AUTOMATED FACTORY-SELF TEST PROGRAM
Self-Test Mode
The FX-1 software contains a self-test program to facilitate factory testing of the entire air-
conditioning system. Once the self-test mode is activated, the test cycle will continue until the AC
power is interrupted or the on/off button is pressed once which returns the system to the off mode.
Activate the self-test by pressing and holding the on/off button while turning on the AC power. Be
sure to continue to hold the button until the power on reset is completed… FX-1 is now in the self-
test mode.
Once activated the self-test software will continuously execute the following procedure:
1 - Turn on in the heat mode and supply heating for ten (10) minutes.
2 - Stop heating and run the fan only for five (5) minutes.
3 - Switch to cooling and continue cooling for ten (10) minutes.
4 - Stop cooling and run the fan only for five (5) minutes.
5 - Return to step one (1) and continue until interrupted.
The test mode will continue until the power is interrupted or the test is halted by pressing the on/
off button once.
SPECIFICATIONS
SET POINT OPERATING RANGE ........................................................................................... 55 ° F TO 85 ° F
AMBIENT TEMPERATURE OPERATING RANGE DISPLAYED ..................................................... 55 ° F TO 85 ° F
SENSOR ACCURACY ........................................................................................................... ± 2 °F AT 77 ° F
LOW VOLTAGE LIMIT 115 VOLT UNITS ...........................................................................................75 VAC
LOW VOLTAGE LIMIT 220 VOLT UNITS .........................................................................................175 VAC
LOW VOLTAGE PROCESSOR RESET ................................................................................................. 60 VAC
LINE VOLTAGE .....................................................................................................115 THROUGH 250 VAC
FREQUENCY ............................................................................................................................ 50 OR 60 HZ
FAN OUTPUT .............................................................................................................6 AMPS @ 115 VAC
FAN OUTPUT .............................................................................................................6 AMPS @ 230 VAC
VALVE OR HEATER OUTPUT...................................................................................... 1/4 AMP @ 115 VAC
VALVE OR HEATER OUTPUT...................................................................................... 1/4 AMP @ 230 VAC
PUMP OUTPUT ........................................................................................................... 1/4 HP @ 115 VAC
PUMP OUTPUT ........................................................................................................... 1/2 HP @ 230 VAC
COMPRESSOR OUTPUT ................................................................................................... 1 HP @ 115 VAC
COMPRESSOR OUTPUT ................................................................................................... 2 HP @ 230 VAC
MINIMUM OPERATING TEMPERATURE ...................................................................................................0 ° F
MAXIMUM AMBIENT OPERATING TEMPERATURE ................................................................................180 ° F
MAXIMUM RH CONDITIONS ..................................................................................... 99% NON CONDENSING
POWER CONSUMPTION ................................................................................................. LESS THAN 5 WATTS