MHX-900 Operating Manual: Appendix D Modem Setup Overview 25
D. Modem Setup Overview
The required commands required to setup an MHX-900 module for point-to-point and point-to-multipoint are
summarized below. These requirements will get you started and only ensure that a link can be established, but do
not necessarily provide the best performance.
Point-to-Point
To establish a point-to-point communications link, the following commands must be issued by the host EOM
microprocessor:
n The Operating Mode S Register (S101) for one modem must be configured as a Master - Point-to-Point
(1), and the other as a Slave - Point-to-Point(2).
n The Wireless Link Rate S Register (S103) value for both modems must be the same.
n The Network Address S Register (S104) value assigned for both modems must be the same.
n The Unit Address S Register (S105) value assigned for both modems must be the same.
n The same Hopping Pattern S Register (S106) value must be selected for both modems.
n The same Hopping Interval S Register (S109) value must be selected for both modems.
n The same Encryption Key S Register (S107) value must be selected for both modems.
The master can now attempt to synchronize with the slave using the D<slave address> command.
Point-to-Multipoint
To establish a point-to-point communications link, the following commands must be issued by the host OEM
microprocessor:
n The Operating Mode S Register (S101) for one modem must be configured as a Point-to-Multipoint
Master (3), and the other as a Point-to-Multipoint Slave (4).
n The Wireless Link Rate S Register (S103) value for both modems must be the same.
n The Network Address S Register (S104) value assigned for both modems must be the same.
n Each Slave must be assigned an unique Unit Address S Register (S105) value (Unit Address 0 is not
supported).
n The same Hopping Pattern S Register (S106) value must be selected for both modems.
n The same Hopping Interval S Register (S109) value must be selected for both modems.
n The same Encryption Key S Register (S107) value must be selected for both modems.
The master can now attempt to synchronize with the slave using the D<slave address> command.