MICRONIX PC/104 POWER SUPPLY PV-5120, 22 & 24 POWER SUPPLY MODULE WITH UPS AND UP TO 3.84 MB SSD FLASH PC/104-MODULES User Manual & Installation Guide VERS. 1.02 DOC: M5124DM.DOC Micro Technic A-S • Denmark • Tel. +45 6615 3000 • Fax +45 6615 3077 E-mail: support@micro-technic.com Website: www.micro-technic.
Users Manual & Installation Guide PV- series: Power supply module with UPS and SSD Flash Description Micronix PV-5124 is a PC/104 Power Supply with 1.76/3.84 MB Flash SSD which provides a convenient way to supply both power and solid state disk capacity to PC/104 bus products. The flash SSD emulates a standard FDD, a complete system can thus be built from just one Micronix PV-5124 and one PC/104 CPU.
Users Manual & Installation Guide PV- SERIES: Power supply module with UPS and SSD Flash FEATURES AND SPECIFICATIONS Power Supply • Output power capability: • Input voltage: • Output voltage: • • • • • Line regulation(+5V) Load regulation(+5V) Load regulation(+12V) Load regulation(-12V) Ripple/noise: • LED indicators: 30W(max) 8-30 VDC or 16-30 VDC using battery charger for 12V battery +5V @5A (max) +12V @250mA(max) -12V @100mA(max) 0.3% - @low line to high line; full load 0.
Users Manual & Installation Guide MODEL SELECTION PV- series: Power supply module with UPS and SSD Flash PV - 512XY-S Disk capacity 0=No SSD 2=1.76 MB 4=3.84 MB A = without UPS and battery charger S = Stack-through AVAILABLE MODELS Model no. PV-5120-S PV-5122-S PV-5124-S PV-5120A-S Page 4 of 8 Description/Type PS with UPS, Stack-through PS with UPS and 1.76 MB SSD, Stack-through PS with UPS and 3.84 MB SSD, Stack-through PS, Stack-through, without UPS and battery charger.
Users Manual & Installation Guide PV- SERIES: Power supply module with UPS and SSD Flash INSTALLATION GUIDE PRECAUTIONS TO ESD Please note, that the Micronix PV modules must be handled with respect to ESD (Electrostatic Discharge). Electrostatic Discharge to the PV modules must be avoided. Before removing the module from the protection bag, the user must be discharged using a grounded wrist ribbon.
Users Manual & Installation Guide PV- series: Power supply module with UPS and SSD Flash I/O MAP AND MEMORY MAP I/O Map I/O port range used is 250h-257h. Be sure that no other hardware in the system makes use of this I/O range. Memory Map PV-5120 uses no memory range. PV-5122 & PV5124 uses memory range D0000h-D7FFFh. Be sure that no other hardware in the system makes use of this memory range.
Users Manual & Installation Guide PV- SERIES: Power supply module with UPS and SSD Flash SCHEMATIC Page 7 of 8
Users Manual & Installation Guide PV- series: Power supply module with UPS and SSD Flash UPS TIMING Typical discharge/charge Short time dropout of mains Page 8 of 8