System Description Windows CE Image Version 2.22.
Imprint Windows CE Manufacturer Micro Innovation AG Spinnereistrasse 8-14 CH-9008 St. Gallen Switzerland Tel. +41 (0)71 243 24 24 Fax +41 (0)71 243 24 90 info@microinnovation.com http://www.microinnovation.com Original language German Editor Beat Gähler Brand and product names All brand and product names are trademarks or registered trademarks of the owner concerned. Copyright © Micro Innovation AG, CH-9008 St. Gallen All rights reserved, also for the translation.
Windows CE Contents Contents 1 General .................................................................................................................6 1.1 Startup behavior .........................................................................................................6 1.1.1 XV400 .............................................................................................................................6 1.1.2 XV100 ............................................................................
Contents 4.7.2 4.7.3 4.7.4 4.7.5 Windows CE DNS.............................................................................................................................. 30 WINS............................................................................................................................ 30 Info ............................................................................................................................... 31 Command line parameters ........................................
Windows CE Contents 7.7.3 HTTP Authentication.....................................................................................................60 7.7.4 Sample Settings............................................................................................................61 7.7.5 WEB Server Start/Stop .................................................................................................62 7.8 File server ....................................................................................
General Windows CE 1 GENERAL The operating system is implemented in English on all MICRO PANEL devices with Windows CE®. Note: This documentation applies to MICRO PANEL devices which have the Windows® CE 3.0 operating system from image version 2.20.0 and Windows® CE 5.0 from image version 2.22.0. 1.1 1.1.1 STARTUP BEHAVIOR XV400 With all MICRO PANEL devices from image version 2.00 (see also System properties), the operating system is started from a PCMCIA or CompactFlash card.
Windows CE 1.1.2 General XV100 With all XV100 MICRO PANEL devices from image version 2.22 (see also System properties), the operating system is started from an internal memory or SD Flash card. The operating system is stored in the OS directory. If the startup is from the internal memory, the operating system is started from a linear memory area. If a different operating system in the internal memory was loaded into the OS directory, a copy of this OS is copied to the linear memory area.
General Windows CE After Windows CE is launched, the following functions are run if the CTRL/DOWNLOAD button is not pressed: 1. The bootloader searches for the AutoLaunch.inf file on the SD Flash card. If this file is present, the program is started under [AutoLaunchBoot]. See also chapter AutoLaunch. 2. The registry entries are transferred when the AUTOEXEC.REG file is found in the root directory of the boot device. See also chapter Autoexec.reg. 3. The bootloader also looks for the AUTOEXEC.
Windows CE General Example of an «Autoexec.bat» file: ECHO OFF REM ************************************************ REM Verify boot device, if parameter is not REM available, the boot device is StorageCard SET bootdev=StorageCard IF "%1"=="" GOTO START SET bootdev=%1 REM ************************************************ :START REM START Shortcut –p GRSW3.EXE START CeRemoteSvr.exe -h START GRSW3.EXE ECHO ON This example initially checks whether the pass parameter (%1) is set for the boot device.
General Windows CE The following MSDOS compatible commands are available: ATTRIB Shows file attributes or changes them. CALL Calls a batch program from another one. CD, CHDIR Changes the current directory or shows its name. CLS Clears the screen content. COPY Copies one or several files to another position. DATE Changes the set date or displays it. DEL Deletes one or several files. DIR Lists the files and subdirectories of a directory.
Windows CE 1.5 1.5.1 General CTRL/DOWNLOAD BUTTON XV400 The CONTROL button on the device has two different functions: 1. If the button is pressed on startup, the bootloader will list all directories and files on the Compact Flash card. This can be useful when analyzing problems. Windows CE is then started in the usual manner. 2. If the button is held down during the Windows CE startup (after the bootloader), the Autoexec.bat and Autoexec.reg files are not run.
General Windows CE The file system on the device essentially contains the following important directories: InternalStorage StorageCard StorageCard2 Windows Content of the internal memory Content of the PCMCIA, Compact Flash or SD Flash card Content of the second PCMCIA or Compact Flash or SD Flash card, if present Directory with the system files Note: All directories apart from «InternalStorage», «StorageCard» and «StorageCard2» are located in the working memory (RAM) and are re-created with every devic
Windows CE 1.7 General SHORTCUTS Shortcuts can be created on the Desktop for easier operation. As the MICRO PANEL does not have a persistent registry, (i.e. the registry is set according to the CE Kernel with every start), the shortcuts must be restored with every start. See also chapter Startup behavior. Shortcut or link files can be created with the SHORTCUT program. The program can be called in the AUTOEXEC.BAT file -- see also chapter Autoexec.bat.
General 1.8 Windows CE POWER SUPPLY INTERRUPTION In the event of a power supply failure, the NVSRAM (non-volatile SRAM) ensures that the data is saved. If the following dialog appears when the device is started, this means that the data in the NVSRAM could no longer be saved. This either indicates a hardware fault or the fact that a serious fault has occurred in Windows CE, which prevented saving. If this message is present, please contact your MICRO PANEL distributor.
Windows CE Ethernet 2 ETHERNET The Ethernet interface is implemented in compliance with the IEEE 802.3 (10/100BASE-T) standard. The network is implemented with shielded twisted-pair cables and shielded RJ45 plugs. The devices networked with the MICRO PANEL must also be provided with shielded connections. The twisted-pair cable selected for use in Ethernet networks must comply with the cable specifications with regard to cable length and transmission speed. See also specification to EIA/TIA 568 TSB-36.
Ethernet 2.1.1 Windows CE NAME RESOLUTION IN WINDOWS NETWORKS The name resolution is absolutely necessary in order to access enabled resources (drives, directories, printers) of a computer with the Windows operating system. Access via IP addresses is not supported by Windows CE. The name resolution under Windows CE is executed via the NetBios name (UDP, Port 137) service.
Windows CE • Ethernet The net use command connects or disconnects the MICRO PANEL with an enabled resource. The connection of resources is not absolutely necessary, but is nevertheless recommended. This has the advantage that access from the application is always the same, irrespective of the computer, directory or printer name.
Printing Windows CE 3 PRINTING Different interfaces are provided for use as a printer terminal. These are the Ethernet interface, the parallel interface and the serial interface. Windows CE currently contains the following printer drivers: Printer types *: PCL Deskjet PCL Laser HP Laserjet HP Color Laserjet HP Business Inkjet HP Deskjet 9xx HP Deskjet 61xx HP Photosmart 7xxx HP Photosmart 1xx Printer driver pcl.dll emprint.dll * These are printer names which are used for printer selection. 3.
Windows CE 3.2 Printing PARALLEL INTERFACE Some MICRO PANEL devices are provided with a parallel printer interface which can be used for connecting the printer. Note: Only printers that support the PCL protocol can currently be connected. PCL is a language developed by HP® which, however, is also supported by other printer manufacturers. 3.3 SERIAL INTERFACE The serial port can also be used for connecting the printer. Two different modes are always available for printing via the serial port.
System settings Windows CE 4 SYSTEM SETTINGS All adjustable system settings can be accessed under «Start» Î «Programs» Î «Control Panel». If the application is started with the command line parameter –fullscreen, the full screen resolution is used, i.e. the taskbar is not visible. See also chapter Command line parameters.
Windows CE 4.1 4.1.1 System settings COMMAND LINE PARAMETERS XV400 The command line call of the programs with the suffix .CPL is as follows: Parameter -fullscreen -cpl «CPL program» Other parameters Examples: Set number of colors to 16 bits Rotate screen orientation 90° Set backlight to 60% Description The program uses the full screen, i.e. the taskbar is not visible. This function is only active if the parameter –cpl is not used. Selection of the .
System settings 4.3 Windows CE DATE / TIME AND TIME ZONE SETTING (DATETIME) 4.3.1 DATE/TIME Month/Year Hours Minutes Seconds Day You can change the month and year using the two buttons stated (<< and >>). You can select the day directly by touching the day of the month. Hours, minutes and seconds are changed after they are selected with the buttons shown above. Hours must be entered in 24 hour format.
Windows CE 4.3.3 System settings COMMAND LINE PARAMETERS The command line call is described in chapter 4.1. The following parameters are supported: Parameter Description Set time zone according to the Time Zone ID, e.g. -id 6912 -id [Time Zone ID] The Date/Time dialog of the Time Zone tab shows the time zone IDE of the selected time zone. 4.4 4.4.1 SCREEN SETTING (DISPLAY) BACKLIGHT This program can be used to set the backlight to the required value. The setting made is stored as persistent data, i.e.
System settings 4.4.3 Windows CE ORIENTATION Display orientation can be set with the «0» (default setting) or «90» settings. The display is rotated in a clockwise direction. The «90» setting should be selected for vertical mounting. The picture on the left of the dialog shows the orientation set. The setting is not transferred until after a restart. Note: This function is not supported by all MICRO PANEL devices. 4.4.4 COLORS This setting enables the number of screen colors to be selected.
Windows CE Parameter -back [% value] -dim [% value] -rotate 0 -rotate 90 -colors 8 -colors 16 -shell show -shell hide -r M000174-19 System settings Description Set backlight, e.g. -back 60 The supported percentage values depend on the device concerned. The entered percentage value is rounded up to the next higher value supported. Sets the reduction value of the backlight used by the screen saver, e.g. –dim 60. The supported percentage values depend on the device concerned.
System settings 4.5 Windows CE SOFTWARE INPUT PANEL A range of different software keyboards are provided for entering characters on the device. The «Input Panel active» setting can be used to activate or deactivate the software keyboard. The option is deactivated by default. A change of this setting requires the system to be restarted. When the software keyboard is activated, the icon with the sheet and the red pen are contained in the taskbar (see figure at top right).
Windows CE 4.5.3 System settings CHANGE THE BUTTON SIZE ON THE KEYBOARD: The size of the buttons is set with the settings of KeyButtonsSize57 or KeyButtonSize. The maximum size depends on the display size. With small displays, the value should not be too big as the input window may be overlaid with the keyboard. The smallest value for the buttons should not be less than 0x16. Smaller settings make the letters illegible.
System settings 4.6 Windows CE LICENSE ADMINISTRATOR (LICENSE) The license administrator is used for increasing the number of license points on the device. Serial Shows the serial number of the device that is printed on the device nameplate. Points This field contains the current number of installed license points for the device. Change License Touching this button will activate a keypad with which the activation code can be entered manually. See also the chapter Relicensing Procedure.
Windows CE 4.7 System settings NETWORK SETTING (NETWORK) Note: Modifications to the network settings of XV400 devices are not activated until the device is restarted (see also documentation «Network in brief»). A restart is not necessary for XV100 devices. 4.7.1 IP ADDRESS It is always possible for the device to obtain an IP address (network address) via a DHCP server on startup «Obtain an IP address via DHCP». However, for the device to have a unique ID, you should select «Specify an IP address».
System settings Windows CE IP classes The private IP address ranges of classes A, B and C are listed in the following table. Private IP address ranges Standard subnet mask Class A network 10.0.0.0 to 10.255.255.255 255.0.0.0 Class B network 172.16.0.0 to 172.31.255.255 255.255.0.0 Class C network 192.168.0.0 to 192.168.255.255 255.255.255.0 Note: All of the above listed address ranges (compliant with RFC 1918) are not available on the Internet, i.e. they are reserved for private use.
Windows CE 4.7.4 System settings INFO The MAC address of the HMI device is displayed in the Info page. This is a manufacturer-specific and unique Ethernet connection number of the device. Note: The Info tab is not available for XV100 devices. The MAC address can be viewed by double touching the icon in the network connection in the taskbar. 4.7.5 COMMAND LINE PARAMETERS The network settings can either be made using the «IpSetup.exe» program or as described in the chapter Command line call.
System settings 4.8 Windows CE OWNER (OWNER) This program is used for specifying the user, password and domain for logging into an external Windows® server/PC. The default setting is the user name MI_PANEL and no password. Specific operations must be carried out in order for the selected settings to be retained after a restart. If the entries are acknowledged with OK, the current settings can be saved inside the registry file \NETWORK.REG. The content of the REG file must be inserted in the Autoexec.
Windows CE System settings 4.10 SYSTEM PROPERTIES (SYSTEM) 4.10.1 GENERAL The «General» tab contains important information about the device and the installed Windows CE version. «Image Release» shows the version of the CE Image. See also the chapter Licensing. 4.10.2 MEMORY The «Memory» tab contains information on the available «RAM» working memory. Total Memory: Contains the total memory size minus the memory reserved for the Windows CE Image (i.e. CE Kernel).
System settings Windows CE 4.10.3 MISC The «Misc» tab displays the current temperature on the device and the operating hours. Details displays the total operating hours run, broken down into individual temperature ranges: Note: This function is not supported by devices. The total operating hours histogram are only supported from 2.14.0 (see System properties). The therefore only counted from 2.14.0. all MICRO PANEL or the temperature OS Image Release operating hours are 4.10.
Windows CE System settings 4.11 TOUCH (TOUCH) This program is used for the Touch calibration and for the Touch Enable/Disable. If the program is started without command line parameters, the following dialog appears: 4.11.1 TOUCH ENABLE/DISABLE The touch display always distinguishes between «normal status», «touch disabled» and «touch locked» status. When disabled or locked the device cannot be operated.
System settings Windows CE Touch Disable/Enable Touch Lock ECHO ON Touch.exe –disable ….other command lines!!! Touch.exe –enable ECHO OFF ECHO ON Touch.exe –lock ….other command lines!!! ECHO OFF 4.11.2 TOUCH CALIBRATION Note: Touch calibration is only required for resistive touch devices. Touch calibration only needs to be carried out if a MICRO PANEL with a resistive touch is no longer reacting correctly to screen touch operations. If the program is started with «Touch.
Windows CE System settings 4.12 KEYBOARD SETUP (KEYBOARD) The keyboard setup – control panel makes the country setting for a USB keyboard. You can select the desired keyboard layout in the dialog shown above. The selected keyboard layout is still retained after a restart. The following keyboards are supported: • English (United Kingdom) • English (United States) • French (France) • German (Germany) • German (Switzerland) • Italian (Italy) • Spanish (Spain) 4.12.
System settings Windows CE 4.13 BOOTDEVICE SETUP (BOOTDEVICE) Note: The BootDevice setup is only available on XV100 devices. BootDevice Setup is used to specify the medium from which the panel is to start. The relevant selection options are displayed according to the features of the panel. 4.13.
Windows CE System settings 4.14 STORAGEMANAGER (STORAGEMANAGER) Note: The incorrect handling of this program may cause panels to become non-operational. It should therefore only be used by experienced users. The StorageManager should only be used in exceptional situations. Note: The StorageManager is only available on XV100 devices. 4.14.
System settings Windows CE 4.14.3 RECOMMENDED SETTINGS FOR INTERNAL MEMORY 4.14.
Windows CE Network test 5 NETWORK TEST Once you have adjusted the system settings, particularly network settings, first of all check whether the device can be addressed in the network. For this connect the device directly to a network connection/hub (patch cable) or directly with a network cable to your workstation (cross cable). From the workstation carry out at the MS-DOS entry prompt the «Ping» command with the IP address set on the device (see example).
ActiveSync connection Windows CE 6 ACTIVESYNC CONNECTION An ActiveSync connection can be used for data transmissions, diagnostics or debugging. An exclusively DEBUG connection can also be created via «Manual Server» (see also Procedure: Manual Server). The ActiveSync connection requires the installation of the Microsoft ActiveSync program on the PC and the starting of the «Repllogswitch» program on the device. This connection can be implemented via the serial or USB interfaces.
Windows CE 6.2 ActiveSync connection PROCEDURE: ACTIVESYNC • The Microsoft ActiveSync must be started on the PC. • The «RepllogSwitch.exe» program must be started on the MICRO PANEL («Start – Programs – Communication – RepllogSwitch») • Connect the panel and the PC via USB or the serial interface. • Select the required interface in the dialog shown above. • The following dialog will then appear.
ActiveSync connection Windows CE **Note: The partnership prompt will not appear if the following setting is made in the PC's registry: [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows CE Services] "GuestOnly"=dword:00000001 Æ For example, the file system on the device can now be viewed using the «Browse» function. 6.3 PROCEDURE: MANUAL SERVER The connection using «Manual Server» is designed for DEBUG tasks only.
Windows CE Programs 7 PROGRAMS MICRO PANEL devices with Windows CE contain a number of programs which are described briefly below. This list is not complete and the programs are not available on all MICRO PANEL devices. 7.1 PING The «Ping» program for the network test can be started in the following way via the menu. The following dialog appears if the program is started without command line parameters: The dialog can be used to set the IP address and the number of pings.
Programs 7.2 Windows CE FORMAT Note: The «Format» program is only available on XV400 devices. The «Format» program for formatting Flash cards (PCMCIA or Compact Flash) can be started via the menu shown below. The program is started as follows: The Flash card drive can be selected in the top left selection field. The lower display field shows the information about the selected drive. This information includes details such as FAT type, total memory, currently used memory etc.
Windows CE 7.3 Programs REMOTE SERVER The Remote Server/Client programs allow the device to be operated remotely. A MICRO PANEL with Windows CE can thus be operated from a PC (see Remote client). The server program for Windows CE is called «CERemoteSvr.exe» and provides the services in a PC or another MICRO PANEL. For the password protection see Password settings.
Programs 7.3.1 Windows CE COMMAND LINE PARAMETERS Parameter Description -port n Set port number to n, values between 1000 and 65535 are permissible (the default port number is set to 51738). -c Closes an «open» connection between server and client. The call only has a function if the call is executed on the device on which the server is already running. -exit Exits the remote server. This call only has a function if the remote server is already running.
Windows CE 7.4 Programs REMOTE CLIENT The remote server/client programs enable the target devices to be remotely controlled. For example, a panel with Windows CE can be operated from a PC. The following client programs are available: CERemoteClient.exe RemoteClient.exe Remote client for Windows CE Remote client for Windows NT, 2000, XP See also chapter Remote server. The IP address of the server must be stated in the entry field. An additional port number can be added if required (e.g. «192.168.1.
Programs 7.4.2 Windows CE SYSTEM MENU The System menu contains the following entries, although not all entries are available in Windows CE: ** Menu item Request screen refresh Touch lock Touch unlock Touch disable Touch enable Description: This function refreshes the view in the remote client. Send Ctrl-Alt-Del Send Ctrl-Esc Send Alt-Tab Ctrl Down Ctrl Up Alt Down Alt Up These functions execute the corresponding button combination on the device.
Windows CE 7.5 Programs FTP SERVER The FTP server (File Transfer Protocol) is used for transferring files via the Ethernet. The server program for Windows CE is called «FtpSvr.exe». The following dialog appears on startup. The Hide function is used to minimize the dialog, i.e. it is reduced to the icon inside the start bar. Double touching this icon will then cause the above dialog to be displayed again. A password protection can be activated via Password Settings (see Password settings).
Programs 7.5.1 Windows CE PASSWORD SETTINGS The password settings are stored in the «FtpSvr.ini» file in the directory «\“Bootdevice”\OS\». The data stored is naturally encrypted. The file is stored on the boot device, which means that the password settings are also retained after a restart. 7.5.2 COMMAND LINE PARAMETERS The following parameters are supported: Parameter Description -d Deactivates a previously activated password protection.
Windows CE 7.6 Programs HTML BROWSER (INTERNET EXPLORER) The program can be called via command lines and also via the Start menu. The program file for the command line call is called «MiExplorer.exe». If the program is called via the Start menu (Start – Programs – Internet Explorer), the settings are transferred from the INI file in the directory «\StorageCard\OS». If the program is started with MIExplorer.exe without any parameters, the «Back», «Forward», «Refresh» and «Exit» buttons are visible.
Programs 7.6.1 Windows CE COMMAND LINE PARAMETERS The program can be called via command lines and also via the Start menu. The startup behavior and the display of the browser can be modified either via an INI File or command line parameters. The following command line parameters are supported: Parameter Description -a «Start page» Specifies a start page such as http://www.microinnovation.
Windows CE 7.6.2 Programs INI FILE The startup behavior and the display of Internet Explorer can be modified either via the command line parameters (see chapter Command line parameters) or INI File. The directory «\Storagecard\os» contains an example of an INI file «MiExplorer.ini». The INI file contains the following settings.
Programs [MiExplorer Buttons] LargeIcons GoBack GoForward Stop Refresh GoHome GoSearch Open Print Taskswitch Close 56 Windows CE Defines which buttons to be shown in the toolbar! =0: Display buttons at standard size =1: Display buttons extra large (default) =0: Back button not visible =1: Back button is displayed (default) =1: Forward button is displayed =1: Stop button is displayed (default = 0) =1: «Refresh» button is displayed (default =1) =1: «GoHome» button is displayed (default =0) Æ see also [
Windows CE Programs Example of an INI file: [MIExplorer] Start Page=http://www.microinnovation.com Search Page=http://www.google.ch CacheLimit=0 FullScreen=0 StatusBar=0 ToolBar=1 MenuBar=0 AddressBar=0 AddressBarWidth=150 Animate=0 TaskSwitch EXE= [ProxySettings] ProxyEnable=0 ProxyServer=itgproxy:80 AnchorUnderline=no [MIExplorer Buttons] LargeIcons=1 GoBack=1 GoForward=1 Stop=0 Refresh=0 GoHome=0 GoSearch=0 Open=0 Print=0 Find=0 Taskswitch=0 Options=0 Close=1 7.6.
Programs 7.7 Windows CE WEB SERVER (HTTPD) The device is provided with a web server that is based on the standard web server from Windows CE 3.0 and Windows CE 5.0 respectively. The web server (HTTPD) supports only a part of the HTTP/1.0 protocol with restricted functionality. ASP (Active Server Pages) is supported with JScript 3.0 and VBScript 3.0 (Windows CE 3.0) and JScript 5.6 and VBScript 5.6 (Windows CE 5.0) respectively.
Windows CE 7.7.2 Programs VIRTUAL DIRECTORY SETTINGS These registry entries contain the mapping between the virtual directories in the web server and the physical directories on the device. If required, the authentication level and the access permissions can be set for each directory.
Programs 7.7.3 Windows CE HTTP AUTHENTICATION Only NTLM authentication is supported. If no authentication is required, the «NTLM» value (see table above) must be set to 0 and all «A» registry entries also set to 0. If authentication is used, the registry entry «NTLM» must be set to 1. The «A» registry entries of the corresponding virtual directories must also be set to 1 (see chapter Virtual Directory Settings). Note: Only the local User Administration can be used (see chapter 7.
Windows CE Programs P Access Permissions The registry entry P describes the type of access permission granted for every virtual directory. If the registry entry is missing, the default access permissions are Read, Execute and Script (hex value 0205).
Programs 7.7.5 Windows CE WEB SERVER START/STOP The WEB server is not started by default. It must be ensured that the registry entries are set correctly before the web server is started. The web server can be started and stopped with the program HttpdStart.exe.
Windows CE 7.8 Programs FILE SERVER With Windows CE 5.0 a file server is contained in the device. Note: Further information on the functionality of the file server is provided in the Microsoft MSDN documentation. 7.8.1 GENERAL SETTINGS The following registry settings control the functionality of the file server (see also chapter Registry Editor). Note: Changes to the registry entries are not active until the next restart of the file server (see File server start/stop) of the file server.
Programs 7.8.3 Windows CE FILE SERVER START/STOP The file server is started by default. The file server must be restarted after registry entries are changed. The file server can be started and stopped with the program services.exe. The possible command line calls are listed in the table below: Functionality File server restart Start Stop Display status 7.8.4 Call Services.exe refresh SMB0: Services.exe start SMB0: Services.exe stop SMB0: Services.
Windows CE 7.9 Programs USER ADMINISTRATION (USERADMIN) The NTLM user administration is used for managing the users and associated passwords on the MICRO PANEL. This user administration is used by the WEB server and the File server. Note: The users are first only administered temporarily on the MICRO PANEL. Only with the command line parameter «permanent» are the currently set users permanently accepted. This means that the user definitions are also retained after a restart of the MICRO PANEL.
Programs Windows CE 7.10 SNTP CLIENT Under Windows CE 5.0 the device contains a Simple Network Time Protocol (SNTP) client. The SNTP implementation is derived from the Network Time Protocol (NTP). SNTP synchronizes the system time on a device with that of an SNTP server. This in turn receives its time from a reference source. Note: Further information on the functionality of the SNTP client is provided in the Microsoft MSDN documentation. 7.10.
Windows CE Programs 7.10.2 SAMPLE SETTINGS The settings for the SNTP client can be set as follows in a REG file (see also chapter Autoexec.reg): [HKEY_LOCAL_MACHINE\Services\TIMESVC] "server"=multi_sz:"swisstime.ethz.ch","thrad.cybernet.ch" "AutoUpdate"=dword:1 "ServerRole"=dword:0 "refresh"=dword:927C0 "recoveryrefresh"=dword:57E40 "threshold"=dword:5265C00 Notes on the above example: • The entries with «dword» are in hexadecimal format.
Programs Windows CE 7.11 REGISTRY EDITOR The registry editor in Windows CE is called «RegEdit.exe». The functions are comparable with those of the registry editor in Windows 98, NT or 2000. The following window appears when the startup is carried out without parameters (see also Command line call): The registry editor enables system settings to be displayed or edited. The buttons inside the toolbar have the following functions.
Windows CE Programs 7.11.1 COMMAND LINE CALL Parameter Description -import «file» Import the entries from the stated REG file -export «file» Export of the complete registry to the stated file « "File" » Import of the REG file, the file name must be placed between opening and closing delimiters! This entry is only supported to ensure compatibility, use the parameter «import». -q If the call is executed without the –q parameter, a message will appear on screen after the import.
Programs Windows CE 7.12 BACKGROUND PICTURE (WALLPAPER) Use this application to select a background picture for the desktop. Only the BITMAP (*.BMP) file format is supported. The command line call is as follows: wallpaper.exe –b «file name including the path» For example: wallpaper.exe –b \storagecard\wince.bmp Note: The setting is lost after a device is restarted. The call for the background picture must be inserted in the Autoexec.
Windows CE Programs 7.13.1 COMMAND LINE CALL The Command line call is described in chapter 4.1. All parameters can be used as required, although only the settings of the used parameters can be changed.
Programs Windows CE 7.14 AUTOLAUNCH Note:. The Tool AutoLaunch is only available on XV100 devices. The AutoLaunch.exe tool detects the insertion of an SD card and carries out one required action. It is started by the OS and cannot be closed. The \StorageCard\AutoLaunch.inf file is used to configure the tool. The following requirements must be observed for the file entries: • Only one entry is allowed per command. In case several are present, only the first one is used.
Windows CE Programs 7.15 DEVICE RESTART (REBOOT) The auxiliary program reboot.exe executes a device restart. When no command line parameter is entered, a confirmation prompt will appear that has to be acknowledged by the user before the device is restarted. If the call is executed as follows «reboot.exe –quiet», no confirmation prompt will appear. 7.16 INFORMATION DISPLAY (INFO) The auxiliary program info.exe displays the information of the system.
Programs Windows CE 7.18 SYSTEM PERFORMANCE (IDLECOUNT) The auxiliary program idlecount.exe records and displays system performance. The system performance is calculated and displayed as soon as the program is started. The following settings can be changed via the menu: Menu item Description Refresh Interval Set the refresh interval between 100 ms and 10 s, default is 500 ms. Style The curve can be displayed as a line or as a bar graph. Freeze Graph Stop or restart recording and display.
Windows CE Programs From Windows CE 5.0 Professional Plus 8 PROGRAMS FROM WINDOWS CE 5.0 PROFESSIONAL PLUS 8.1 8.1.1 FILE VIEWER APPLICATIONS FILE VIEWER APPLICATION LIMITATIONS The Microsoft file viewers do not provide all of the functionality that is available in their corresponding Windows desktop applications. Typically these limitations result in a different document layout or presentation; however, in some cases, document content may not be visible.
Programs From Windows CE 5.0 Professional Plus 8.1.2 Windows CE MICROSOFT PDF VIEWER The Microsoft PDF Viewer gives the user the possibility to show PDF documents on a Windows CE device. When creating the documents, the user should take the functional limitations into account. To generate a PDF document the Adobe Acrobat should be used. Generally the user must check whether the created PDF document is shown correctly.
Windows CE Licensing 9 LICENSING The MICRO PANEL devices are provided with an integrated licensing system. A certain number of licensing points are required depending on the functions used. Devices already come on delivery with a standard number of license points depending on type. The actual number of license points is shown during the startup and inside the system information display (see chapter Startup behavior, System properties and License Administrator).
Index Windows CE 10 INDEX Access authentication Access permissions ActiveSync ActiveX Alt down Alt up Autoexec.bat Autoexec.bmp Autoexec.
Windows CE Request screen refresh Saving Screen saver Screen settings Serial interface Shortcut Shortcuts SIP Software Input Panel Software keyboard Speed Start/Stop WEB server Startup behavior Startup bitmap StorageMemorySize Subnet mask System System performance System properties System settings Temperature M000174-19 Index 50 70 23 23 19 13 13 26 26 31 62 6 24 73 29, 30 33 74 33 20 34 Temperature histogram Time Time zone Touch Touch calibration Touch disable Touch enable Touch lock Touch unlock Touc
Notes Windows CE 11 NOTES 80 M000174-19
Windows CE M000174-19 Notes 81