Specifications
32 
Battery
Secondary 
Microcontroller
SHT21
Temperature and 
Relative Humidity 
Sensor
PIC24F04KA201 
Secondary 
Microcontroller
MRF24J40MB
ZigBee Wireless 
Transceiver
SPI Interface I
2
C Interface
Ground
Power
Figure 9 Secondary Microcontroller Interfacing 
2.4 Relays 
Heating, Cooling, and Air Circulation is accomplished with the help of relays that 
act  as  switches  to  turn  on  and off  these  systems.  The  relays  are  triggered by 
digital logic as a result of readings from temperature and humidity sensors. In all 
of the  relays that we have encountered  in our research the  one that would  be 
best be suited for our design is a normally closed switching electronic relay. In 
the  HVAC  control  we  will  use  relays  to  activate  the  output  to  the  heating,  air 
conditioning and air circulation in response to changes in inside and outside air 
temperature depending on the settings selected by the user via the LCD touch 
screen display. 
The  main control  unit  will  allow  the  user  to  set  a specified  temperature  and 
humidity  comfort  setting.  The  NC  (normally  -  closed)  relay  will  be  closed  and 
activate  the  specific  circuit, or opened  to deactivate the circuit in  order  for  the 
temperature  and  humidity  to  be  achieved.  The  tolerance  and  range  of  the 
temperature and humidity sensors will have a direct affect on the output of the 
relays and the activation or deactivation of each of the three systems. 