Pulsar™ ESV 8+Rack / 11+Rack 14+Rack / 22+Rack user manual – ! … 2 … 1… – + + … … … … % % www.mgeups.
Dear Customer, Thank you for your purchase of the Pulsar UPS. It has been designed for many years of trouble-free operation. Please review this manual which has been prepared to provide you with information concerning the proper installation and operation of your Pulsar ESV 8+Rack / 11+Rack /14+Rack /22+Rack. Please feel free to call us at our toll-free number on the last page should you require assistance.
safety rules ■ this equipment can be operated by any individual, with ■ do not place Pulsar in direct sunlight or close to heat- released electrolyte is harmful to the skin and eyes; no previous training; emitting sources; ■ a battery can present a risk of electric shock and high ■ the UPS contains voltages which are potentially ■ the utility power outlet shall be near the equipment and hazardous.
Pulsar ESV 8+Rack/11+Rack/14+Rack/22+Rack : 86-153523-00 MGE UPS SYSTEMS
general contents discover Pulsar .......................................................................................................................................... 6 illustrations and features key diagram introduction / getting started/ operation MGE UPS SYSTEMS ............................................................................................................
front view of ESV 8+Rack/11+Rack/14+Rack/22+Rack – ! … 2 … 1… – + rear view of ESV11+Rack/14+Rack + … … … … 1a % 1b 2 % 12 1c 7 15 7a 6 1d 3 TEM 1g 1 1f 2 1e MG PS EU SYS c.
rear view of ESV8+Rack 15 10 5V /12 0A T1 . c S, In Vac IN TEM PS EU MG 7a The indispensable companion sofware for your UPS solution-pac 12 SYS L'indispensable complément logiciel de votre onduleur 9 1 UT O Vac 5 13 A 2 I x ma 6.
key to diagrams page 6 to 8 rear view of ESV22+Rack 1a yellow indicator light flashing quickly only: battery fault, 1b yellow indicator light flashing quickly only: device fault, 1c yellow indicator light flashing quickly only: overload, 1d yellow indicator light flashing quickly only: operating on "booster" or "fader" mode, 12 1e yellow indicator light flashing quickly only: plug 2 not powered, 1f yellow indicator light flashing quickly only: plug 1 not powered, 1g green indicator light on continuously
key to diagrams page 6 to 8 2 "function" button: switches off audio warning device or measures load charge percentage (with utility power), 7 3 "ON/OFF" switch, 4 utility input receptacle, 5 utility power connection (use computer cord only for ESV 8+Rack), 6 15A, circuit protector for Pulsar ESV 11+Rack output receptacles for connection of computer equipments to Pulsar ESV+Rack (2 for ESV 8+) with output switchable receptacles 7a and 7b by Solution-Pac, 8 power cords for connection of computer
software supplied with Pulsar ESV+Rack Solution-PacTM for networks and multi-server systems To meet the different operating environments of your UPS, Pulsar ESV+Rack includes 2 MGE UPS SYSTEMS software programs: ■ ESV-Driver software for Windows; ■ Network based Solution-Pac™ power management software.
contents introduction ......................................................................................................................12 benefits ......................................................................................................................................12 options........................................................................................................................................12 getting started .............................................................
introduction of Pulsar UPS benefits Network servers and data are very sensitive to electrical disturbances of all types including outages, brownout, voltage sags, interference, etc. The origins of disturbances also vary, ranging from atmospheric phenomena such as lightning or frost, to near-by devices generating interference such as elevators, copiers and machine-tools, not to mention human errors such as the accidental pulling out of power cords or tripping of circuit breakers.
getting started installation ■ observe the safety rules indicated at the beginning of this document. preliminary checks ■ check that button 3 " " on the front is not pushed in; ■ check that rating shown on identification plate 10 corresponds to the input voltage specification and power requirement of the load. Connect the UPS input cord 5 to a nearby power outlet. For the ESV8+Rack, the input cord is not attached to the UPS.
communication The communication port 9 , at the rear of Pulsar, delivers information in the form of an RS232 serial link supported by the communication protocol exclusive to MGE UPS SYSTEMS. The Solution-Pac programs use the data made available by this protocol. 5 4 3 9 9 8 7 6 I V 1 2 3 5 - ground TD RD common 0V 5 4 9 With the ESV Driver software program you can set up Pulsar ESV+Rack to suit your user conditions (ESV Tuner).
operation starting up with utility power present press button 3 (>1 sec.) press button "on/off" : automatic sequence: 0s indicator lights and audio warning device test battery test battery test normal operation 4s 6s 9s 12s indicating the recharge percentage of the battery (100, 75, 50, 25%): here > at 50% 1 s beep Your protected devices are not powered MGE UPS SYSTEMS several beeps your protected devices are not powered 1 beep every second your main devices are supported by the battery.
starting up without utility power press button 3 (>1 sec.) automatic sequence: 0s indicator lights and audio warning device test battery test battery test normal operation with battery autonomy 4s 6s 9s 12s indicating the remaining autonomy percentage (<100, 75, 50, 25%): here < 50% 1 s beep Your protected devices are not powered 16 several beeps your protected devices are not powered 3s beep your main devices are supported by the battery.
normal operation input voltage variation range without utility power output voltage variation range (*) 1 beep every 10 s 138 Volts max "fader" mode in operation indicating the remaining autonomy percentage (< 100, 75, 50, 25%): shown < 50% 128V rated rated 102V your devices are powered by the battery 92 Volts min with utility power maxi (**) mini (**) "booster" mode in operation (*) (*) outside the min.-max.
operation with battery back up time no utility power power failure low battery warning 0 min Pulsar switches off automatically if Pulsar is operating off load: device switches off (*) x + ε min x min 5 min indicating the remaining autonomy time: here, between 75 and 50% 1 beep every 3 s 1 beep every 10 s your load is powered by the battery discontinue use of load, battery is near exhaustion silence silence your load is no longer powered your load is no longer powered (*) configuration via ES
overload operating anomalies utility power present device fault battery fault A battery test is carried out while Pulsar, is in start-up phase, then automatically every 7 days (overhaul times adjustable using ESV Driver).
battery replacement ESV8+Rack / 11+Rack / 14+Rack /22+Rack ■ see important battery safety rules (see page i); ■ batteries can be replaced without risk, but don't hesitate to contact our after sales department to confirm battery failure, and to give you further information; ■ battery replacement can be performed with UPS on utility power, but we recommend you to switch off the unit in order to avoid any data loss; ■ use a screwdriver to remove the cover on the right side of the UPS ESV+Rack; ■ use a screwdri
technical data ■ output power: ■ Pulsar ESV 8+Rack: ■ Pulsar ESV 11+Rack 780VA/490W 1080VA/700W ■ ■ ■ ■ ■ utility power source: voltage (V): frequency (F): battery: type: ■ ■ ■ ■ ■ ■ output specifications with load on battery: voltage (V): single phase 120V ±5% (**) frequency (F): 50Hz/60Hz ± .
technical data (continued) Pulsar ESV 8+Rack battery back-up time Pulsar ESV 11+Rack /14+Rack battery back-up time Pulsar ESV 22+Rack battery back-up time ESV11+Rack 2 desktop servers 2 tower servers 2 tower servers + external mass storage ESV14+Rack tower server + external mass storage tower server + 12 port Hub tower server + external mass storage system tower server + 12 port Hub 4 stack Hub tower server + Hub tower server tower server desktop server 0 22 5 10 15 desktop server t (mn
North American warranty MGE UPS Systems warrants that products furnished hereunder shall be free of defects in material and workmanship for a period of two (2) years from date of purchase. Upon notice of any such defect, MGE UPS Systems shall, at its option, repair or replace the defective product at no cost to the buyer. Proven defective units will be replaced with new or re-certified units, at MGE’s sole option.
Austria : 0660 6215 Belgium : 0800 7 2189 China/Hong Kong : (852) 2 811 2399 Denmark : 8001 0137 France : 0800 33 68 58 Germany : 0130 81 9431 Italy : 1678 700 98 Netherlands : 06022 3057 North America : 1 800 438 7373 Norway : 800 11 221 United Kingdom : 0800 96 8558 South-East Asia (Singapore) : (65) 288 43 23 Spain : 900 99 3384 Sweden : 020 795 475 Switzerland : 155 1107 Other countries : (33) (0)4 76 33 91 36 As standard, specifications and designs change from time to time, please ask for confirmatio