Operator`s manual
Appendix D Quick Reference Command Summary
400 Operators Manual
85
24 Change SW4: Software dip switch #4. An EEPROM command.
Below is the ^AB sequence. 
 12345678 
 ^ABxxxxxxxx
*******.))
 Always 0
******.)))
 Always 0
*****.))))
 Always 0 
****.)))))
 Always 0 
***.))))))
 1=Auto-size on Power-up, 0=Disable
**.)))))))
 1=Blow-hole Sensing Enable, 0=Disable 
*.))))))))
 Always 0
.)))))))))
 Always 0
29 Printer Statistics:
 0 Print statistics to serial port
 1 Print statistics on a label 
 2 Clear the printed labels variable in the statistics
 3 Clear the printed inches variable in the statistics
30 Change Clock: Use the sequence below to set the time and date of the
optional real-time clock:
^D30 (return)
HH:MM:SS (return)
DD/MM/YY/W (return)
31 Show Clock: This command will send the date and time to the serial port.
32 Reset Machine: Restores printer to power-up settings. Also used to set the
EEPROM fields in memory. Section 5.3.
33 Display Model and Revision Number. 
35 Contrast Window Adjust: 
 1 60% of Base
 2 70% of Base
 3 80% of Base
 4 90% of Base
 5 Base (default) 
 6 110% of Base
 7 120% of Base
 8 130% of Base
 9 140% of Base
XX 36 Adjust Contrast Base: An EEPROM command. The ^AXX is between 10 and
200%. Section 5.3. 










