Instruction manual
74
16.7.6  Terminal Selection Parameters 
Parameter  Function / Title  Bank  Mask  Adjustment Range  Multiplier 
0044 
INPUT TERMINAL 
SELECTION 
0 / 1  0001  0000: Standard functions  (0) 
0001: Individual selections  (1) 
⎯ 
0045 
“R” INPUT TERMINAL 
FUNCTION 
0 / 1  FFFF 
0000 ∼ FFFF (0 ∼ 54)  ⎯ 
0046 
“S1” INPUT 
TERMINAL FUNCTION 
    Refer to Table 9 (page 76)   
0047 
“S2” INPUT 
TERMINAL FUNCTION 
0048 
“S3” INPUT 
TERMINAL FUNCTION 
0049 
“S4” INPUT 
TERMINAL FUNCTION 
004A 
“F” INPUT TERMINAL 
FUNCTION 
004B 
“RES” INPUT 
TERMINAL FUNCTION 
004C 
“ST” INPUT 
TERMINAL FUNCTION 
004D 
“S5” INPUT 
TERMINAL FUNCTION 
004E 
“S6” INPUT 
TERMINAL FUNCTION 
004F 
“S7” INPUT 
TERMINAL FUNCTION 
0050 
1 
POTENTIAL TERMINAL 
FUNCTION 
0051 
R,S1-S7 TERMINAL 
RESPONSE TIME 
0 / 1  00FF 
0001 ∼ 0064 (1 ∼ 100) 
1 
0052 
F INPUT TERMINAL 
RESPONSE TIME 
0 / 1  00FF 
0001 ∼ 0064 (1 ∼ 100) 
1 
0053 
RES INPUT TERMINAL 
RESPONSE TIME 
0 / 1  00FF 
0001 ∼ 0064 (1 ∼ 100) 
1 
0054 
ST INPUT TERMINAL 
RESPONSE TIME 
0 / 1  00FF 
0001 ∼ 0064 (1 ∼ 100) 
1 
0055 
“RCH” CONTACTS 
FUNCTION 
0 / 1  FFFF 
0 ∼ FFFF (0 ∼ 63) 
Refer to Table 10 (page 77) 
⎯ 
0056 
“RCH” CONTACTS DELAY 
TIME 
0 / 1  00FF 
0001 ∼ 0064 (1 ∼ 100) 
1 
0057 
“RCH” CONTACTS HOLD 
TIME 
0 / 1  00FF 
0001 ∼ 0064 (1 ∼ 100) 
1 
0058 
“LOW” CONTACTS 
FUNCTION 
0 / 1  FFFF 
0 ∼ FFFF (0 ∼ 63) 
Refer to Table 10 (page 77) 
⎯ 
0059 
“LOW” CONTACTS DELAY 
TIME 
0 / 1  00FF 
0001 ∼ 0064 (1 ∼ 100) 
1 
005A 
“LOW” CONTACTS HOLD 
TIME 
0 / 1  00FF 
0001 ∼ 0064 (1 ∼ 100) 
1 
005B 
“FL” CONTACTS FUNCTION 
0 / 1  FFFF 
0 ∼ FFFF (0 ∼ 63) 
Refer to Table 10 (page 77) 
⎯ 
005C 
“FL” CONTACTS DELAY 
TIME 
0 / 1  00FF 
0001 ∼ 0064 (1 ∼ 100) 
1 
005D 
“FL” CONTACTS HOLD 
TIME 
0 / 1  00FF 
0001 ∼ 0064 (1 ∼ 100) 
1 
005E 
“OUT” CONTACTS 
FUNCTION 
0 / 1  FFFF 
0 ∼ FFFF (0 ∼ 63) 
Refer to Table 10 (page 77) 
⎯ 
005F 
“OUT” CONTACTS DELAY 
TIME 
0 / 1  00FF 
0001 ∼ 0064 (1 ∼ 100) 
1 
0060 
“OUT” CONTACTS HOLD 
TIME 
0 / 1  00FF 
0001 ∼ 0064 (1 ∼ 100) 
1 