Operating instructions


5
"MOJO" Series Unvented Gas Log Sets



Check your packing list to verify that all listed parts have
been received. You should have the following:
Unvented Gas Log Burner Assembly
Two (2) Plastic Bags Containing Crushed Volcanic
Rock
Installation/Operating Instructions
Two (2) Anchoring Screws
Ceramic Fiber Logs Rock wool
FAI135 Andiron Kit Flickering Bright Embers
RCSIT Hand Held Remote with Receiver
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance. 



You should have the following items available before
proceeding with installation:
External regulator (for propane/LPG and 1/2 lb.
natural gas systems only)
Piping which complies with local codes
Sediment trap (recommended)
Screwdriver
Tee joint.
Pipe sealant approved for use with propane/LPG
(Resistant to sulfur compounds)
Drill with 5/32 masonry bit
Pipe wrench or appropriate size crescent
Manual shutoff valve
Wrench set
    





*Natural **Propane (LP)
Inlet Minimum 5.0” w.c. 11.0” w.c.
Inlet Maximum 10.5” w.c. 13.0” w.c.
Pilot Regulator 3.5" w.c. n/a
Regulator Pressure 4.0” w.c. 10.0” w.c.
 An external regulator is required to reduce supply
pressure to a maximum of 10Z\x" W.C. on natural gas sys-
tems operating at higher pressure.
 An external regulator is required to reduce sup-
ply pressure to a maximum of 13” w.c.


Piezo ignitor allows ignition of the pilot without the use of
matches or batteries.

 - All gas to the gas logs is shut off at the valve.
 - Valve position to light/maintain a standing pilot.
 - Valve position to light/maintain the gas burner.

The gas log heater is fitted with a specially designed
safety pilot (ODS assembly) which senses the amount of
oxygen available in the room and shuts the gas log heater
off if the oxygen level begins to drop below a satisfactory
level. The pilot can only be relit when adequate fresh air
is available.

The millivolt gas log pilot is fitted with a Millivolt (thermopile)
generator to provide power for remote activation.
Max.Input Min. Input
Model Fuel Control BTU/h BTU/h
MJ27NR Nat. Millivolt 25,500 38,000
MJ27PR LP Millivolt 29,500 37,000