Specifications
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual
METTLER TOLEDO PS Shipping Scale Technical/Operators ManualMETTLER TOLEDO PS Shipping Scale Technical/Operators Manual
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual
(03/01) 3-
(03/01) 3-(03/01) 3-
(03/01) 3-8
88
8
End Program Block
End Program BlockEnd Program Block
End Program Block
The End program block lets you save the configuration and exit setup mode.
This program block does not have parameters to configure.
To use the End program block:
1.
1.1.
1.
Press UNITS to display the End prompt.
2.
2.2.
2.
Press ZERO to display the desired exit option. Exit options include:
• Default—Reset all program block parameters to standard MT values,
then exit setup mode.
• Abort—Exit setup mode but do not save any changes made in this
session.
• Save—Do not exit setup mode at this time. PS returns to the first
program block.
• Def x—Company specific.
If you are using software from one of the following carriers your PS scale
can be completely configured for use by selecting one of the options
below (not available on PS6L):
Carrier End
prompt selection
• RPS Default
• DHL Default
• Fed Ex Def 1
• UPS Def 4
• Purolator Def 5
• Airborne Def 6
Choosing a default, rather the selecting SAVE, will automatically set the
following program blocks:
• Zero Cursor • PARITY
• Power-up Units • STOP BITS
• Units Switching • Sleep Mode
• Filter • Protocol
• BAUD • Display Mode
• ASCII BIT String
The PS6L only has the Default option. This is the standard MT
communications parameters and command set.
If your carrier is not listed try the default option, otherwise contact your
carrier.
3.
3.3.
3.
Press UNITS to carry out the displayed option.