Specifications

21
LAN CABLES
2009
2010
6
7
0
U/UTP Cat. 6
Data transmission cables - gauge AWG 23
Codes A82840 (Box 305m) - A82846 (Coil 500m) - A82847 (Coil 1000m) – PVC
Codes A82940 (Box 305m) - A82946 (Coil 500m) - A82947 (Coil 1000m) – LSZH
Applications:
High frequency data transmission cabling systems.
IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet
Applicable standards:
EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.1
Connection system:
EIA/TIA 568 A and B
Installation:
EN 50174
Directives:
RoHS 2002/95/EC
CONSTRUCTION SPECIFICATIONS
Internal conductor:
Rigid, red copper - nominal gauge AWG 24/1 or 0.51 mm²
Compliant with:
IEC 60228 cl. 1, VDE 0295 cl. 1
Isolation of single conductor:
Polyethylene (PE) thickness 0.98 mm
Classification:
Colours:
Blue+White/Blue, Orange+White/Orange, Green+White/Green, Brown+White/Brown
Separator:
Polyester tape
External sheath and fire behaviour:
Fire retardant polyvinyl chloride (PVC-FR) or Low Smoke Zero Halogen (LSZH)
Classification:
IEC 60332-1 (PVC and LSZH)
CEI 20-22 I CEI 20-35(PVC and LSZH)
CEI 20-37 IEC 60754-1 and 60754-2 IEC 61034 (LSZH)
Colour:
Grey (RAL 7001)
Marking:
FANTONET BY AMBRA90 - dddyy - hh:mm - U/UTP 4 PR AWG 23/1 100 OHM CATEGORY 6E EN
50288-6-1 IEC 60332.1 CM 75°C VERIFIED - m. 000 - (order no.)
LSZH or PVC
Sheath material
m 000
Progressive metre reference
No.
Production lot number
Code Training Nominal external Type of Package Approx.
diameter (mm) package dimensions (mm) weight (kg)
• PVC
A82840 4x2 (4 pairs) AWG 23/1 6.0 mm Box 305 m Dimensions 425x215x425 mm 12 Kg
A82846* 4x2 (4 pairs) AWG 23/1 6.0 mm Coil 500 m Ø400 mm - h 200 mm 19 Kg
A82847 4x2 (4 pairs) AWG 23/1 6.0 mm Coil 1000 m Ø 500 mm - h 300 mm 38 Kg
• LSZH
A82940 4x2 (4 pairs) AWG 23/1 6.0 mm Box 305 m Dimensions 425x215x425 mm 12 Kg
A82946* 4x2 (4 pairs) AWG 23/1 6.0 mm Coil 500 m Ø400 mm - h 200 mm 19 Kg
A82947 4x2 (4 pairs) AWG 23/1 6.0 mm Coil 1000 m Ø 500 mm - h 300 mm 38 Kg
(*) Special order
TRANSMISSIVE SPECIFICATIONS FOR CAT. 6 dB/100.00 m
Frequency Reference value 1.00 4.00 8.00 10.00 16.00 20.00 25.00 31.25 62.50 100.00 155.0 200.0 250.0
Attenuation
Typical 2.0 3.7 5.3 5.9 7.5 8.4 9.5 10.6 15.3 19.8 25.1 28.9 32.8
EIA/TIA 568/B.2 1.6 3.4 4.8 5.4 6.8 7.7 8.6 9.7 13.8 17.6 22.0 24.8 27.9
NEXT
Typical 79.9 70.3 68.8 61.2 67.1 64.8 66.6 63.3 57.3 57.1 55.0 53.9 55.9
EIA/TIA 568/B.2 74.3 65.2 60.7 59.3 56.2 54.7 53.3 51.8 47.3 44.3 41.4 39.7 38.3
ACR
Typical 78.3 67.1 64.2 56.1 60.2 57.0 58.1 54.3 44.4 40.7 32.5 28.9 29.1
EIA/TIA 568/B.2 72.2 61.4 55.4 53.3 48.6 46.3 43.8 41.2 31.9 24.5 16.2 10.8 5.4
PSNext
Typical 78.0 69.5 66.9 61.0 64.5 62.8 64.4 60.1 55.4 54.3 49.1 49.9 51.9
EIA/TIA 568/B.2 72.3 63.2 58.7 57.3 54.2 52.7 51.3 49.8 45.3 42.3 39.4 37.7 36.3
Return Loss
Typical 27.0 31.1 34.0 34.6 33.9 33.9 40.1 42.3 32.4 31.8 30.5 29.1 36.3
EIA/TIA 568/B.2 20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 19.0 18.0 17.3
ELECTRICAL SPECIFICATIONS
Impedance:
100 ± 15 (Ω)
Capacitance pF/m:
5.36 (pF/m)
Conductor DC resistance (at 20°C):
82.8 (Ω/Km)
MECHANICAL SPECIFICATIONS
Operating temperature:
-15°C ÷ +70°C
Installation temperature:
-5°C ÷ +50°C
Storage temperature:
-15°C ÷ +70°C
Minimum bending radius:
8 x cable diameter (mm)
Maximum pulling strain:
70 (N/mm
2
)