2009 - 2010 C ATA L O G U E Cabling System CABLES AND ELECTRICAL COMPONENTS 1
CABLES AND ELECTRICAL COMPONENTS www.fanton.
THE ENERGY of values. Daily commitment for timeless quality. Designing new solutions for 19" rack cabinets, developing cables with superior performance, testing new active equipment: it is important to us to believe that our work makes a positive contribution to the work of others. Important for the development of an industrial organisation in search of values which can sustain it in its commitment to globalisation and quality.
Our products are environment-friendly The European Union has issued clear directives to ensure better management of electrical waste throughout the production chain, to safeguard an environment increasingly under threat from problematical waste. Fanton S.p.A. has always responded to the need for sustainable development with strategies which aim to comply with the strict European directives on production, disposal and the environment.
CONTENTS 2009 2010 PRESENTATION 1 • Our products are environment-friendly (ROHS – RAEE) 3 QUICK GUIDE 6 INTRODUCTION 8 • About Cabling System 8 CONCEPT SYSTEM 11 LAN CABLES 13 • • • • • • • • • • • U/UTP – F/UTP – SF/UTP U/UTP U/UTP – F/UTP F/UTP U/UTP – F/UTP – SF/UTP U/UTP – F/UTP F/UTP U/UTP F/UTP F/FTP – S/FTP S/FTP Cat. 5e cables Cat. 5E Flex cables Cat. 5e cables with PE sheaths Cat. 5e cable with double PVC sheath Cat. 6 cables Cat. 6 cables with PE sheaths Cat.
Fixed and sliding drawers Ventilation systems Miscellaneous accessories Power bars Work area accessories 55 56 56 58-59 60 PHONE SYSTEM 61 • Telephone switching systems 62 DATA SYSTEM 5E 63 • Cat. 5e cabling systems 64-65-66-67 DATA SYSTEM 6 69 • Cat. 6 cabling systems • Tools 70-71 72 DATA SYSTEM 6A 73 • Cat.
QUICK GUIDE Codice QUICK GUIDE 2009 2010 6 22312 22386 23000 23001 23002 23003 23010 23011 23012 23013 23080 23081 23082 23083 23084 23085 23086 23087 23088 23089 23090 23091 23092 23093 23094 23095 23096 23097 23098 23099 23104 23105 23106 23107 23108 23109 23110 23111 23112 23113 23114 23123 23124 23125 23126 23127 23128 23129 23130 23131 23132 23133 23134 23135 23136 23137 23138 23141 23142 23143 23144 23145 23146 23147 23148 23149 23150 23151 23152 23153 Pag. Codice Pag. Codice Pag.
23953 23954 23955 23956 23981 23982 23983 23990 23991 23993 23994 23997 23998 23999 24000 24001 24003 24004 24005 24006 24008 24009 24010 24011 24012 24013 24014 24015 24016 24017 24018 24019 24020 24091 24092 24093 24094 24095 24096 24097 24098 24100 24101 24102 24103 24104 24105 24106 24107 24108 24109 24110 24111 24113 24114 24115 24116 24117 24118 24120 24121 24124 24126 24127 24128 24129 24130 24131 24141 24142 Pag. Codice Pag. Codice Pag.
INTRODUCTION Such systems are composed of subsystems as follows: This catalogue is designed to aid users, installation technicians and industry professionals in selecting cabling system components. The catalogue is divided by sector, both from the point of view of theory and product range. The theoretical part is a brief summary, since the details are dealt with in a separate telecommunications manual.
▼ MACHINE ROOMS Importante come lo studio dell’area di lavoro nella progettazione è la organizzazione dei locali tecnici, essi non solo definiscono la centralità del sistema e il loro sviluppo ma sono l’anello di congiunzione con ampliamenti e successivi livelli degli impianti.
STANDARDS MAPS INTRODUCTION 2009 2010 ILLUSTRATION OF SYSTEM AREA COLOUR CODES Orange Green Purple White Grey Blue Brown Yellow Red 10 – Demarcation point. – Networking and auxiliary equipment. – Mainframe, PBX, computer, multiplexer. – First switching level MC-CD//IC-BD – Second switching level IC-BD//HC-FD. – Horizontal cabling. – Building backbone. – Alarms, safety, auxiliary, mixed systems. – Available for future use.
Training, assistance and warranty, total cabling Fanton S.p.A. has been a manufacturer of electrical equipment for more than 25 years. Now, with the FANTONet brand, we are also manufacturers of a full range of products for cabling systems and, with our "ENERGY MASTER" training courses, we are opening a new phase in our history as a leader in the industry, by providing an important opportunity for growth and requalification to all installation technicians. Fanton S.p.A.
▼ WARRANTY CONCEPT SYSTEM 2009 2010 12 and economic requirements, aims to provide the most advantageous solution for applications running from building construction to refurbishment… …to practical and theoretical TRAINING courses run by skilled technicians and authoritative representatives of our partner organisations, with the aim of certifying participants, be they electricians or sales technicians to our prestigious company standards (FANTONet Qualified Installation Technician, FANTONet Qualified Tec
LAN CABLES • • • • • • • • • U/UTP - F/UTP - SF/UTP Cat. 5E cables U/UTP Cat. 5e Flex cables U/UTP - F/UTP Cat. 5e cables with PE sheath F/UTP Cat. 5e cables with double PVC sheath U/UTP - F/UTP - SF/UTP Cat. 6 cables U/UTP Cat. 6 cables with PE sheath F/UTP Cat. 6 cables with PE sheath F/UTP Cat. 6 cables with double PVC sheath U/UTP Cat. 6A cables with PVC and LSZH sheath 10 Gigabit • F/UTP Cat. 6A cables, 550 Mhz 10 Gigabit • F/FTP - S/FTP Cat. 6A cables, 550 Mhz 10 Gigabit • S/FTP Cat.
U/UTP Cat. 5e Data transmission cables - gauge AWG 24 Codes A82500 (Box 305m) - A82506 (Coil 500m) - A82507 (Coil 1000m) – PVC Codes A82550 (Box 305m) - A82556 (Coil 500m) - A82557 (Coil 1000m) – LSZH Applications: Applicable standards: Connection system: Installation: Directives: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
F/UTP Cat. 5e Data transmission cables - gauge AWG 24 screen Codes A82510 (Box 305m) - A82516 (Coil 500m) - A82517 (Coil 1000m) – PVC Codes A82560 (Box 305m) - A82566 (Coil 500m) - A82567 (Coil 1000m) – LSZH Applications: Applicable standards: Connection system: Installation: Directives: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
SF/UTP Cat. 5e Data transmission cables - gauge AWG 24 Double screen Code A82526 (Coil 500m) – PVC Code A82576 (Coil 500m) – LSZH Applications: Applicable standards: Connection system: Installation: Directives: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
U/UTP Cat. 5e FLEX Data transmission cables - gauge AWG 24/7 Codes A82600 (Box 305m) - A82606 (Coil 500m) - A82607 (Coil 1000m) – PVC Applications: Applicable standards: Connection system: Installation: Directives: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
U/UTP Cat. 5e Black PE sheath Data transmission cables - gauge AWG 24 double sheath Codes A82456 (Coil 500m) - A82457 (Coil 1000m) – PE Applications: Applicable standards: Connection system: Installation: Directives: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
F/UTP Cat. 5e Black PE sheath Data transmission cables - gauge AWG 24 Screen, double sheath Codes A82486 (Coil 500m) - A82487 (Coil 1000m) – PE Applications: Applicable standards: Connection system: Installation: Directives: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
F/UTP Cat. 5e - Double screen Isolation PVC GR° 4 BLUE Data transmission cables - gauge AWG 24 Screen, double sheath Code A82477 (Coil 1000m) Applications: Applicable standards: Connection system: Installation: Directives: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
U/UTP Cat. 6 Data transmission cables - gauge AWG 23 Codes A82840 (Box 305m) - A82846 (Coil 500m) - A82847 (Coil 1000m) – PVC Codes A82940 (Box 305m) - A82946 (Coil 500m) - A82947 (Coil 1000m) – LSZH Applications: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
F/UTP Cat. 6 Data transmission cables - gauge AWG 24 shielded Codes A82856 (Coil 500m) - A82857 (Coil 1000m) – PVC Codes A82956 (Coil 500m) - A82957 (Coil 1000m) – LSZH Applications: Sistemi di cablaggio strutturato trasmissione dati ad alta frequenza. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
SF/UTP Cat. 6 Data transmission cables - gauge AWG 24 Double screen Codes A82866 (Coil 500m) - A82867 (Coil 1000m) – PVC Codes A82966 (Coil 500m) - A82967 (Coil 1000m) – LSZH Applications: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
U/UTP Cat. 6 Black PE sheath Data transmission cables - gauge AWG 23 Double sheath Code A82426 (Coil 500m) – PE Code A82427 (Coil 1000m) – PE Applications: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
F/UTP Cat. 6 - Double screen Isolation PVC GR° 4 BLUE Data transmission cables - gauge AWG 24 Screen, double sheath Code A82876 (Coil 500m) - A82877 (Coil 1000m) – PVC Applications: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
F/UTP Cat. 6 Black PE sheath Data transmission cables - gauge AWG 24 Double sheath Code A82436 (Coil 500m) – PE Code A82437 (Coil 1000m) – PE Applications: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
U/UTP Cat. 6A - 550 Mhz 10 Gigabit Data transmission cables - gauge AWG 23 Codes A82750 (Box 305m) - A82756 (Coil 500m) - A82757 (Coil 1000m) – PVC Codes A82740 (Box 305m) - A82746 (Coil 500m) - A82747 (Coil 1000m) – LSZH Applications: Applicable standards: Connection system: Installation: Directives: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
F/UTP Cat. 6A - 550 Mhz 10 Gigabit Data transmission cables - gauge AWG 24 LSZH Double screen Code A82716 (Coil 500m) – LSZH Code A82717 (Coil 1000m) – LSZH Applications: Applicable standards: Connection system: Installation: Directives: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
F/FTP and S/FTP Cat. 6A 550 Mhz 10 Gigabit Data transmission cables - gauge AWG 23 LSZH F/FTP Code A82726 (Coil 500m) – LSZH F/FTP Code A82727 (Coil 1000m) – LSZH Applicable standards: Connection system: Installation: Directives: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet, 10GBASE-T EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
S/FTP Cat. 7 10 Gigabit Data transmission cables - gauge AWG 23 Double screen Codes A82886 (Coil 500m) A82887 (Coil 1000m) – PVC Codes A82986 (Coil 500m) A82987 (Coil 1000m) – LSZH Applications: Applicable standards: Connection system: Installation: Directives: High frequency data transmission cabling systems. IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.
TRANSMISSIVE PARAMETERS The electrical parameters of a cable are essentially determined by its mechanical parameters. The relation between them cannot, however, be reduced to simple formulae, especially at high frequencies, where electromagnetic phenomena must be considered in addition to purely electrical ones. The following parameters apply to screened/unscreened cable connections and are basic measures, in other words, the cable’s dataplate data.
▼ PSNEXT - Power Sum Next; The inductive coupling of the sum of the near end crosstalk of all disturbing pairs on a single disturbed pair. ▼ PSACR - Power Sum Attenuation to Crosstalk Ratio; The ratio between the signal and the sum of disturbances (IL and NEXT) of all disturbing pairs on a single disturbed pair. ▼ ▼ AXT - Alien Cross Talk; Disturbo indotto su una o più coppie di un cavo dei segnali propagatesi su coppie appartenenti a cavi diversi.
OPTICAL FIBRE CABLES • "LOOSE" optical fibre • "LOOSE" REINFORCED optical fibre • "TIGHT" optical fibre • "MULTITUBE" optical fibre • "BREAK-OUT" optical fibre
"LOOSE" optical fibre For indoors/outdoors installation Data transmission optical fibre cables OM1 OM2 OM3 OS1 (multimode and singlemode) From 4 to 24 fibres - Dielectric reinforcement - LSZH external sheath 62.5/125 OM1, 50/125 OM2, 50/125 OM3, 9/125 OS1 ▼ DESCRIPTION LOOSE type cables are suited for both indoors and outdoors installation thanks to their robust, simple construction.
"LOOSE" reinforced optical fibre For outdoors installation Data transmission optical fibre cables OM1 OM2 OM3 OS1 (multimode and singlemode) 4 to 24 fibres - outdoors installation - steel reinforcement - PE jacket 62.5/125 OM1, 50/125 OM2, 50/125 OM3, 9/125 OS1 ▼ DESCRIPTION This optical fibre cable features a simple, but very robust construction.
"TIGHT" optical fibre For indoors installation Data transmission optical fibre cables OM1 OM2 OM3 OS1 (multimode and singlemode) From 4 to 24 fibres - Dielectric reinforcement - LSZH jacket ▼ DESCRIPTION "Tight" type cables are suited for indoors installation and are available according to colour standards with 900 micron coloured fibre sheaths. The single tube is composed of a single bundle of fibre strands surrounded by glass fibres to give it traction resistance and resistance against attack by rodents.
Multitube optical fibre 24/144 fibre Steel reinforced For outdoors or underground installation Data transmission optical fibre cables OM1 OM2 OM3 OS1 (multimode and singlemode) ▼ DESCRIPTION Reinforced multitube cables are suited for outdoors and directly underground installation, with polyethylene jacket. The reinforcement is composed of a corrugated steel tube waterproofed with a tape. The fibres are available according to colour standards, with 250 micron coloured sheaths.
"BREAK-OUT" optical fibre For indoors/outdoors installation Optical fibre cables for data transmission OM1 OM2 OM3 OS1 (multimode and singlemode) ▼ DESCRIPTION "Break-out" type cables are multi-tight cables suited for indoors installation and are available according to colour standards with 900 micron coloured fibre sheaths.
OPTICAL FIBRE CABLES Optical fibre is a transmissive medium which carries photons (light) rather than electrical current, as is the case for normal copper conductors. The fundamental requirement for this type of transmission is thus that the material be transparent, like glass, rather than a good conductor. Optical fibres are composed of thin fibres of silicon oxide (SiO2), which act as tunnels to transport the light to distant destinations. This "tunnel" is extremely small; it is measured in microns.
▼ ATTENUATION As it travels along the fibre’s core, the light will attenuate under the action of four factors: 1) ABSORPTION This is caused by impurities in the fibre which absorb the light; such impurities in the glassy matrix of the fibre are due to the presence of hydroxide compounds (OH). 2) SCATTERING This is caused by variable density of the material or at the molecular level in the fibre’s glassy matrix. Scattering is at the basis of the OTDR concept (Optical Time Domain Reflectometer).
GREENET ENCLOSURES • 10" Greenet Minilan panels • 19" Greenet wall panels • Greenet swing out panels • 19" Greenet floor enclosures • IP55 enclosures • 19" open racks • Kit-Net • Enclosure accessories
WALL-MOUNT PANELS GREENET 19" RACK SERIES GREENET ENCLOSURES AND PANELS 2009 2010 42 TITLE Ref. • • • • • • • • • • 1 2 3 4 5 6 7 8 9 10 Base Upright Top panel Side panel M 5x12 welded pin Buffer flange M5 nut Internal upright Rear door Front door Floor enclosures GREENET 19" RACK SERIES TITLE Ref.
10" GREENET MINILAN PANEL ▼ GENERAL CHARACTERISTICS In order to satisfy the requirement for minimum overall dimensions, the Greenet line also has a wall panel version which designed for installation in restricted spaces. The Minilan version panel maintains the characteristics of the standard versions, including: completely disassemblable panel, key opening, side panel opening, tempered glass door, top and bottom cable access flanges. The only difference is in size, which is 10" rather than the standard 19".
GREENET 19" WALL PANELS ▼ GENERAL CHARACTERISTICS The Greenet series of panels includes, in the 19 inch rack wall version, a wide range of products. In fact, starting from 6 unit racks, the range goes on to 9U, 12U, 15U and 20 unit racks. To provide greater flexibility these latter two products (15 and 20 unit racks) can be transformed into floor units with an accessory plinth.
■ GREENET 19" wall panels - depth 600 mm Code Dimensions (lxwxh) Units 23090 23095 610 x 600 x 390 mm 610 x 600 x 390 mm 6 6 23091 23096 610 x 600 x 520 mm 610 x 600 x 520 mm 23092 23097 Colour Package Pack Pcs ■■■■ ■■■■ (*) Carton Carton 1 1 9 9 ■■■■ ■■■■ (*) Carton Carton 1 1 610 x 600 x 650 mm 610 x 600 x 650 mm 12 12 ■■■■ ■■■■ (*) Carton Carton 1 1 23093 23098 610 x 600 x 780 mm 610 x 600 x 780 mm 15 15 ■■■■ ■■■■ (*) Carton Carton 1 1 23094 23099 610 x 600 x 1000 mm 610 x
GREENET 19" FLOOR ENCLOSURES ▼ GENERAL CHARACTERISTICS We can now offer a sealed IP 55 version for areas in which telecommunications equipment must be isolated from the exterior, and a stainless steel version for areas where washability and corrosion resistance are important.
■ Greenet 800x800 floor enclosures Code Dimensions (lxwxh) Package Pack Pcs 23141 23181 800 x 800 x 1200 mm 800 x 800 x 1200 mm Units 24 24 ■■■■ ■■■■ (*) Colour Carton Carton 1 1 23142 23182 800 x 800 x 1500 mm 800 x 800 x 1500 mm 31 31 ■■■■ ■■■■ (*) Carton Carton 1 1 23134 23154 800 x 800 x 1800 mm 800 x 800 x 1800 mm 38 38 ■■■■ ■■■■ (*) Carton Carton 1 1 23135 23155 800 x 800 x 2000 mm 800 x 800 x 2000 mm 42 42 ■■■■ ■■■■ (*) Carton Carton 1 1 23136 23156 800 x 800 x 2200 mm
RACK EASYNET The range of racks proposed by Fanton, is now wider: a new version called Easy net was introduced. It contemplates the proposals with 6-9-12-15-20 units, just like the Greenet racks. These racks are built in conformity to the IEC 297-1 standards, and studied to be satisfactory for people who need the simplest installation and quick mounting device.
GREENET: modularity and ease of installation. All Greenet series enclosures, both wall and floor models, can be completely disassembled with a single 10mm socket driver. They are constructed in such a way that the four uprights are fixed to the top and bottom panels with and insert and just 2 bolts each, so that 16 bolts are used to assemble the entire structure.
KIT-NET NET enclosure kit Cat. 6 complete for 24 users NET enclosure kit Cat. 5e complete for 24 users Cod 99905 Cod 99902 23124 KIT-NET 2009 2010 Complete, ready-to-use solutions. 23124 GREENET 19" rack wall panel 610 x 400 x 390 mm 6 units • grey quantity: 1 23652 GREENET 19" rack wall panel 610 x 400 x 390 mm 6 units • grey quantity: 1 23422 Patch Panel 24 ports 1 unit for 600mm 19" rack enclosures complete with RJ45 Cat.
The MINILAN kit, ideal for domestic and similar network applications, offers a full range of accessories pre-installed on the panel: cable, sockets, patch cords, power bar. For medium size installation there are other wall versions, which can also be equipped with an accessory plinth since, as is often the case, 15 unit enclosures offer an excellent aesthetic and functional solution even when floor mounted, although originally designed for wall mounting. NET enclosure kit Cat.
CABINET ACCESSORIES ■ Empty patch panels (REQUIRE coloured windows art. 23.800 and successive) ▼ TECHNICAL CHARACTERISTICS • Steel sheet, 1.
IDENTIFICATION SYSTEMS ■ Coloured windows Code Description 23800 23801 23802 23803 23804 Windows for empty patch panels Windows for empty patch panels Windows for empty patch panels Windows for empty patch panels Windows for empty patch panels Colour Package Pack Pcs ■■■■ ■■■■ ■■■■ ■■■■ ■■■■ Bag 20 pcs Bag 20 pcs Bag 20 pcs Bag 20 pcs Bag 20 pcs 100 100 100 100 100 Colour Package Pack Pcs ■■■■ ■■■■ ■■■■ ■■■■ ■■■■ Bag 2 sets Bag 2 sets Bag 2 sets Bag 2 sets Bag 2 sets 10 10 10 10 10 Colour P
19" ROTARY RACKS ▼ GENERAL CHARACTERISTICS Designed specifically to facilitate access to the rear of cabling systems, simplifies normal cabling and maintenance since it can be opened to the right and the left. Made in 15/10 steel sheeting, embossed epoxy powder coating RAL 7035, easy to install and secures to the enclosure structure with socke cap head screws.
DRAWERS FOR ENCLOSURES ▼ GENERAL CHARACTERISTICS Drawers play an essential role in enclosures inasmuch as they provide support for all those accessories and devices which are not designed for use on 19" racks and hence have no attachments for this type of structure. For example, they can be used to support a computer, monitor, keyboard, UPS etc. Given the wide range of enclosures on offer and the various applications they are used for, our drawers are divided into two main groups.
VENTILATION PANELS 23345 ▼ GENERAL CHARACTERISTICS Panels for forced ventilation of enclosures are in the 19 inch rack format and occupy a height of 3 modules. There are two versions: one with two ventilators for normal air exchange, and one with three ventilators for improved heat dissipation, especially for transformers and equipment powered inside the enclosure itself. Both versions are pre-cabled and equipped with power terminals, which may be direct or controlled.
■ Cable routing flange Code Description 23305 23306 Flange complete with dust brush Blind flange Colour Package Pack Pcs ■■■■ ■■■■ Polyethylene Polyethylene 1 1 23305 ■ Document wallet Code Description 23310 PVC document wallet, A4 Colour Package Pack Pcs ■■■■ Heat shrink 1 Package Pack Pcs Carton 50 pcs 1 ■ Mounting accessories Code Description 23320 Kit viti e dadi a gabbia M6 23310 ■ Straps Code Length mm Width mm Strap dia.
POWER BARS The new FANTONET power bars are constructed, like previous models, in polycarbonate (PC) for lightweight and ease of use. To this is added the convenience of the 19" rack standard in terms of sizing. The new series of power bars have a single rack unit footprint (44 mm) and are hence ideal for installation in telecommunications enclosures. There are three versions, with lamp switch, with lamp switch and overvoltage protection, and with thermal cutout.
■ Power bars for MINILAN 10" rack enclosures 23214 23215 2 1+2 2P+T 16A Italian/German with lamp switch 2 x 2P+T 16A Double-pitch + 1 x 2P+T 16A Italian/German with lamp switch ■■■■ ■■■■ Bag Bag 1 1 23214 ■ Vertical power bars for 19" rack enclosures Outputs 23220 8 23221 8 23222 10 23223 10 23224 12 23225 12 23226 16 23227 16 Description Colour Package Pack Pcs 2P+T 16A Italian/German with lamp switc and overvoltage protection 2P+T 16A Italian/German with thermal cutout ■■■■ Ba
WORK AREA ACCESSORIES 23930 23927 23932 23939 23935 23937 WORK AREA ACCESSORIES 2009 2010 ■ Adapters for mounting to socket plates and supports Code Description 23922 23923 23924 23925 23926 23927 23928 23929 23930 23931 23932 23933 23934 23935 23936 23937 23938 23939 Adapter for socket plates and supports Adapter for socket plates and supports Adapter for socket plates and supports Adapter for socket plates and supports Adapter for socket plates and supports Adapter for socket plates and supports A
PHONE SYSTEM • Telephone switching systems
TELEPHONE SWITCHING SYSTEMS (Phone System) ■ ADSL filters 22386 Code Description 22386 23759 Phone switcher for ADSL line, 2 ports + plug Phone switcher for ADSL line, 3 ports Colour Package Pack Pcs ■■■■ ■■■■ None None 1 1 Colour Package Pack Pcs ■■■■ Bag 10 ■■■■ Bag 10 ■ 6/6c RJ12 sockets (Keystone jack) Cat. 3 Code Description 23708 6/6 horizontal TOOLESS socket, not screened Cat. 3 RJ12 telephone 6/6 horizontal TOOLESS socket, not screened Cat.
DATA SYSTEM 5e • Data System 5e Switching system • Patch Panel • Patch Cords • Type 110 switching systems
DATA SYSTEM 5e SWITCHING SYSTEM ▼ GENERAL CHARACTERISTICS The most widely used cabling systems at the present time are those with 100 Mhz bandwidth and Fastethernet protocol, in other words Cat. 5e. These were considered cutting edge in data transmission a years ago, nowadays they are considered an excellent compromise between performance and cost. These systems are presently best suited for large and small installations using the most common control software.
DATA SYSTEM 5e PATCH PANEL ▼ GENERAL CHARACTERISTICS Patch panels and modules are the devices to which connectors are installed. They may be screened or unscreened, depending on the quality and type of signal to be transmitted, and are of different sizes, depending on the quantity of users to be supplied.
DATA SYSTEM 5e PATCH CORDS ▼ GENERAL CHARACTERISTICS The length of connections is an essential factor in the flexibility of the installation. ISO/IEC 11801 establishes that the maximum permitted length of the horizontal copper cable running from the distribution enclosure to the user socket is 90 m. On the other hand, the sum of the lengths of the flexible twisted pair patch cords used for connections inside the enclosure and for the socket/terminal connection, may not exceed 10 m.
TYPE 110 SWITCHING SYSTEM ▼ GENERAL CHARACTERISTICS 110 type switching systems are ideal for connecting cabling systems, existing telephone systems, line-ins or telephone switchboards, as well as sectioning telephone backbones composed of multi-pair cable. Indeed, by using 100cp / 200cp patch panels and 110RJ45 patch cords, it is possible to transfer a signal from a pair of a multi-pair cable to a LAN cable line. Given that the system is Cat.
THE IMPORTANCE OF EXPERT INSTALLATION FURTHER INFORMATION 2009 2010 68
DATA SYSTEM 6 • Data System 6 Switching system • Tools
DATA SYSTEM 6 SWITCHING SYSTEM ▼ GENERAL CHARACTERISTICS With the passing of time, technological progress allows for the diffusion and use of ever more complex hardware and software. Since increasing numbers of users are authorised to use such resources, networks must be specified to handle increasingly heavy traffic loads. What is required today in systems with high transmission requirements will tomorrow be quite normal; this is why Cat.
■ Empty patch panels 19" rack (art. 3702 - 23704 - 237010 - 23711 - 23712 only) Code Description 23662 Screened empty panel 24 ports, complete with rear cable guide - 1 unit Screened empty panel 24 ports, complete with rear cable guide - 1 unit 23667 Colore Package Pack Pcs ■■■■ Carton 1 ■■■■ Carton 1 23662 23667 ■ UTP Cat. 6 patch cord Description Length Colore Package Pack Pcs 23540 23541 23542 23543 23544 UTP patch cord UTP patch cord UTP patch cord UTP patch cord UTP patch cord 0.
TOOLS ▼ GENERAL CHARACTERISTICS Crimping tools are essential for connecting cables, sockets and patch panels. Dispersion is highest at the connections between passive components. To optimise transmission performance, you must use tools specially designed to make the most of the various physical supports. Badly executed crimping generates attenuations which can even declassify the category of a cabling system; this aspect must be treated with the proper care and attention.
DATA SYSTEM 6A 10 GIGA • Data System 6A Switching system • Tools
DATA SYSTEM 6A 10 GIGA SISTEMA DI PERMUTAZIONE ■ 8/8c RJ45 sockets (Keystone jack) Cat. 6A 23715 Code Description 23715 23716 23717 Vertical unscreened socket - Cat. 6A Vertical screened socket - Cat. 6A Vertical unscreened socket - Cat. 6A Colour Package Pack Pcs ■■■■ ■■■■ ■■■■ Carton Carton Carton 10 10 10 Colour Package Pack Pcs ■■■■ Carton 1 ■■■■ Carton 1 N.B.: Fitting RJ11 and RJ12 telephone plugs can damage the socket, we recommend using RJ45 plugs also for telephony applications.
DESIGN BASICS ■ "FIBER TO THE DESK" SOLUTIONS ■ COMPARING ARCHITECTURES ■ THE PERMANENT LINK A Permanent Link consists of a LAN cable plus Keystone sockets at each end ■ THE CHANNEL The Channel consists of the Permanent Link plus the patch cords for switching FURTHER INFORMATION 2009 2010 75
RJ45 SOCKETS The two crimping methods are equivalent, but cannot coexist in a single installation. It follows that once the type of connection (A or B) has been chosen for a cabling system, it cannot be changed. The untwisted length of a section of cable as the result of a termination towards a connecting component must be as short as possible. Only the absolutely necessary amount of wire must be unwound for terminating and finishing the cable.
LIGHT SYSTEM • Optical fibre connectors and sockets • Pigtails • Optical fibre patch cords • Optical fibre connection accessories
OPTICAL FIBRE CONNECTORS AND SOCKETS ■ LightCrimp connectors 24110 24111 Code Description 24109 24110 24111 ST-LightCrimp SM connector ST-LightCrimp MM connector SC-LightCrimp MM connector Ferrule Package Pack Pcs PC PC PC Bag 1 pcs Bag 1 pcs Bag 1 pcs 1 1 1 Ferrule Package Pack Pcs PC PC PC PC Bag 1 pcs Bag 1 pcs Bag 1 pcs Bag 1 pcs 1 1 1 1 Ferrule Package Pack Pcs UPC UPC UPC UPC UPC UPC UPC UPC Bag 1 pcs Bag 1 pcs Bag 1 pcs Bag 1 pcs Bag 1 pcs Bag 1 pcs Bag 1 pcs Bag 1 pcs 1 1 1 1
PIGTAILS - OPTICAL JUNCTION BOXES ■ Pigtails Code Description Length Package Pack Pcs 24141 24142 24143 24161 24146 24147 24148 24166 24151 24152 24153 24171 ST 62,5/125 pigtail FC 62,5/125 pigtail LC 62,5/125 pigtail SC 62,5/125 pigtail ST 50/125 pigtail FC 50/125 pigtail LC 50/125 pigtail SC 50/125 pigtail ST 9/125 pigtail FC 9/125 pigtail LC 9/125 pigtail SC 9/125 pigtail 2.0 m 2.0 m 2.0 m 2.0 m 2.0 m 2.0 m 2.0 m 2.0 m 2.0 m 2.0 m 2.0 m 2.
OPTICAL FIBRE PATCH CORDS ▼ GENERAL CHARACTERISTICS The fibre optic patch cords listed in this catalogue are of the tight type, and are individually coated (monofibre optical fibre) with materials which ensure considerable flexibility combined with mechanical strength. The cords terminate with crimped connectors of various types depending on the intended application.
■ Multimode optical patch cords 50/125 - UPC Type Code Description Ferrule Length Colour Package Pack Pcs 24286 24282 24283 24284 Double-fibre patch cords LC/LC 50/125 Double-fibre patch cords LC/LC 50/125 Double-fibre patch cords LC/LC 50/125 Double-fibre patch cords LC/LC 50/125 PC PC PC PC 1.0 m 2.0 m 3.0 m 5.
OPTICAL FIBRE CONNECTION ACCESSORIES ■ "Light-crimp Easy" fibre optic kit ▼ GENERAL CHARACTERISTICS Optical fibre is the best choice whenever the connection must not only be of high quality, but also longer than 90 m, which is the limit for copper connections according to established regulations. In order to use this particular technology, the user needs the crimping equipment required for hooking up fibre cables.
■ Optical fibre glue termination kit ▼ GENERAL CHARACTERISTICS As an alternative to the optical fibre kits described above, intended for cold crimping connectors, we also offer the glue alternative. Instead of crimping pliers, this kit includes a set of glues and the cleaning equipment required for terminating the fibre with the connector.
MPO SYSTEM ▼ INTRODUCTIONS Easy and quickly plug and play fibre optic connection system. 24182 ■ MPO System 24190 24184 MPO Cable MPO SYSTEM 2009 2010 Code Description Code on request Code on request MPO Cable12 F. MM 50/125 Mt. Xx MPO Cable 12 F. SM 9/125 Mt.
TOWER TECH SERIES • Columns and towers • Multi-sockets
ENERGY D AT E TV S AT PHONE TOWERTECH P O W E R A N D D ATA D I S T R I B U T I O N T O W E R S The TOWER TECH series of towers provides a combined solution to two fundamental needs by distributing both power and data through a single product. With TOWER TECH, both sockets can be brought close to the user device, thus reducing loose cable to a minimum.
TECHNICAL CHARACTERISTICS CABLE REE fitted on the side of the tower to house any excess cable 4 STANDARD SIZES Vertical 45, 65 or 100 cm in height or horizontal (desktop) 45 cm wide STANDARDS Supplied with Italian/German standard sockets, also available with English and French sockets, and RJ45 telecommunications sockets CONNECTION FITTING to secure a tubular duct for the power supply or for stacking additional towers (up to 3 pieces) if required CAVITY FLOORS Ideal for cavity floors, since connections
2 WIRING CONNECTIONS AND THE INSTALLATION IS COMPLETE! Wiring Tower Tech could not be quicker. All sockets are pre-cabled at their origin; the tower needs just two simple operations to be ready for use: (1) multiple power socket cabling, (2) data socket cabling. Another of Tower Tech’s strong points is its easy assembly. A large number of components simply fit H into place, making installation very simple and quick.
“TOWER TECH” SERIES COLUMNS AND TOWERS 45 cm 45850 ▼ GENERAL CHARACTERISTICS • • • • • • • • • • • • Columns/towers for data and power distribution, made with components certified to established regulations; Aluminium frame; Modula kit made in high isolation, tough, long life thermoplastic; Overall dimensions, mm: B=280 x P=280; Height options, mm: 450, 650, 1000.
40800 "TOWER TECH" SERIES MULTIPLE SOCKETS ▼ GENERAL CHARACTERISTICS • • • • • Compliant with CEI 23-50. Ideal for household use, in shops, offices, and trade fairs. High mechanical strength polycarbonate housing. Sockets with openings protected against accidental/intentional contact. Wall mounting option with accessory brackets. ▼ CAUTION 40830 • • • Code Do not install outdoors. Observe the maximum power draw indicated on each unit.
NETWORKING • Networking MICRONET
NETWORKING MICRONET ■ NIC 10/100/1000 24880 24884 APPARATI ATTIVI 2009 2010 92 Code Ident.
■ 10/100 Mbps Switch 24800 Ident. 24800 24801 24802 24805 24806 24807 24808 SP605K SP608K SP608EB SP616B SP616EB SP616R SP624EA 24809 24810 SP624R SP624 24811 SP6052WS 24860 SP608P Description Package 5-Port 10/100M Switch, External Power. Carton 8-Port 10/100M Switch, External Power. Carton 8-Port 10/100M Switch, Internal Power, Metallic Case. Carton 16-Port 10/100M Switch, Desktop, External Power. Carton 16-Port 10/100M Switch, Desktop, Internal power.
■ 10/100/1000 Mbps Gigabit Ethernet Switch 24831 Code Ident. Description 2009 2010 24830 SP665C APPARATI ATTIVI 24834 24831 24832 SP6108 SP676C 24834 SP684C 24835 SP6148WS 5-Port 10/100/1000 Mbps Gigabit Switch, Auto-Uplink, Desktop Size, External Power, Metal. 8-PORT, Unmanaged 10/100/1000M SWITCH. 16-Port 10/100/1000 Mbps Gigabit Web Smart Switch with 4 Shared mini-GBIC Slots, Support 802,1q VLAN,Port Trunk, 802,1P QoS, and SNMPv1 Functions.
■ 10/100/1000 Mbps Manageable Stackable Ethernet Switch (SNMP/RMON/WEB/Telnet) 24845 Code Ident. 24845 SP1678A 24842 M359B 24843 M361 Description 24-Port 10/100M Managed Switch, with 2-Port RJ-45 Gigabit and 2 Shared SFP slots, 802,1q VLAN, 802,3ad LACP, Port Mirror, 802,1d/w Spanning Tree, QoS, 802,1x Authentication, Virtual stacking, SNMP Management. 1000BASE-SX Gigabit Fiber Module for SP1678/SP1678A/SP3516, SC Connector. 100BASE-FX Fiber Module for SP1678, SC Connector.
■ 1000 & 10/100 MEDIA CONVERTER 24870 Code Ident.
■ WIRELESS 2.4 GHz - 54 MB Antenne, Cable and Accessory Code Ident. 24907 24908 24909 24910 24915 24916 24917 SP920LA-12 SP920FB SP920MA-8 SP920MA-12 C920C-10 C920C-5 C925 Description Directional Panel Antenna 12 dBi + cable 1 m + assembly Kit Uni-direction YAGI Antenna, 15 dBi + cable 1 m + assembly Kit Omni-direction Antenna, 8.0 dBi + cable 1 m + assembly Kit Omni-direction Antenna, 12.
■ INTERNET CAMERA Code Ident. 24982 SP5511 24983 SP5511W 24980 SP5521 Description Internet Camera, 1 P. Ethernet 10/100 Mbps Package Pack pcs Carton 1 Wireless 54MB Internet Camera, 1 P. Ethernet 10/100 Mbps Carton 1 Internet Camera, 1 P. Ethernet 10/100 Mbps Carton 1 Carton 1 Internet Camera with PAN/TILT/ZOOM Carton 1 Wireless 54MB Internet Camera with PAN/TILT/ZOOM Carton 1 Dark enviroment 24981 SP5521W Wireless 54MB Internet Camera, 1 P.
INSTRUMENTATION • LAN cable tester • Fusion splicer • Mini OTDR • Measurement instruments
LAN CABLE TESTER ■ LAN Continuity Tester ▼ GENERAL CHARACTERISTICS The LAN Cable Tester – continuity check – is a handy, low cost device for checking the conditions and operation of networks. With its attractive design, it is equipped with a handy case to protect both the main and the remote units. It is specifically designed for fast testing of mapping, polarisation, and continuity of pairs as well as data cable screening (as per EIA/TIA 568A&B).
DATA NETWORK TESTER ■ SIGNALTEK™ cable qualifier ▼ GENERAL CHARACTERISTICS SIGNALTEK™ is the most convenient Gigabit Ethernet tester presently available. To check whether a link is capable of supporting a specific application, it transmits Ethernet packets along the link and measures its capacity in accordance with the Gigabit Ethernet IEEE802.3ab standard – the best performance measure for any network. • Exhaustively tests al data, video and audio applications.
■ Tester for certifying LANTEK 6A, LANTEK 6B & LANTEK 7GB installations ▼ GENERAL CHARACTERISTICS LANTEK® 7G 1 GHz - The first Level IV LAN tester in the world which has been independently verified and is capable of certifying installations up to 1 GHz in excess of CAT 6/ISO-E, CAT 6a and ISO-F specifications. LANTEK® 7G combines the accuracy and bandwidth of a laboratory network analyser with the legendary quality and durability one expects from IDEAL INDUSTRIES, INC LAN certifiers.
▼ TECHNICAL CHARACTERISTICS Description Frequency range CAT 3/5e/6 & ISO-C/D/E support CAT 6a/7 & ISO-F support Duration of CAT 5e test in ... incl. saved results Duration of CAT 6 test in ... incl.
FURUKAWA S122 FUSION SPLICER ▼ GENERAL CHARACTERISTICS Furukawa series S122 splicers with their super-low profile and new generation construction guarantee superior handling and practicality in all conditions and with all types of plant.
PALMTOP OTDR EXFO FTB-200 ▼ GENERAL CHARACTERISTICS • • • • • • • Test recording, data transmission Modules and interfaces can be replaced Accessory connector head inspection kit Lightweight Resistant to impacts, water, dust and solvents Quick, handy software Compliant with GR-196 • • • • Battery life > 8 hours 4 second program startup time Quick data downloads Equipped with upgradable PC software and USB connection • USB A and B and RJ45 ports • Compact Flash memory ▼ SPECIFICATIONS • • • • • Display:
As special order, FANTONET offers customisations of the enclosures listed in our catalogue; contact our technical department directly through the FANTONET CUSTOMER SERVICE +39 049.9597975 - direct.net@fanton.
NOTES 2009 2010 107
NOTES 2009 2010 108
NOTES 2009 2010 109
The strength of innovation Over 50 years of success The Fanton story started in the Fifties, with Mario Fanton at the helm - a story of continual success. In 1975 Mario’s son Renzo restructured the enterprise as a public limited company. It was Renzo Fanton who created the successful brand known today for the functionality, durability and quality of its products. From the idea to the finished product Quality and safety Every successful product is the outcome of a rigorous design and fabrication process.
the company Fanton S.p.A. has a surface area of 30,000 m², of which 20,000 are under cover. It has a highly professional, select workforce, with around 150 employees. Innovation Sales network Automated warehousing Fanton S.p.A. stands out from the competition for its continuous innovation and upgrading of its product line, thus staying ahead of the curve in this challenging market with its highly demanding clientele.
The energyof service... Call Center Visit our website Complete set of catalogues +39.049.9597911 www.fanton.com CD ROM The phone service which is always ready to answer your requests with our courteous, highly expert staff. Monday to Friday, office hours. Our site contains all our catalogues and price lists in Acrobat pdf format for you to download and peruse at your leisure.
...to products Fanton S.p.A. offers a full range of products, from electrical supplies to special cables and cabling systems. The numerous new products introduced in this edition testify to our commitment to continuous improvement in line with the development of the market. Electrical supplies Cabling systems Special cables FME Catalogue FANTONET Catalogue AMBRA 90 CAVI Catalogue FME is Fanton S.p.A.’s historic brand.
Customer service +39 049.9597921 info.export@fanton.com ELECTRICAL S P E C I A L COMPONENTS C A B L E S F A C T O R Y D I V I S I O N C A B L I N G S Y S T E M Viale dell’Industria, 8/10 • 35026 CONSELVE (Padova) ITALY • tel. +39 049 / 95 97 911 • fax +39 049 / 95 97 909 • www.fanton.com • e-mail: commerciale@fanton.