"MOJO" Series Unvented Gas Log Sets
Figure 9 is an example of an unsafe mantel installation.
This mantel projects 4" at 8" above the opening, exceed-
ing the maximum acceptable distance of 2
1
/2" The mantel
also projects 7" at 14
1
/2" above the opening, exceeding the
maximum acceptable distance of 6".
If your mantel profile is unsafe, you may either:
• Raise the mantel to an acceptable height
• Remove the mantel
FP2002
mantel clearances unsafe
1456O”
256O"
8"
6"
7"
4"
Mantel
Minimum of 8"
Heat Resistant
Material
Hood
FP2002
Figure 9 -
Minimum Mantel Clearance with Hood - MJ27
(Example of Unsafe Installation)
The gas log heater must be installed at least 1
3
/8" above
any combustible flooring material, such as carpeting or
tile, which is closer than 14" to the base of the fireplace.
The minimum distance must be maintained from the top
surface of carpeting, tile, etc.
The gas log heater may be installed nearer to the floor if a
minimum of 14" of noncombustible material such as slate
or marble is installed between the base of the fireplace and
the combustible flooring.
1
3
/8" Minimum
FP2003
min clear comb floor
Heater in
Fireplace or
Firebox
Combustible
Material
FP2003
Figure 10 -
Minimum Clearance above Combustible Flooring
14" Minimum
FP2004
min clear nocomb floor
Heater in
Fireplace or
Firebox
Combustible
Material
This Distance May Now be Less
Than 1C\,"
FP2004
Figure 11 -
Minimum Clearance above Combustible Flooring with
Noncombustible Material Installed at Base of Fireplace