2 Full Bricks
(Be sure to install two (2) full
bricks in baffle as shown)
Baffle Assembly
ST1034
     
1. Firebrick Lt 9” x 4M\zn” x 1Z\v” (229 x 113 x 32 mm) S16040 11 12 15
2. Firebrick Angle Cut S16042 2 2 --
3. Firebrick Lt 7Z\v” x 4M\zn” x 1Z\v” (184 x 113 x 32 mm) S16043 4 4 --
4. Firebrick Lt 4Z\x” x 4M\zn” x 1Z\v” (114 x 113 x 32 mm) S16046 1 1 1
5. Firebrick Lt 2C\v” x 4M\zn” x 1Z\v” (70 x 113 x 32 mm) S16224 -- 1 --
6. Brick for Ash Drawer S16214 1 1 1
7. Firebrick Lt 7C\v” x 4M\zn” x 1Z\v” (197 x 113 x 32 mm) S16222 -- -- 4
8. Firebrick Lt 9” x 2Z\x” x 1Z\v” (229 x 64 x 32 mm) S16216 -- -- 1
Figure 3
Fire Brick Installation


An appliance mounted on a concrete floor does not
require floor protection.
Carpeting and any other combustible material shall not
cover Floor Protector.
If a combustible surface is applied to the concrete floor,
a clearance must be maintained equivalent to the area
reserved for the floor protector. (Fig. 4)

If the appliance is to be installed on a combustible floor
or a combustible floor covering, it must be installed on
a 3/8” (10 mm) thick noncombustible millboard floor
protector or durable equivalent. The pad must be in-
stalled beneath the appliance extending 18” (457 mm) in
Canada, 16” (406 mm) in the U.S. On any side equipped
with a door, and 8” (203 mm) on all other sides. In the
US, the pad must cover any horizontal chimney connec-
tor runs and extend 2” (51 mm) beyond each side.
A grouted ceramic floor-tile surface installed per local
building code considered equivalent.



