NBST27 Unvented Gas Log Set



Check your packing list to verify that all listed parts have
been received. You should have the following:
Unvented Gas Log Burner Assembly
Crushed Volcanic Rock, 3 bags
Anchoring Screws, 2
Ceramic Fiber Logs
Rock wool
Flickering Bright Embers, 1 bag
On/Off Log Switch Assembly
Installation/Operating Instructions
The following options may be used with the milli-volt con-
trolled heater. These options are not packaged with the
log set.
Hand Held Remote with Receiver
Wall Thermostat with 15' Wire
Wall Switch with 15' Wire
Hand held Thermostat Remote with Receiver
Andirons
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance. 




You should have the following items available before pro-
ceeding with installation:
External regulator (for propane/LPG and 1/2 lb.
natural gas systems only)
Piping which complies with local codes
Sediment trap (recommended)
Screwdriver
Tee joint.
Pipe sealant approved for use with propane/LPG
(Resistant to sulfur compounds)
Drill with 5/32 masonry bit
Pipe wrench or appropriate size crescent wrench
set
Manual shutoff valve






Natural *Propane (LP)
Inlet Minimum 5.0” w.c. 11.0” w.c.
Inlet Maximum 10.5” w.c. 13.0” w.c.
Regulator Pressure 3.5” w.c. 10.0” w.c.
Pilot Regulator 3.5” w.c. --
 An external regulator is required to reduce supply pres-
sure to a maximum of 13” w.c.



    
NBST27NV Nat. Millivolt 39,000 26,000
NBST27PV LP Millivolt 39,000 30,000

Piezo ignitor allows ignition of the pilot without the use of
matches or batteries.

 - All gas to the gas logs is shut off at the valve.
 - Valve position to light/maintain a standing pilot.
 - Valve position to turn ON/OFF log set with
remote switch/thermostat.
 - Variable position to control flame height
(heat output).

The gas log heater is fitted with a specially designed
safety pilot (ODS assembly) which senses the amount of
oxygen available in the room and shuts the gas log heater
off if the oxygen level begins to drop below a satisfactory
level. The pilot can only be relit when adequate fresh air
is available.

The millivolt gas log pilot is fitted with a milli-volt (thermo-
pile) generator to provide power for remote activation.