Pulsar EXtreme 1500/2000/2500/3000 VA installation and user manual 51033211EN/AA - Page 1
Introduction Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment. The Pulsar EXtreme range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS. MGE UPS SYSTEMS pays great attention to the environmental impact of its products.
Safety Safety rules Safety of persons A UPS has its own internal power source (the battery). Consequently, the power outlets may be energized even if the UPS is disconnected from the AC-power source. Dangerous voltage levels are present within the UPS. It should be opened exclusively by qualified service personnel. The UPS must be properly earthed.
Foreword Using this document Information may be found primarily by consulting: ◗ the contents; ◗ the index. Pictograms Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing.
Contents 1. Presentation 1.1 Pulsar EXtreme range ................................................................................................................. 7 Tower model .................................................................................................................................... 7 Rack model ..................................................................................................................................... 7 1.2 Connection modules .........................
Contents 3.4 Failure of AC input power and operation on battery power .................................................... 20 Transfer to battery power .............................................................................................................. 20 Threshold for the low-battery shutdown warning .......................................................................... 20 End of backup time .....................................................................................................
1. Presentation 1.
1. Presentation 1.2 Connection modules Fault tolerant 1 socket for connection to AC-power source. 2 outlets for direct connection to protected equipment. 3 manual bypass switch. 1 2 Hot swap 3 1 5 2 Install 3 5 4 Page 8 - 51033211EN/AA 4 input terminal block with cable clamp. 5 output terminal block with cable clamp.
1. Presentation 1.3 Back 6 slot for communications-card option. 7 battery module connector. 8 battery circuit breaker. 9 rating plate. 10 connector for connection modules. 11 RS232 communications port.
1. Presentation 1.4 Control panel Page 10 - 51033211EN/AA Alarms % battery ␣ ␣ remaining % load 14 UPS overload 100% 100% 15 electronics fault 80% 80% 16 battery fault 50% 50% 17 ambient temp. > 40°C 20% 20% 18 hold down to display percent load. 19 lamp test or buzzer OFF. 20 operation on manual bypass. 21 operation in ECO mode. 22 operation in ON-LINE mode. 23 operation on battery power. 24 ON/OFF.
2. Installation 2.1 Unpacking and checks Tower model 29 26 25 27 28 25 RS 232 communications cable. 26 "Solution Pac" CD ROM. 27 "UPS Driver" diskette for UPS personalization. 28 documentation. 29 electrical power cord (except INSTALL version).
2. Installation Rack model 30 29 26 25 25 RS 232 communications cable. 26 "Solution Pac" CD ROM. 27 "UPS Driver" diskette for UPS personalization. 28 documentation. 29 electrical power cord (except INSTALL version). 30 telescopic rails for mounting in 19" bay with mounting hardware.
2. Installation 2.2 Installation (rack version) Rack mounting diagram with rails. 1 3 3 3 4 3 2 The rails and the necessary mounting hardware are supplied with the UPS in the package.
2. Installation 2.3 Connection to the RS 232 communications port (optional) 1. Connect the RS 232 communications cable 25 to the serial port on the computer. 2. Connect the RS 232 communications cable 25 to the RS 232 communications port 11 on the UPS. The UPS can now communicate with all MGE UPS SYSTEMS supervision, set-up or safety software. Pin-out diagram for the RS 232 communications port 11 on the UPS. RD TD OV 5 4 9 3 2 8 1 7 6 RTS 2.
2. Installation 2.5 Securing and connecting the connection modules Securing the connection modules 1. Insert the connection module in the connector 10 . 10 2. Secure the connection module to the UPS using the two screws 31 . 31 31 Fault tolerant Before carrying out any connections, check that the battery circuit breaker 8 electrical power cord to the AC-power source is disconnected. is OFF and that the Connection of equipment: Connect the protected equipment directly to the outlets 2 .
2. Installation Hot swap Before carrying out any connections, check that the battery circuit breaker 8 is OFF and that the electrical power cord to the AC-power source is disconnected. Connection of equipment to outlets Plug your equipment into the outlets 2 . 2 8 32 33 Connection of equipment to a terminal block: This type of connection must be carried out by qualified electrical personnel. 1. Remove the terminal-block cover 32 . 2. Insert the cable supplying the equipment through the cable clamp 33 .
2. Installation Install This type of connection must be carried out by qualified electrical personnel. Before carrying out any connections, check that the battery circuit breaker 8 is OFF and that the upstream protection devices (AC distribution system) are open (OFF). 8 The overall cable diameter and the cross-sectional area of the three wires depends on the UPS rating.
3. Operation 3.1 Operating mode ON-LINE mode This is the standard operating mode, set by default in the factory. It makes use of electronic double conversion of the input power. Two possible cases: 22 LED 22 is ON: AC input power is available. Power is drawn from the distribution system and supplied to the protected equipment via the UPS. LED 23 is ON: AC input power is not available. Power is drawn from the battery and supplied to the protected equipment.
3. Operation 3.2 Start-up The protected equipment connected to the UPS can be energized, whether AC input power is available or not. Prior to initial start-up, check the UPS voltage settings. If the protected equipment voltage is other than 230 V / 50 Hz, the UPS settings must be modified using the "UPS Driver" software 27 (see section 3.5). 1. Set the battery circuit breaker(s) 8 to ON. 8 2. Press the ON / OFF button 24 . All connected equipment is energized. The buzzer sounds. LEDs 21 , 22 and 23 go ON.
3. Operation 3.4 Failure of AC input power and operation on battery power AC input power is not available, the battery steps in to supply the protected equipment. Transfer to battery power The AC-power source is outside tolerances, LED 23 is ON, the buzzer beeps three times. 23 Threshold for the low-battery shutdown warning The low-battery shutdown warning threshold can be set by the user, with the "UPS Driver" software (see section 3.5). LED 23 flashes. The buzzer beeps every three seconds.
3. Operation 3.5 Personalization Function Personalization parameters can be set and modified using the "UPS Driver" software installed on a computer that is connected to the UPS (see section 2.3 Connection to the RS 232 communications port). Check that the RS 232 cable 25 is correctly connected and that the battery circuit breaker 8 is closed. "UPS Driver" installation: 1. Insert the "UPS Driver" diskette in the drive of an IBM-compatible microcomputer. 2. Select the disk drive (A :\). 3.
3. Operation "Battery" tab Personalizable function Default setting Options "Battery test" intervals Every day Once a week Once a month No test "Low-battery shutdown warning" threshold 20% remaining battery backup time 40% remaining battery backup time Charger Standard CLA (2, 4 or 8 hours) "Output" tab Rated AC-power source voltage (see figure 1) 230 V 200 V-208 V-220 V-240 V Rated AC-power source frequency 50 Hz 60 Hz Tolerance for AC-power source frequency (fig.
3. Operation "ECO mode" tab ECO mode is not possible unless it has first been authorized using the "UPS Driver" software Personalizable function Default setting Options ECO mode authorization Disabled (not authorized) Enabled (click to check) Authorized voltage range for operation in ECO mode (see figure 3) Range for minimum authorized voltage for operation in ECO mode 200 V to 240 V (for 230 V rated voltage) The upper threshold (max.
4. Maintenance 4.1 Troubleshooting If any of LEDs 14 , 15 , 16 or 17 flash, there is a operating anomaly or an alarm. If a LED flashes, the bargraph data is no longer displayed. Troubleshooting not requiring MGE after-sales support Indication Signification LED 14 flashes and the buzzer UPS overload. Overload is too long beeps. or too high. The UPS cuts the supply of power to the connected equipment and the buzzer sounds continuously. The ambient temperature is higher than 40° C. LED 17 flashes.
4. Maintenance Troubleshooting requiring MGE after-sales support Indication Signification LED 15 flashes and the buzzer beeps. UPS electronics have detected a UPS fault. Depending on the UPS personalization parameters (see section 3.
4. Maintenance 4.2 UPS replacement Fault-tolerant connection module Before carrying out this operation, the supply of power to the connected equipment must be cut. 24 8 Disconnection: 1. Shut down the UPS by pressing button 24 (return to the OFF position). 2. Open the battery circuit breaker(s) 8 . 3. Remove the two fixing screws 31 and the connection module from the UPS. Reconnection: 1. Insert the connection module in the connector 10 and secure using the two screws 31 . 2.
4. Maintenance Hot-swap and Install connection modules Disconnection: 1. Turn the manual bypass switch 3 from the NORMAL to the intermediate position. 2. Check that LED 21 is ON before continuing to the BYPASS position. Before turning the switch, see the manual NORMAL BY-PASS 20 21 Before turning the switch, see the manual NORMAL BY-PASS If LED 21 is not ON, do not switch to the BYPASS position and call the after-sales support department. 3.
5. Environment This product has been designed to respect the environment: It does not contain CFCs or HCFCs. It was manufactured in a factory certified ISO 14001. UPS recycling at the end of service life: MGE UPS SYSTEMS undertakes to recycle, by certified companies and in compliance with all applicable regulations, all UPS products recovered at the end of their service life (contact your branch office). Packing: UPS packing materials must be recycled in compliance with all applicable regulations.
6. Appendices 6.1 Glossary Authorized voltage range for operation in ECO mode The range of voltage supplied by the AC-power source within which the UPS can operate in ECO mode. In ECO mode, the equipment connected to the UPS is supplied directly by the AC-power source, via the automatic bypass. Authorized voltage range for transfer to bypass if fault or overload Upper and lower voltage thresholds within which the UPS can operate on the automatic bypass in the event of a UPS fault or overload.
6. Appendices Frequency-regulation rate The rate at which the UPS frequency is synchronized with that of the AC-power source. Two possible cases: 1. The installation comprises a single UPS. The frequency-regulation rate is set to "Standard". 2. The installation comprises two UPSs connected in series. The AC-power source supplies power to the first UPS which in turn supplies the second UPS. The connected equipment is supplied by the second UPS.
6. Appendices 6.2 Index A L AC power Failure ........................................................... 20 Frequency tolerance ..................................... 22 Rated frequency ............................................ 22 Rated voltage ................................................ 22 Return ............................................................ 20 LEDs Lamp test ....................................................... 10 M Mode ECO mode ..........................................
140, Avenue Jean Kuntzmann ZIRST - Montbonnot St Martin 38334 - ST ISMIER CEDEX - FRANCE www.mgeups.com 51033211EN/AA Page 32 - 51033211EN/AA Nothing will stop you now Publication : MGE UPS SYSTEMS, 11/99.
Pulsar EXtreme 1500/2000/2500/3000 VA Installations- und Bedienungsanleitung 51033211DE/AA - Page 1
Einleitung Wir danken Ihnen, daß Sie sich für ein Produkt von MGE UPS SYSTEMS zum Schutz Ihrer Anwendungen entschieden haben. Die Baureihe Pulsar EXtreme wurde mit größter Sorgfalt entwickelt. Um die Leistungen Ihrer USV (Unterbrechungsfreien Stromversorgung) optimal nutzen zu können, empfehlen wir Ihnen, sich ein wenig Zeit zu nehmen und das vorliegende Handbuch aufmerksam zu lesen. Für MGE UPS SYSTEMS ist Umweltschutz ein wichtiger Aspekt bei der Entwicklung und Herstellung seiner Produkte.
Sicherheit Sicherheitsregeln Personenschutz Die USV verfügt über eine eigene interne Energiequelle (Batterie). Die Abgangssteckdosen können daher unter Spannung stehen, selbst wenn die USV vom Leitungsnetz getrennt ist. Gefährliche Spannung im Innern der USV. Öffnen des Gehäuses darf nur durch Fachpersonal erfolgen. Die USV muß in jedem Fall gemäß den gültigen Vorschriften geerdet werden.
Vorbemerkungen Aufbau der Installations- und Bedienungsanleitung Die Suche nach bestimmten Informationen erfolgt auf einfachste Weise: ◗ über das Inhaltsverzeichnis, ◗ über das Stichwortregister.
Inhalt 1. Ansichten und Beschreibung 1.1 Die Baureihe Pulsar EXtreme .................................................................................................... 7 Tower-Modell ................................................................................................................................... 7 Rack-Modell .................................................................................................................................... 7 1.2 Anschlußmodule .......................
Inhalt 3.4 Batterieversorgung der Verbraucher bei Netzausfall .............................................................. 20 Umschaltung auf Batteriebetrieb ................................................................................................... 20 Voralarm "Ende der Autonomiezeit" .............................................................................................. 20 Abschaltung am Ende der Autonomiezeit ..............................................................................
1. Ansichten und Beschreibung 1.
1. Ansichten und Beschreibung 1.
1. Ansichten und Beschreibung 1.
1. Ansichten und Beschreibung 1.
2. Aufstellung und Installation 2.
2.
2. Aufstellung und Installation 2.2 Einbau des Rack-Modells Einbau und Befestigung der Teleskopschienen und der Rack. 1 3 3 3 4 3 2 Befestigungsschrauben und Teleskopschienen liegen dem Gerät bei.
2. Aufstellung und Installation 2.3 Anschluß des RS232-Kommunikationskabels (wahlweise) 1. Kommunikationskabel 25 an die serielle Schnittstelle des zu schützenden Systems anschließen. 2. Kommunikationskabel 25 an die RS232-Schnittstelle 11 der USV anschließen. Die USV kann nun über verschiedene Softwarepakete von MGE UPS SYSTEMS mit dem angeschlossenen Rechnersystem kommunizieren (Überwachung, Konfiguration, Sicherheitsparameter). Anschlußbelegung der USV RS232-Schnittstelle 11 .
2. Aufstellung und Installation 2.5 Montage der Anschlußmodule Befestigung der Anschlußmodule 1. Anschlußmodul auf den Steckverbinder 10 aufstecken. 10 2. Anschlußmodul mit 2 Schrauben 31 an der USV befestigen. 31 31 Fault tolerant Modul Vor dem Anschluß ist sicherzustellen, daß der Batterie-Leistungsschalter 8 in OFF-Stellung steht und das Netzkabel nicht angeschlossen ist. Anschluß der Verbraucher: Verbraucher direkt an die Abgangssteckdosen 2 anschließen. 2 1 Netzanschluß: 29 1.
2. Aufstellung und Installation Hot-Swap Modul Vor dem Anschluß ist sicherzustellen, daß der Batterie-Leistungsschalter 8 in OFF-Stellung steht und das Netzkabel nicht angeschlossen ist. Anschluß der Verbraucher über Abgangssteckdosen: Verbraucher direkt an die Abgangssteckdosen 2 anschließen. 2 8 32 Anschluß der Verbraucher über Klemmleiste: Dieser Anschluß darf nur von qualifiziertem Fachpersonal durchgeführt werden. 1. Klemmenabdeckung 32 entfernen. 2.
2. Aufstellung und Installation Install Modul Dieser Anschluß darf nur von qualifiziertem Fachpersonal durchgeführt werden. Vor dem Anschluß ist sicherzustellen, daß der Batterie-Leistungsschalter 8 in OFF-Stellung steht und die netzseitigen Schutzorgane ausgeschaltet sind. 8 Kabeldurchmesser und Leiterquerschnitte hängen von der Nennleistung der USV ab.
3. Betriebszustände 3.1 Betriebsarten ONLINE-Mode Diese Betriebsart ist werksseitig voreingestellt. Dabei arbeitet die USV nach dem Doppelwandlerprinzip. Es können zwei Betriebszustände vorliegen: 22 LED 22 leuchtet: Das Einspeisenetz ist vorhanden (Normalbetrieb). Das Einspeisenetz versorgt über die USV die Verbraucher. LED 23 leuchtet: Das Einspeisenetz ist nicht vorhanden (Batteriebetrieb). Die Batterie versorgt über die USV die Verbraucher .
3. Betriebszustände 3.2 Inbetriebnahme der USV Die an die USV angeschlossenen Verbraucher können unabhängig vom Vorhandensein des Einspeisenetzes eingeschaltet werden. Vor dem ersten Einschalten der USV ist die Einstellung der Netzspannung zu überprüfen. Werden die Verbraucher nicht mit 230 V / 50 Hz eingespeist, müssen die entsprechenden USVParameter über die Software "UPS Driver" 27 angepaßt werden (siehe Abschnitt 3.5). 1. Batterie-Leistungsschalter 8 einschalten (Stellung ON). 8 2.
3. Betriebszustände 3.4 Batterieversorgung der Verbraucher bei Netzausfall Bei Netzausfall werden die an die USV angeschlossenen Verbraucher unterbrechungsfrei über die Batterie weiter versorgt. Umschaltung auf Batteriebetrieb Das Einspeisenetz liegt außerhalb der zulässigen Toleranzen, die Anzeige 23 leuchtet auf und der Summer erzeugt 3 Pieptöne. 23 Voralarm "Ende der Autonomiezeit" Der Alarmgrenzwert kann über die Software "UPS Driver" kundenspezifisch angepaßt werden (siehe Abschnitt 3.5).
3. Betriebszustände 3.5 Kundenspezifische Anpassung per Software Software, Installation und Funktion Die kundenspezifische Anpassung der USV kann mit Hilfe der Software "UPS Driver" über einen Rechner erfolgen, der über die serielle Kommunikationsschnittstelle mit der USV verbunden ist (siehe Abschnitt 2.3). Das RS232-Kommunkationskabel 25 muß angeschlossen und der Batterie-Leistungsschalter 8 eingeschaltet sein. Installation der Software "UPS Driver": 1.
3. Betriebszustände Registerkarte "Batterie" Einstellungen Default-Einstellung Mögliche Einstellwerte Zeitintervall für Batterietest täglich einmal wöchentlich einmal monatlich kein Test Grenzwert Voralarm "Ende der Autonomiezeit" 20% Restautonomiezeit 40% Restautonomiezeit Ladegerät Standard CLA (2, 4 oder 8 Std.) Registerkarte "Ausgang" Nennspannung des Einspeisenetzes (Abb.
3. Betriebszustände Registerkarte "ECO-Mode" Der ECO-Mode kann nur über die Software "UPS Driver" eingestellt werden. Einstellungen Default-Einstellung Mögliche Einstellwerte Freigabe des ECO-Mode keine Freigabe (unzulässig) freigegeben (Optionsfeld anklicken) Zulässiger Spannungsbereich für Umschaltung auf ECO-Mode (siehe Abb.
4. Wartung und Service 4.1 Fehlerbehebung Das Blinken einer der LEDs 14 , 15 , 16 oder 17 zeigt eine Betriebsstörung oder einen Alarmzustand an. Sobald eine der LEDs blinkt, ist die Balkenanzeige für Autonomiezeit/Auslastungsgrad nicht mehr aktiv. Fehlerbehebung ohne Inanspruchnahme des MGE Kundendiensts Fehleranzeige LED 14 blinkt und Summer ertönt. LED 17 blinkt.
4. Wartung und Service Fehlerbehebung, die eine Inanspruchnahme des MGE UPS SYSTEMS Kundendienstes erfordert Fehleranzeige LED 15 blinkt und Summer ertönt. Fehlerursache Je nach kundenspezifischer Einstellung der USV (siehe Abschnitt 3.5) können zwei Situationen eintreten: ◗ Die Versorgung sämtlicher an die USV angeschlossenen Systeme bleibt aufrecht erhalten, erfolgt jedoch über die automatische NRE (LED 21 leuchtet). ◗ Die Versorgung sämtlicher angeschlossenen Systeme ist unterbrochen.
4. Wartung und Service 4.2 Austausch der USV Fault tolerant-Version Vor dem Austausch muß die Energieversorgung der Verbraucher abgeschaltet werden. 24 8 Vorhandene USV abklemmen: 1. USV durch Betätigung der EIN/AUS-Taste 24 ausschalten (Taste ausgerastet). 2. Batterie-Leistungsschalter 8 ausschalten. 3. Anschlußmodul durch Herausdrehen der 2 Schrauben 31 von der USV lösen. Wiederanschluß der neuen USV: 1. Anschlußmodul auf den Steckverbinder 10 stecken und mit 2 Schrauben 31 befestigen. 2.
4. Wartung und Service Hot-Swap- und Install-Version Vorhandene USV abkemmen: 1. Handumgehung 3 von der Stellung "NORMAL" auf die Zwischenstellung schalten. 2. Vor dem Umschalten in die Stellung "BY-PASS" prüfen, ob LED 21 leuchtet. Vor Umschaltung, Hinweis! beachten! NORMAL BY-PASS 20 21 Vor Umschaltung, Hinweis! beachten! NORMAL BY-PASS Falls die LED 21 NICHT leuchtet, Handumgehung NICHT in die Stellung "BY-PASS" umschalten und Kundendienst benachrichtigen. 3.
5. Umweltschutz Das vorliegende Produkt wurde im Hinblick auf seine Umweltverträglichkeit entwickelt: Es enthält weder FKW- noch FCKW-Verbindungen. Seine Herstellung erfolgte in einer Produktionsstätte gemäß ISO 14001.
6. Anhang 6.1 Fachbegriffe Anschlußmodul Modul mit netz- und lastseitigen Anschlüssen. Auslastungsgrad Verhältnis der durch die angeschlossenen Verbraucher aufgenommenen Leistung zur verfügbaren USV-Nennleistung. Ausrüstungen An die USV angeschlossene Geräte und Verbraucher. Automatische Netzrückschalteinrichtung Über die USV gesteuerter, automatischer Umschalter zur direkten Verbraucherversorgung aus dem Einspeisenetz.
6. Anhang Hot Swap USV-Version bzw. Anschlußmodul mit Handumgehung für Netz- und Verbraucheranschluß über Steckdose. Install USV-Version bzw. Anschlußmodul mit Handumgehung für Netz- und Verbraucheranschluß über Anschlußklemmen. Kaltstart Siehe "Start im Batteriebetrieb". Kundenspezifische Anpassung Bestimmte USV-Funktionen können über die Software "UPS Driver" an individuelle Kundenbedürfnisse angepaßt werden. Registerkarte Bildschirmdarstellung einer Software zur Auswahl bestimmter Optionen.
6. Anhang 6.2 Stichwortregister A Alarmton (Summer) ..................................... 4-10-20 Anschlüsse Anschlußmodul ........................................ 16-17 Kommunikationskarte .................................... 14 RS232-Kommunikationsschnittstelle ............. 14 Ausschalten der USV ...................................... 10-23 Ausschalten der USV über Software ................... 21 Automatische Netzrückschalteinrichtung (NRE) ................................................................
140, Avenue Jean Kuntzmann ZIRST - Montbonnot St Martin 38334 - ST ISMIER CEDEX - FRANCE www.mgeups.com 51033211DE/AA Seite 32 - 51033211DE/AA Nichts hält Sie mehr auf Verantwortlich Publication : MGE UPS SYSTEMS, 10/99.