/08 7
IND690-Fill
1.5 Entering dispensing parameters
Entering numerically 1. Press LIMIT key.
2. Enter target weight and confirm with ENTER.
3. Specify limits: enter ENTER LIMIT 1 and LIMIT 2 and confirm with ENTER.
To automatically determine the limits, press ENTER without making an entry.
4. Specify tolerance: enter TOL and confirm with ENTER.
5. If tare checking is to be used, specify tare values TMIN and TMAX and confirm
with ENTER.
Notes
The weight unit for entering the limits can be selected with the cursor keys < or >.
The entry can be corrected one character at a time with the CLEAR key.
If LEARN MODE OFF is set in the mastermode, Limit 1 and Limit 2 must be
specified, and if the 3rd switch-off point is also activated (see section
2.2.5),
Limit 0 as well.
If PASSWORD BLOCK ON is set in the master mode, a personal code must be
entered after pressing the LIMIT key.
If ANALOG OUTPUT ON is set in the master mode, the throughput preflow (with
additionally activated 3rd shutoff point), throughput coarse feed and throughput
fine feed must be specified.
Press the LIMIT key in order to display or correct dispensing parameters in the
READY FOR DISPENSING state. The target weight cannot be entered in this case.
Copying constants 1. Enter number of target memory: 1 … 999.
2. Press LIMIT key.
Note
If PASSWORD BLOCK ON is set in the master mode, a personal code must be entered
after pressing the LIMIT key.
1.6 Dispensing
The dispensing type is dependent on the application set in the master mode:
ABOVE LEVEL: Dispensing above the filling level (without filling lance)
BELOW LEVEL Dispensing lance below the dispensing level
The filling process is not started unless the dispensing lance is recognised in the
right position, meaning that the input signal NOZZLE DOWN has to be active.
BELOW BUNGHOLE Dispensing lance below the bung hole
The filling process is not started unless the dispensing lance is recognised in the
right position, meaning that the input signal NOZZLE MIDDLE has to be active.