Product Manual

Mi-T-M
®
Electric Air Compressor Manual 15
PRE-START CHECKLIST:
1. Check oil level, add if necessary.
2. Remove any moisture in the air compressor air tank. NEVER attempt to
open the Air Tank Drain Valve when more than 10 PSI of air pressure is
in the air tank! Remove excessive pressure with an air tool, then open the
air tank drain valve in the bottom of the air tank. Close tightly when drained.
3. Make sure the pressure switch is in the "OFF" position.
4. Make sure the safety relief valve is working correctly.
5. Make sure all guards and covers are in place and securely mounted.
6. Fit the wheels and rubber tab on the tanks on which they are not already tted,
observing the illustration in below.
START-UP:
1. Read safety warnings before performing operation.
2. Ensure the pressure switch lever is in the "OFF" position.
3. Plug the power cord into a grounded outlet.
4. Move the lever on the pressure switch box to the "ON" position. This will allow
the air compressor to start building up pressure in the air tanks. When pres-
sure drops with usage, the air compressor will start automatically.
5. Set pressure by adjusting the pressure regulator knob counterclockwise for
less pressure and clockwise for more pressure.
6. If you notice any unusual noise or vibration, stop the air compressor and refer
to "Troubleshooting".
SHUTDOWN:
1. To stop the air compressor, move the lever on the pressure switch box to
the "OFF" position. Never stop the air compressor by unplugging it from the
power source. This could result in risk of electrocution or damage to unit.
2. Drain air from the air tanks by releasing air with an attached air tool or by
pulling on the safety relief valve test ring.
3. Once the air tank pressure gauge registers under 10 pounds, open the air
tank drain valve under each air tank to drain any moisture.
4. Allow the air compressor to cool down.
5. Wipe the air compressor clean and store in a safe, non-freezing area with the
cord coiled up and protected from accidental damage.
WARNING
RISK OF BODILY INJURY!
Never attempt to open the air tank
drain valve when more than 10
PSI is in the air tank!
OPERATING INSTRUCTIONS
WARNING
RISK OF BODILY INJURY!
Never assume the air com-
pressor is safe to work on just
because it is not operating. It
could restart at any time!
6-15R 6-15R
L15-30R L15-30P
5-20P5-20R
GROUNDED
OUTLET BOX
GROUNDED
OUTLET
6-50P6-50R
W
W
G
G
G
G
G
G
Z
Z
Y
Y
G
G
X
X
125V
20A
(5-20)
250V
15A
(6-15)
250V
50A
(5-20)
3 250V
30A
(15-30
)
(B)
(A)
(D)
(C)(E)
GROUNDING
PIN
EXAMPLES OF POSSIBLE CORD PLUGS AND CORRESPONDING RECEPTACLE