SETTING GAS MIXTURE CONTROLS ON TORCH HANDLE
Step One - Turn off both control knobs (fuel and oxygen) on the torch handle to the full
closed position. The propane control is identified in red. The oxygen control
is identified in green.
Step Two - Open the oxygen control knob one and one-half (1 1/2) turns from the full
closed position. The control knob has a notch to assist in determining
amount of turns.
Step Three - Open the propane control knob by turning one-eighth (1/8) to one-quarter
(1/4) turn from the full closed position. The control knob has a notch to assist
in determining amount of turns.
Notice:
The gas mixture settings on the torch handle will remain the same for
all target species. Occasionally re-check settings for accidental
movement between applications.
The correct setting for the gas mixtures and regulator settings are also
shown on the information decal affixed to the top of the canister of the
Rodenator.
The control knobs are notched to show how far they have been opened
from the full closed position.
If you are using the Rodenator Pro in altitudes above 5000 feet above
sea level, please contact customer support for additional information
on high altitude settings.
Refer to page 27 for additional information on setting adjustments.