Microscan Symbol Quality Output
Microscan Symbol Quality Output
Percent Cell Damage (Data Matrix Only)
Total Read Time
Capture Time
Locate Time
Definition: When this feature is enabled, the cell damage percentage is appended to
data output.
Serial Cmd: <K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: The time that transpires between the image capture and the output of the
decoded data, including locate time.
When enabled, the total read time is appended to the symbol data.
Serial Cmd: <K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Capture time (in milliseconds) is a fixed “overhead” that includes the time
of capture and transfer of the image.
When enabled, the capture time is appended to the symbol data.
Serial Cmd: <K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: The time in milliseconds from the start of image processing until the
symbol has been located and is ready to be decoded.
When enabled, the locate time is appended to the symbol data.
Serial Cmd: <K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Default: Disabled
Options: 0 = Disabled 1 = Enabled