Specifications

2009
2010
84
MPO SYSTEM
MPO SYSTEM
INTRODUCTIONS
Easy and quickly plug and play fibre optic connection system.
MPO System
Code Description Package Pack Pcs
Code on request MPO Cable12 F. MM 50/125 Mt. Xx
Code on request MPO Cable 12 F. SM 9/125 Mt. Xx
24182 MPO Fan-Out m MM 12 SC 50/125 Carton 1
24186 MPO Fan-Out m MM 12 FC 50/125 Carton 1
24184 MPO Fan-Out m MM 12 LC 50/125 Carton 1
24183 MPO Fan-Out m SM 12 SC 9/125 Carton 1
24187 MPO Fan-Out m SM 12 FC 9/125 Carton 1
24185 MPO Fan-Out m SM 12 LC 9/125 Carton 1
24190 MPO socket Carton 1
24191 MPO Open frame 1 U. for tree box Carton 1
24192 MPO Box MM 12 SC Carton 1
24193 MPO Box MM 12 LC Carton 1
24194 MPO Box MM 24 SC Carton 1
24195 MPO Box SM 12 SC Carton 1
24196 MPO Box SM 12 LC Carton 1
24184
MPO Cable
24182
24190
MAX ATTENUATION
St. ISO/IEC 11801
MULTIMODE SINGLEMODE
Parameters
850 nm
1300 nm 1310 nm 1550 nm
Fibre α
Attenuation dB/km
3.5 max 1.5 max 1.0 max 1.0 max
Connector A
c
Insertion loss dB
0.75 max 0.75 max 0.75 max 0.75 max
Splice A
g
Loss dB
0.3 max 0.3 max 0.3 max 0.3 max
Standard TIA 568B E ISO/IEC 11801 - 2ª Ed.
OPTICAL LINK
ATTENUATION DB MAX
Cabling
Subsystem
Link Length max
MULTIMODE SINGLEMODE
850 nm 1300 nm 1310 nm 1550 nm
Horizontal
100 m 2.5 2.2 2.2 2.2
Building
Backbone
500 m 3.9 2.6 2.7 2.7
Building
OF 300
300 m 2.55 1.95 1.8 1.8
Campus
Backbone
15300 m 7.4 3.6 3.6 3.6
OF 500
Campus
500 m 3.25 2.25 2.0 2.0
OF 2000
Campus
2000 m 8.5 4.5 3.5 3.5