Specifications
89 
SLCD5. 
4.5"
3.0"
Figure 45 Connectors and Jumpers Layout of the SLCD5 
(Reprinted with permission from Reach Technologies Inc) 
The  SLCD5  can  utilize  either  RS-232  or  CMOS  logic  levels  for  serial 
communication.  By default the COM0 serial port is configured for RS-232.  The 
COM0 port is usually deemed the “Main” port and is connected to the embedded 
processor to control the display.    The  COM1  port  is  usually  deemed  the  “Aux” 
port and is typically used to update the display bitmaps and macros.  The default 
settings for serial communications is 115200 baud, 8 data bits , no parity, with 1 
stop bit, and software (XON/XOFF) flow control.  The baud rate is changeable. 
Figure 46 that is shown below illustrates a typical communication setup for the 
SLCD5. 
SLCD5
Host 
Processor
Main
PC
AUX
Figure 46 SCLD5 Communication Setup 