Instruction manual
51
3
OPERATION/CONTROL
3.2.4 Frequency setting
In the PU operation mode, set the frequency value used for operation performed under
the operation command given by the key ( or key).
This mode is displayed only in PU operation.
3.2.5 Parameter setting method
With the exception of some parameters, parameter setting can be made when the PU
operation mode is selected by the Pr. 79 setting.
(Also, as other to set method independently of the operation mode, you can set "2" in
Pr. 77. Refer to page 110.)
• A parameter value may either be set by updating its parameter number or setting the
value digit-by-digit using the key.
• To write the setting, change it and press the key for about 1.5 s.
Note: If parameter write cannot be performed, refer to page 176.
RUN
FWD
REV
To 3.2.5 Parameter setting mode
MODE
Hz
PU
MODE SET REV
STOP
RESET
FWD
Frequency setting mode
Set frequency changing
SET
To frequency monitoring
MODE
Hz
PU
Set frequency
write
Flicker
Hz
PU
Hz
PU
Change the set
frequency with
/
SET