5.1.4. Kill:
To kill a tag, typing in a kill password as shown in Figure 25. For more information about Kill and
Kill Passwords please reference the Class 1 Generation 2 UHF Air Interface Protocol Standard
“Gen 2” at htp://www.epcglobalinc.org/standards/uhfc1g2
Figure 25
5.1.5. NXP Command
To perform NXP command for NXP tag, select “Command” to configure with access password as
shown in Figure 26. Otherwise, if you select “ChangeConfig 09-00”, you must set “Configuration”
item. For more information about NXP command, please reference the SL3ICS1002/1202
UCODE G2xM and G2XL at
http://www.nxp.com/documents/data_sheet/SL3ICS1002_1202_139036.pdf
NXP Command
Set Read Protect 02-01: Enable reliable read protection of the entire G2X
memory.
Unset Read Protect 02-00: Reset the ReadProtect-bit and re-enables
reading of the G2X memory content according the EPCglobal specification.
Change EAS ON 01-01: An EAS-Alarm bit set to ‘1’ the tag will reply to an
EAS_Alarm command by backscattering a 64 bit alarm code.
Change EAS OFF 01-00: An EAS-Alarm bit set to ‘0’ the tag will not reply to
an EAS_Alarm command by backscattering a 64 bit alarm code.
Trigger EAS Alarm: Reply an EAS_Alarm command by backscattering a 64
bit alarm code without the need of a Select or Query.