User guide

10
CHAPTER 1
NETWORK SPECIFICATIONS
Maximum Loudspeaker Nodes
Twisted-pair system with a maximum of 62 nodes
(maximum of 50 recommended); up to 115 nodes with
a network repeater
Ethernet network with i.LON 10 with up to 50 nodes
per network segment
Twisted-Pair Cable Type
20 AWG (Belden 8205 or equivalent) twisted pair,
stranded, unshielded
Ethernet Cable Type
Category 5 or higher. Straight-through (patch) cable
if using a hub or a switch. Use a crossover cable if
wiring the computer's Ethernet port directly to an
i.LON 10.
Connector Types
Twisted pair: Weidmuller 2 conductor locking
connector
Ethernet: 10BASE-T, type RJ-45
Portable: XLR and EN3
Maximum Network length
Maximum network length without installation of
repeater(s):
- Free Topology: 20 AWG, 18 AWG or 16 AWG
cable, one 52.3-ohm type terminator: 500 m (1,640
ft)
- Ethernet: 10BASE-T network limitations plus
Standard twisted pair limitations
Termination
Free Topology: One 52.3-ohm type terminator at any
point
Bus Topology: Two 52.3-ohm type terminators (one on
either end)
Connector Type
2-wire plug with recommended snap-on lock
Network Platform
Differential Manchester Encoding; Polarity Insensitive,
Free Topology
Transceiver
EMI, complies with FCC Part 15, Class A; UL
recognized; VDE: EMI compliant
Data Rate
200 ms data transfer rate with 20 loudspeakers