^A ^D COMMAND
  22 Change SW2: Software dip switch #2. Below is the ^AB sequence:
 12345678
 ^ABxxxxxxxx  
*******.)))),
******.)))),*
*****.)))),**
*****
RRR
 Power-up Label Format
*****
 000=ALWAYS EPROM Format 1 
*****
 001=ROM or Saved Format File 1
*****
 010=ROM or Saved Format File 2
*****
 011=ROM or Saved Format File 3
*****
 100=ROM or Saved Format File 4
*****
 101=ROM or Saved Format File 5
*****
 110=ROM or Saved Format File 6
*****
 111=ROM or Saved Format File 7
****.))))
 1=Use Saved Format File, 0=Rom Format
***.)))))
 1=Print Button Enable, 0=Disable
**.))))))
 1=Disable Button Use, 0=Enable
*.)))))))
 1=>RESTARTED< Response Enable, 0=Disable
.))))))))
 1=Clear Text Enable, 0=Disable
Position: 
1 Clear Text Function: If enabled, all variable text strings will be erased when a
^D25 is processed. 
2  >RESTARTED< Response: If the printer has been reset and this switch has been
enabled, the printer will respond with to the first poll by sending the
>RESTARTED< message. If additional enquiries are made the printer will respond
normally. The >RESTARTED< message is only sent once after reset. 
3  Button Use: Set to 1, the printer will not allow button use, even for paper feed.
4  Print Button: If this is 0, the button can be used for paper feed, but cannot be
used to initiate label printing. 
5  Power-up Format Type: Defines the power-up label format. This parameter
determines whether to use a saved format file for the power-up label, or a ROM
format (defined by positions 6, 7, and 8). The saved format file must be battery
backed to use the saved format file feature. See Appendix C for configuration
instructions and section 5.3.7 for saved format file information. Please consult your
service organization if changes or additions to the fixed ROM formats are required.
 6,7,8 Power-up Label Format: These switches decide which format to use at power-up.