Specifications

METTLER TOLEDO PS Shipping Scale Technical/Operators Manual
METTLER TOLEDO PS Shipping Scale Technical/Operators ManualMETTLER TOLEDO PS Shipping Scale Technical/Operators Manual
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual
(03/01) 3-
(03/01) 3-(03/01) 3-
(03/01) 3-6
66
6
2.
2.2.
2.
Press ZERO to display the desired bit selection. Options include:
Seven (7)
Eight (8)
3.
3.3.
3.
Press UNITS to accept the displayed option. The PS continues to the
Parity program block.
Parity Program Block
Parity Program BlockParity Program Block
Parity Program Block
The Parity program block lets you select the parity option for data
transmission. Parity is an error checking mechanism. To configure the
program block:
1.
1.1.
1.
Press UNITS to display the PAr prompt, then press ZERO.
2.
2.2.
2.
Press ZERO to display the desired parity option. Options include:
Space Even
Mark None
Odd
3.
3.3.
3.
Press UNITS to accept the parity option. The PS continues to the Stop
program block.
Note: options will depend on the ASCII bits selection.
Stop Program Block
Stop Program BlockStop Program Block
Stop Program Block
The Stop program block lets you select the number of stop bits to be
transmitted for each ASCII character. Most METTLER TOLEDO products
will work with either 1 or 2 stop bits.
To configure the program block:
1.
1.1.
1.
Press UNITS to display the StoP prompt, then press ZERO.
2.
2.2.
2.
Press ZERO to display 1 or 2 stop bits, then press UNITS to accept the
displayed selection. The PS continues to the Protocol program block.
Protocol Program Block
Protocol Program BlockProtocol Program Block
Protocol Program Block
The Protocol program block lets you select a pre-configured set of scale
commands. Protocols are configured in the factory according to your ordering
information. This section gives instructions on how to select a protocol only.
To select a protocol:
1.
1.1.
1.
Press UNITS to display the Proto prompt, then press ZERO.
2.
2.2.
2.
Press ZERO to display the desired protocol. Options include:
Toledo (MT command set) Proto 4 (UPS command set)
Proto 1 (Fed Ex command set) Proto 5 (Purolator command set)
Toledo protocol contained in the
PS is identical to the Toledo
protocol within the industrial builds
of the 8213. The PS replaces the
industrial versions of the 8213.