4.7 Set the Parameters of Fixed Report Information
Step_1: Select “Fixed Report Information” option.
Step_2: Select “Mode”.
0: disable Fixed Report Function.
1: enable Fixed Report Function.
Step_3: Select “Discard no fix”.
0 to report last known GPS position if there is no GPS fix;
1 to send nothing if there is no GPS fix.
Step_4: Set a group of parameters:
Set “Begin Time” and “End Time”. The start time and end time of scheduled fixed
report. It is noticed to use UTC time here.
Set “Check Interval 1”. The time interval to fix GPS when the terminal is in motion
state. 0 means no check. Default value is 120 seconds.
Set “Send Interval 1”. The period to send the position information when the terminal
is in motion state. 0 means not to send. Default value is 360 seconds.
Set “Check Interval 2”. The time interval to fix GPS when the terminal is in
motionless state. 0 means no check. Default value is 120 seconds.
Set “Send Interval 2”. The period to send the position information when the terminal
is in motionless state. 0 means not to send. Default value is 360 seconds.
Select “Movement Detect Mode”.
0: disable (default)
Step_1
Step_2
Step_4
Step_5
Step_6
Step_3