Specifications

11

NBST27 Unvented Gas Log Set


Turn the gas supply to the fireplace or firebox.
Seal any fresh air vents and/or ash clean-out doors
located on the floor or wall of the fireplace. If left
unsealed, drafting may cause pilot outage or sooting.
Use a heat resistant sealant. 


Milli-volt controlled gas logs may be installed as a vented
decorative log set in compliance with ANSI Z21.60 and
National Fuel Gas Code, Section 6.6. 

      


Turn off gas supply to fireplace or firebox.
Have the fireplace floor and chimney professionally
cleaned to remove ashes, soot, creosote or other
obstructions. Have this cleaning performed annually
after installation.
Seal any fresh air vents or ash clean-out doors located
on floor or wall of fireplace. If not, drafting may cause
pilot outage or sooting. Use a heat-resistant sealant.
Do not seal chimney flue damper.
     



       





Exception: 
          



FP2370
damper
Damper Stop
Damper
FP2370
Figure 11 -
Damper Stop Installation
(Refer to WARNING at top of page)

A damper stop must be provided with the unit when used
for vented applications. Contact your dealer to obtain one.
The damper stop must be installed as shown in 
to prevent full closure of the fireplace damper blade and
provide a minimum 29 square inch flue opening.
 for installations in the Commonwealth
of Massachusetts.