Technical data
6
GEMINI HSC
7.0 technical
data
60 - i
55
12.09
22
4.83
0.6
6.45
17
58,000
15
0.6
103
22.65
346
76.11
291
64.01
16
11.2
38,214
4
0.15
87
19.13
246
54.33
192
42.23
24
8.96
30,571
4
0.15
80
17.72
208
45.88
153
33.78
30
90
194
3.0
44
8.0
116
32/109
71/241
100 - i
100
22.0
32
7.03
1.0
10.76
35
119,420
237
9.33
200
44.0
699
153.76
599
131.76
14
23.06
78,680
60
2.4
165
36.49
495
108.95
395
86.95
20
18.45
62,951
60
2.4
152
33.6
416
91.57
316
69.57
25
90
194
3.0
44
8.0
116
48/180
106/397
150 - i
150
33.0
44
9.67
1.2
12.91
33
112,596
79
3.11
244
53.67
715
157.28
565
124.28
21
21.74
74,176
20
0.78
212
46.65
522
114.97
372
81.97
31
17.39
59,334
20
0.78
199
43.92
448
98.57
298
65.57
39
90
194
3.0
44
8.0
116
64/258
141/569
200 - i
200
44.0
56
12.31
1.6
17.22
44
150,128
173
6.81
325
71.5
954
209.85
754
165.86
21
28.99
98,913
44
1.73
282
62.21
696
153.31
496
109.32
31
23.2
79,158
44
1.73
266
58.57
597
131.48
397
87.48
39
90
194
3.0
44
8.0
116
78/334
172/737
300 - i
300
66.0
72
15.83
2.4
25.83
67
228,604
545
21.45
491
108.0
1448
318.52
1148
252.52
20
44.15
150,639
137
5.4
426
93.74
1056
232.48
756
166.48
30
35.32
120,511
137
5.4
400
88.19
905
199.18
605
133.18
37
90
194
3.0
44
8.0
116
109/481
241/1060
500 - i
500
110.0
98
21.55
3.1
33.36
86
293,432
338
13.3
745
163.88
1974
434.22
1474
324.24
25
56.68
193,392
85
3.4
661
145.60
1471
323.72
971
213
37
45.34
154,700
85
3.4
629
138.48
1277
280.96
777
170.97
46
90
194
3.0
44
8.0
116
151/749
333/1651
Model HSC
DHW Capacity
L
UK Gal
Primary Capacity
L
UK Gal
Heating Surface
m
2
ft
2
Heat Transfer Rate
kW
Btu/h
Primary Circuit mm, wg
Pressure Drop in wg
10min Peak Output L
at 50ºC ∆t UK Gal
1st Hour Continuous L/h
Output @ 50ºC ∆t UK Gal/h
Continuous Output L/h
at 50ºC ∆t UK Gal/h
Heat Up Time
min
10-60°C
Heat Transfer kW
Rate Btu/h
Primary Circuit mmwg
Pressure Drop in wg
10 minute peak L
Output at 50ºC ∆t UK Gal/h
1st Hour Continuous L/h
Output at 50ºC ∆t Uk Gal/h
Continuous Output L/h
at 50ºC ∆t Uk Gal/h
Heat Up Time
min
50ºC ∆t
Heat Transfer kW
Rate Btu/h
Primary Circuit mm wg
Pressure Drop in wg
10 min Peak L
Output at 50ºC ∆t UK Gal
1st Hour Continuous L/h
Output at 50ºC ∆t Uk Gal/h
Continuous Output L/h
at 50ºC ∆t Uk Gal/h
Heat Up Time
min
50ºC ∆t
Maximum Operating °C
Temperature °F
Maximum Operating bar
Pressure Primary psig
Maximum Operating bar
Pressure Secondary psig
Weight Kg
Empty/Filled lbs
Performance of the unit may vary with other operating conditions.
Performance Data When
Primary Flow 80ºC & Return 60ºC
Performance Data When
Primary Flow 85ºC & Return 65ºC
Performance Data When
Primary Flow 80ºC & Return 70ºC