User Manual

MHX-920 Operating Manual: Chapter 5 Installation 41
5.2 Antennas and Cabling
This section describes the recommended procedure for installing cabling
and antennas for use with the MHX-920 module.
5.2.1 Internal Cabling
The most common method for installing the module is to run a cable from
the module’s MCX connector to a reverse TNC bulkhead connector on the
chassis of the equipment as shown in Figure 11. This cable can be
purchased from Microhard Systems.
RG316 Cable
with MCX male
connector
and Reverse TNC
bulkhead
connector
Reverse TNC Connector
MCX female connector
MHX-910
Figure 11. Suggested Internal Cabling
Cable losses are negligible for the short piece used within the chassis.
Additional losses up to 0.5 dB may be present in the MCX and Reverse
TNC connections.