METTLER TOLEDO Operation
Type: Selection between EAN8 and EAN13
* • Asterisk key
* confirm entries, enter
number of next bar code you
wish to create.
- NonSalesMode- BARCODE-
Identific. Definition Digits Position EAN-13 Remark
0...9
Digits 12 1 - 12
A
Article 12 1 - 12 when label printout
Department 4 1 - 6 when strip printout
B
Amount 8 8 - 12
C
Check sum 1 7+ 8, 13 obligation for last position
D
Date 6 not supported so far
E
Calendar day 3 1 12
N
Receipt number 5 1 - 6
P
PLU 6 1 - 6
Q
Quantity 8 - 12 Piece PLU
Weight cell 5 8 - 12 Weight PLU
R
Weight with 3 decimal digits 5 8 - 12 Weight PLU
S
Weight with 2 decimal digits 5 8 - 12 Weight PLU
T
Weight with 1 decimal digit 5 8 - 12 Weight PLU
W
Article group 4 1 - 6
U
Department ID 12 1 - 12
Remarks:
Each identification is only permissible as a coherent block. This block may only exist once.
Exception: Digits may be placed everywhere, as well as several blocks.
EAN-13: Check sum has to be at position 13, additionally also possible at position 7 or 8.
EAN-8: Check sum has to be at position 8 (and only there)
PLU is our internal PLU Number, article is SAN (Standard Article Number, partially worldwide unique)
Amount and weight are always printed without a comma, the amount with decimal digits, and the weight in
grams.
Q ist printed in the same format as deliverd by the cell. R,S,T are re-formatet to fix decimal digits.
Identification T may have variable meanings.