Instruction manual
87
16.7.11  Feedback Control Parameters 
Parameter  Function / Title Bank Mask Adjustment Range Multiplier 
0190 
FEEDBACK CONTROL 
SELECTION 
0 / 1  0060  0020: No feedback  (0) 
0040: PID control  (1) 
0060: Speed feedback  (2) 
⎯ 
0191 
FEEDBACK INPUT 
SIGNAL 
SELECTION 
0 / 1  001C  0004:  RR input  (1) 
0008: IV input  (2) 
000C: RX input  (3) 
0010: PG feedback  (4) 
0014: RS232C input  (5) 
0018: Communication/12-bit binary 
interface board  (6) 
001C: BIN input  (7) 
⎯ 
0192 
PROPORTIONAL 
GAIN 
0 / 1  00FF 
0001 ∼ 00FF (0.01 ∼ 2.55) 
0.01 
0193 
INTEGRAL GAIN 
0 / 1  FFFF 
0001 ∼ 8CA0 (0.01 ∼ 360.00) 
0.01 
0194 
ANTI-HUNTING 
GAIN 
0 / 1  00FF 
0000 ∼ 00FF (0.0 ∼ 25.5) 
0.1 
0195 
LAG TIME 
CONSTANT 
0 / 1  00FF 
0000 ∼ 00FF (0 ∼ 255) 
1 
0196 
1, 
2 
PID LOWER LIMIT 
FREQUENCY 
0 / 1  FFFF 
0 ∼ Fmax 
0.01 
0197 
PID DEVIATION LIMIT 
SELECTION 
0 / 1  0080  0000: No PID deviation limit  (0) 
0080: PID deviation limited  (1) 
⎯ 
0198 
PID DEVIATION 
UPPER LIMIT 
0 / 1  00FF 
0000 ∼ 0032 (0 ∼ 50) 
1 
0199 
1 
PID DEVIATION 
LOWER LIMIT 
0 / 1  00FF 
0000 ∼ 0032 (0 ∼ 50) 
1 
019A 
PG INPUT: NUMBER OF 
PULSES 
0 / 1  FFFF 
0001 ∼ 270F (1 ∼ 9999) 
1 
019B 
PG INPUT: NUMBER OF 
PHASES 
0 / 1  0001  0000: Single-phase input  (1) 
0001: Two-phase input  (2) 
⎯ 
019C 
DROOPING CONTROL 
ENABLE 
0 / 1  0002  0000: OFF  (0) 
0002: ON  (1) 
⎯ 
019D 
1 
DROOPING 
CONTROL AMOUNT 
0 / 1  00FF 
0000 ∼ 0064 (0 ∼ 10.0) 
0.1 
019E 
OVERRIDE CONTROL 
SELECTION 
0 / 1  0007  0000: OFF  (0) 
0001: FCRR  (1) 
0002: FCIV  (2) 
0003: FCRX  (3) 
0004: FCPG  (4) 
0005: FCPNL  (5) 
0006: FCOPT  (6) 
0007: FCMLT  (7) 
⎯ 
019F 
OVERRIDE 
MULTIPLIER 
INPUT SELECTION 
0 / 1  0038  0000: Reference  (0) 
0008: KRR  (1) 
0010: KIV  (2) 
0018: KRX  (3) 
0020: KBIN  (4) 
⎯ 
01A0 
7 
OVERRIDE CHANGE 
MULTIPLIER 
0 / 1  FFFF 
FC18 ∼ 03E8 (-100.0 ∼ 100.0) 
0.1 
01A1 ∼ 
0203 
Reserved 
⎯  ⎯  ⎯  ⎯ 