HEADERS FOR ICD DEVICES
Some devices have no built-in debug circuitry. Therefore, special ICD versions of these
devices are required for MPLAB ICD 2 operation.
Other devices have built-in debug circuitry and do not require a header to use
MPLAB ICD 2. However, some pins and memory must be used to support the ICD
function. Therefore, for some of these devices, special ICD versions offering additional
pins (and sometimes memory) are available to provide more transparent debugging
capabilities.
Currently-available headers and their associated ICD devices/supported devices are
shown in Table 1.
TABLE 1: HEADER TYPES – ICD DEVICES
Header
Part
Number
ICD Device Used Devices Supported
VDD
Max
8 Pin AC162050 PIC12F675-ICD
(1)
PIC12F629/675 5.5
AC162058 PIC12F683-ICD PIC12F683 5.5
14 Pin AC162052 PIC16F676-ICD
(1)
PIC16F630/676 5.5
AC162057 PIC16F636-ICD PIC12F635, PIC16F636 5.5
AC162055 PIC16F684-ICD PIC16F684 5.5
AC162056 PIC16F688-ICD PIC16F688 5.5
AC162059 PIC16F505-ICD PIC10F200/2/4/6
PIC12F508/509
PIC16F505
5.5
AC162070 PIC16F506-ICD PIC10F220/2
PIC12F510
PIC16F506
5.5
18 Pin AC162053 PIC16F648A-ICD
(1)
PIC16F627A/628A/648A 5.5
AC162054 PIC16F716-ICD PIC16F716 5.5
20 Pin AC162066 PIC16F636-ICD PIC16F639 (Dual die) 5.5
AC162060 PIC16F785-ICD PIC16F785/HV785 5.5
AC162061 PIC16F690-ICD PIC16F631/677
PIC16F685/687/689/690
5.5
Note 1: These devices cannot be programmed or read using MPLAB
®
ICD 2
while GP1/RA1 is high (V
IH). Move circuitry that makes GP1/RA1 high
to another I/O pin during development. See device programming