Operating instructions
8
"MOJO" Series Unvented Gas Log Sets
The sides of the fire-
place opening must be at least 16" from any combustible
wall. The ceiling must be at least 42" from the top of the
fireplace opening.
minimum clearances
Follow these instructions carefully to ensure safe installation. Failure to
follow instructions exactly can create a fire hazard.
16"
42"
FP1996
wall ceiling clearances
FP1996
Figure 4 -
Sidewall and Ceiling Clearances
To install the gas logs into a fireplace with no wooden
mantel, shelf or other combustible projection above the
fireplace opening, measure the heat resistant material
height according to TABLE A.
Heat resistant materials such as slate and marble must
TABLE A -
Heat Resistant Material Requirements with no Mantel
or Combustible Projection
FP1997
heat resistant material
Heat Resistant
Material
Heater in Fireplace or
Firebox
FP1997
Measure
This
Distance
Figure 5 -
Measuring Heat Resistant Material
12” or more Hood not required
8” or less than 12” Extend heat resistant material to 12”
install hood.
Less than 8” Extend heat resistant material to at
least 8” install hood.
extend heat resistant material to a
height of at least 12".