Specifications

37
OPTICAL FIBRE CABLES
2009
2010
Multitube optical fibre
24/144 fibre Steel reinforced For outdoors or underground
installation
Data transmission optical fibre cables OM1 OM2 OM3 OS1 (multimode and singlemode)
DESCRIPTION
Reinforced multitube cables are suited for outdoors and directly underground installation, with polyethylene jacket. The reinforcement
is composed of a corrugated steel tube waterproofed with a tape. The fibres are available according to colour standards, with 250 mi-
cron coloured sheaths. The fibres are contained in six PTB tubes, filled with GEL. Due to its construction, this cable has a high resist-
ance to impact and is very waterproof. The optical fibres are available in all four standard homologated versions: MultiMode OM1,
OM2, OM3, and SingleMode OS1.
CHARACTERISTICS
Coloured fibres for quick identification
Rip cord for quick stripping
PE jacket
High mechanical strength
High degree of waterproofing
APPLICATION
Black colour for outdoors or directly underground installation.
CODICE COLORAZIONE
PHYSICAL SPECIFICATIONS
Physical characteristics Traction resistance Bending radius
Number Cable diameter Cable weight Brief traction Prolonged traction Bending radius during Bending radius when
of fibres (mm) (kg/km) resistance (N) resistance (N) installation (cm) installed (cm)
6 fibre sub-unità
24 10.5 126 3000 1000 20 x D 10 x D
48 13.6 130 3000 1000 20 x D 10 x D
96 16.8 190 3000 1000 20 x D 10 x D
144 16.8 260 3000 1000 20 x D 10 x D
OPTICAL SPECIFICATIONS
OM1 OM2 OM3 OS1
62.5/125 microns 50/125 microns 50/125 microns 9/125 microns
(850/1300) (850/1300) (850/1300) (1310/1550)
Attenuation (dB/Km) 2.8/0.8 2.8/0.8 2.7/0.7 0.38/0.24
Minimum bandwidth (MHz/Km) 200/500 500/500 1500/1500
Primary coating dia. (micron) 250 250 250 250
SPECIFICATIONS OF USE
Strength members Two, steel
Crush Test 3000 N
Reinforcement Steel tube with glass fibre
Central filling
Storage temperature - 40° to + 70°C
Installation temperature - 20° to + 60°C
Operating temperature - 20° to + 60°C
Flame resistance
Fire resistance
Special order only - Minimum order 1000m
A PE jacket
B Steel reinforcement
C Waterproof coating
D Tape
E Parallel steel wires
F Reinforcement central filler
G Waterproof gel
H Optical fibre
I Glass fibres
L PBT tube