Technical data
7.
Technical documentation
ProCon
HT
150
/
HT
225
Line
Level
Func
tion
Range
Valu
e
619
Specialist
F
unct.
output1
Relay clip-in.
(0:
Off,
1:
Message display.,
2:
Alarm signal,
3:
Operation message
,
4:
ex
t.
Transf.,
5:
Q2Y2,
6:
DW Circ.
.,
7:
Curtain,
8:
hydr.
switch,
9:
RegCI,
10:
Basic funct. K2,
11:
DW
- Loading Through (Durc
hldg),
12:
Analogue threshold
)
0
...
255
0
620
Specialist
F
unct. output 2
Relay clip-in.
(0:
Off,
1:
Message display,
2:
Alarm signal,
3:
Operation message
,
4:
ex
t.
Transf.,
5:
Q2Y2,
6:
DW Circ.
.,
7:
Curtain,
8:
Hydr.
switch,
9:
RegCI,
10:
Basic funct.K2,
11:
DW
- Loading Through (Durc
hldg),
12:
Analogue thres
hold
)
0
...
255
0
621
Specialist
Funct. output
3
Relay clip-in.
(0:
Off,
1:
Message display.,
2:
Alarm signal.,
3:
Operation display
,
4:
ex
t.
Transf.,
5:
Q2Y2,
6:
DW Circ.
.,
7:
Curtain,
8:
Hydr.
switch,
9:
RegCI,
10:
Basic funct.K2,
11:
DW
- Loading Through (Durc
hldg),
12:
Analogue threshold
)
0
...
255
0
622
Specialist
Heat request-Maximum value at spec. external temperature set point value
(5°C<=TReqExtMax<=130°C)
5
...
130°C
85°C
630
Specialist
Adjustment flags
of maintenance messages,
(Bit
6
on
1
for exiting
,
automatically
goes to 0 after exiting the parameters.)
0
...
255
00000001
636
Specialist
Months
(interval)
since last maintenance
0
...
255
12
Months
Error status memory of the
LMU
(Parameters
700...717
und
728
...733)
700
Specialist
1.
Past value
Error code counter
0
701
Specialist
1.
Past value
Error phase
0
702
Specialist
1.
Past value
Diagnosis code
0
703
Specialist
2.
Past value
Error code counter
0
704
Specialist
2.
Past value
Error phase
0
705
Specialist
2.
Past value
Diagnosis code
0
706
Specialist
3.
Past value
Error code counter
0
707
Specialist
3.
Past value
Error phase
0
708
Specialist
3.
Past value
Diagnosis code
0
709
Specialist
4.
Past value
Error code meter
0
710
Specialist
4.
Past value
Error phase
0
711
Specialist
4.
Past value
Diagnosis code
0
712
Specialist
5.
Past value
Error code meter
0
713
Specialist
5.
Past value
Error phase
0
714
Specialist
5.
Past value
Diagnosis code
0
715
Specialist
Present value
Error code meter
0
716
Specialist
Present value
Error phase
0
717
Specialist
Present value
Diagnosis code
0
718
Specialist
Operating hours
Burner
(Total length of time burner is
ON)
0
...
131070
Hours
719
Specialist
Operating hours
Heating operation
0
...
131070
Hours
720
Specialist
Operating hours
Domestic water operation
0
...
131070
Hours
721
Specialist
Operating hours
Zone
0
...
131070
Hours
722
Specialist
Start-up
Burner
0
...
327675
727
Display
of the d
iagnosis codes
for the present
error c
ode;
(0
=
No error present)
0
...
583
728
Specialist
1.
Past value
Error
code
0
729
Specialist
2.
Past value
Error
code
0
730
Specialist
3.
Past value
Error
code
0
731
Specialist
4.
Past value
Error
code
0
732
Specialist
5.
Past value
Error
code
0
733
Specialist
Present value
Error code
0
755
Specialist
Ionization flow
In
µA
58