NBST27 Unvented Gas Log Set
1. Center the gas log unit in the fireplace or firebox. Make certain the front feet of the grate
sit inside the front edge of the fireplace or firebox.
2. Anchor holes are located on the right and left sides of the unit. After centering the grate
correctly, mark the hole locations on the fireplace/firebox floor. Drill two (2) 5/32” diam-
eter holes approximately 1Z\x” deep.
3. Anchor the unit to the fireplace/firebox floor using the
screws provided.
For right corner installations, the piezo ignitor
can be moved to the opposite corner of the ap-
pliance:
1. Remove wire from back of ignitor.
2. Remove two (2) screws holding piezo brack-
et.
3. Reattach bracket on the opposite corner
(where inlet fuel comes into the valve) by us-
ing two clearance holes on burner base.
4. Reattach wire to ignitor.
FP2375
secure burner
FP2375
Figure 12 -
Secure Burner
Piezo Ignitor
(Original Location)