Warning and Caution
THIS GATEWAY IS ACCEPTABLE FOR OPERATION IN AMBIENT CONDITIONS NOT
EXCEEDING __60__ C (__140__ F);
NO SERVICEABLE PARTS OR NO USER SERVICEABLE PARTS. DO NOT OPEN FOR
CLEANING.;
CAUTION - TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES,
DISCONNECT THE GATEWAY FROM THE SUPPLY CIRCUIT BEFORE OPENING. KEEP
TIGHTLY CLOSED WHEN IN OPERATION. ;
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED;
CAUTION RISK OF SHOCK and DISCONNECT POWER BEFORE SERVICING .
AC ONLY
Mounting methods that comply with the requirements in NEC and CEC should be used.
B.3 ATEX & IECEx Marking
Applications:
The device in this series are capable of offering for hazardous locations and
temporary projects, such as quick plant turnarounds, MRO projects, oil fields, marine
sites and tank cleaning etc. Our gateway is designed for Zone 2 environments.
Certifications and compliances:
Ex marking:
IECEx: Ex nA IIC T4 Gc or Ex ec IIC T4 Gc;
ATEX Directive : II 3 G Ex nA IIC T4 Gc or II 3 G Ex ec IIC T4 Gc
IP66
Applicable Standard:
EN60079-0/18 or EN60079-0/7
IEC60079-0/18 or EN60079-0/7
Warning and Caution
WARNING DO NOT OPEN WHEN ENERGIZED
WARNING DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS
PRESENT
End user shall use certified cable gland suitable type of protection for final