Connection to Plumbing (cont.)
Acceptable inlet/outlet connections
The Inlet (6) and Outlet (7) water connections are both ½” BSP SERIES GB.
There are three options for inlet/outlet connections with this unit:
Connection to Plumbing (cont.)
Water Inlet Pressure Limiting Valve and Shutoff Valve Connection
The unit is a closed outlet water heater and is intended to operate at the pressure of the water mains, where
the flow of water is controlled by one or more faucets/valves in the outlet line.
The unit can be installed into any type of commercial or residential construction as per the current Plumbing
Standards.
However, it is mandatory for a water pressure limiting valve and a shutoff valve to be connected in series with
the unit’s cold water inlet connection (6).
The unit is designed to operate at 10 MPa/10 bar/150 PSI.
The installation of a pressure limiting valve – a mandatory requirement – ensures that excess water pressure
applied, as result of water hammer and/or other circumstances, does not stress the appliance unduly.
The inline water pressure limiting valve must be rated at 5.0 bar/72.5 psi/500 kpa.
The shutoff valve installed must not be a non-return type valve.
InstallationInstallation
IMPORTANT
MicroHeat nor its Distributors will be liable for any damages through failure to comply with
the installation and operating instructions outlined in this manual – specifically in this instance
where the specified water pressure limiting valve and shutoff valve type, as indicated, must be
installed with this unit.
INLETOUTLET
CFEWH SERIES 1-10
WATER
PRESSURE
LIMITING VALVE
5 bar/500kpa
SHUTOFF VALVE
MUST NOT BE
A NON-RETURN TYPE VALVE
Hot Water OUT
Cold Water IN
Braided Hose without seal
Braided Hose with seal
Straight Copper Tube
A
A
C
E
30°
90°
2.0
E
F
Metal or plastic olive
Min. angle
E
90°
2.0
F
A
12 min
1 min
E
7.0 to 10.0
X
1
2.5
0.1
90°
2.0
F
Metal or plastic olive