Bluetooth Operation Manual for EasyStartTM Soft-Starters
EasyStart Bluetooth Diagnostic Manual Table Of Contents WARNING ..................................................................................................................................................... 2 Introduction .................................................................................................................................................. 2 Is my EasyStart a Bluetooth Model? ..................................................................................................
EasyStart Bluetooth Diagnostic Manual WARNING Bluetooth operation with EasyStart is designed to provide diagnostic feedback when troubleshooting an A/C system. It should be used only by qualified HVAC technicians and HVAC engineers with a good understanding of the system. Changing fault detection, limits, and values in the Bluetooth application for EasyStart can damage the connected compressor or EasyStart under some circumstances.
EasyStart Bluetooth Diagnostic Manual Connecting to EasyStart A smart device with the EasyStart app downloaded to it is required to use EasyStart’s Bluetooth interface. EasyStart itself must be powered to establish a connection. Typically, this is when a cooling or heating cycle is called for by the thermostat. Note: Some A/C systems will shut down if a fault occurs and remove power.
EasyStart Bluetooth Diagnostic Manual A successful connection is shown in Figure 2. “Connected” is shown in the status box with a green circle and the other tabs along the bottom become available. If you used the scanning feature, the Bluetooth ID field will be updated with the full unique Bluetooth ID for the EasyStart it is connected to. Future connections can use this ID instead of scanning. The ID should be noted and used if more than one local EasyStart can be powered at one time.
EasyStart Bluetooth Diagnostic Manual Status Tab Once connected, tap the status tab along the bottom to switch to the Status & Live Data page, shown in Figure 3. This page will show the current state of EasyStart and some basic diagnostic information. Status This shows the current status of the EasyStart. These mirror the LED code shown on the EasyStart circuit board. Visit our EasyStart Knowledge Bank for the latest information on what these statuses mean, as well as troubleshooting steps to take.
EasyStart Bluetooth Diagnostic Manual Re-learn Tab Once connected, tap the Re-learn tab along the bottom to switch to the Re-learn / Power-Up page, shown in Figure 4. This page allows for modifying EasyStart behavior for certain situations that call for it. Tap “Refresh Data from EasyStart” at the top to get the latest settings stored in the connected EasyStart. If you make a change, tap “Send Settings to EasyStart” at the bottom to save the new settings to the connected EasyStart.
EasyStart Bluetooth Diagnostic Manual Diagnose Tab Once connected, tap the Diagnose tab along the bottom to switch to the Diagnose and Upload page, shown in Figure 5. Using this page will upload data from memory inside EasyStart to Micro-Air for evaluation. An internet connection on the smart device is required for this feature. The upload should be followed up with a report using the Micro-Air Contact Us Page on our website if you are not already working with a Micro-Air service technician.
EasyStart Bluetooth Diagnostic Manual Update Tab Once connected, tap the Update tab along the bottom to switch to the Firmware Update page, shown in Figure 7. This page is used to get any updates that may become available over time. Tap the “Check for Updates” button at the top and follow the prompts to see if your EasyStart is the latest revision or to update EasyStart. EasyStart is a mature product so there will not be many updates.
EasyStart Bluetooth Diagnostic Manual Re-Learn (Factory Reset) Procedure EasyStart is ready to learn out of the box and is completed on the first 5 successful cycles after installation. The learned data is then locked in for the life of EasyStart. Typically, there is no reason to re-learn (factory reset) this data, however some circumstances will call for it. This section provides step-by-step instructions on how to perform a re-learn on your EasyStart.
EasyStart Bluetooth Diagnostic Manual Setting No Power Up Delay EasyStart delays the start for several reasons, including faults and pressure equalization. However, some applications need to have the compressor immediately start so EasyStart can be integrated into the system. These systems must manage the start and fault delays if the EasyStart delays are disabled. This section provides step-by-step instructions for bypassing the EasyStart start delays.
EasyStart Bluetooth Diagnostic Manual Appendix A: Additional Resources This document references various other Micro-Air resources and are listed here. EasyStart Knowledge Bank Where all EasyStart resources are saved, including FAQs, articles, procedures, and troubleshooting guides. http://www.micro-air.com/kb_easystart.cfm EasyStart Generic Home Installation Guide A guide for installing in any home system with notes on adapting to a compressor monitoring system. http://www.micro-air.