Instruction manual

11
1. Reversing Edge device (must be normally open contact):
Note: If the door is controlled by any device or wired in such a manner that the door is not controlled by constant
pressure on close then an appropriate reversing edge must be installed.
2. External interlock: Remove jumper between terminals 1 and 2 and wire interlock between these two
terminals.
3. Radio control receiver: Wire standard radio receiver to separate radio strip on side of control box or to terminals 7, 8
and 9 on control terminal strip inside control box.
4. Single button open/close device: Wire to terminals 7 and 8 on control terminal strip.
5. Loop detectors, standard photocells (with a N.O. contact) and other reversing devices: Wire to terminals 3 and 6
on control terminal strip. IMPORTANT: PHOTOCELLS MUST BE MOUNTED NO HIGHER THAN 6” OFF THE FLOOR.
6. 24 Volt power: Wire to terminals 1 and 9 on control terminal strip
CONNECTION OF A REVERSING EDGE DEVICE AND CONTROL ACCESSORIES